X-ray fluorescence microtomography analysis of breast tissue samples under various excitation conditions

被引:0
|
作者
Pereira, Gabriela R. [1 ]
Rocha, Henrique S. [1 ]
Anjos, Marcelino J. [1 ]
Lopes, Ricardo T. [1 ]
Faria, Paulo [2 ]
Perez, Carlos A. [3 ]
机构
[1] Nucl Instrumentat Lab, Rio De Janeiro, RJ, Brazil
[2] Inst Nacl Canc, Rio De Janeiro, RJ, Brazil
[3] Brazilian Synchrotron, Campinas, SP, Brazil
关键词
X-ray fluorescence; microtomography; breast tissue; synchrotron radiation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The fluorescence mapping of iron, copper and zinc can be very important in diagnoses, because the biochemistry of these elements suggests that these metals may play an important role in carcinogenesis. However, until now the evidence linking iron, copper and zinc to cancer is far from being conclusive and further research is needed. This work presents a development system to study fluorescence microtomography at the X-Ray Fluorescence Facility (D09B-XRF) at the Brazilian Synchrotron Light Laboratory (LNLS), Campinas, Brazil. A white beam (423 keV), a monochromatic beam produced by a Si (111) at 9.8 keV and a quasi-monochromatic beam produced by a multilayer monochromator at 12 keV were used to sample excitation. The fluorescence photons were collected with an energy dispersive HPGe detector placed at 90 degrees to the incident beam, while transmitted photons were detected with a fast scintillation counter placed behind the sample on the beam direction. In order to find an improved diagnostic technique for a cancer and other diseases using fluorescence mapping of iron, copper and zinc, breast tissue samples and reference samples made of polyethylene and standard solutions were analyzed. The elemental map of iron, copper and zinc were obtained by non-destructive X-Ray fluorescence microtomography.
引用
下载
收藏
页码:249 / 252
页数:4
相关论文
共 50 条
  • [21] X-ray fluorescence elemental imaging, and micro analysis of plant tissue samples
    Fittschen, Ursula
    Hoehner, Ricarda
    Tramel, Wilson
    Fittschen, Andreas
    Kunz, Hans Henning
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [22] Combined imaging system for X-ray fluorescence and transmission X-ray microtomography
    Ohigashi, T
    Watanabe, N
    Yokosuka, H
    Aoki, S
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 1352 - 1355
  • [23] Role of X-ray microtomography in tissue engineering
    Barbetta, Andrea
    Bedini, Rossella
    Pecci, Raffaella
    Dentini, Mariella
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 10 - 18
  • [24] TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS OF LIGHT-ELEMENTS UNDER VARIOUS EXCITATION CONDITIONS
    STRELI, C
    WOBRAUSCHEK, P
    LADISICH, W
    REIDER, R
    AIGINGER, H
    X-RAY SPECTROMETRY, 1995, 24 (03) : 137 - 142
  • [25] X-ray fluorescence and energy dispersive X-ray diffraction for the characterisation of breast tissue
    Geraki, K
    Farquharson, M
    Bradley, D
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 969 - 970
  • [26] X-ray Microtomography of Collagen and Polylactide Samples in Liquids
    Hannula, M.
    Haaparanta, A. -M.
    Tamminen, I.
    Aula, A.
    Kellomaki, M.
    Hyttinen, J.
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 420 - 424
  • [27] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    O. I. Efimova
    A. S. Khlebnikov
    R. A. Senin
    P. A. Voronin
    K. V. Anokhin
    Bulletin of Experimental Biology and Medicine, 2013, 155 : 413 - 416
  • [28] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    Efimova, O. I.
    Khlebnikov, A. S.
    Senin, R. A.
    Voronin, P. A.
    Anokhin, K. V.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2013, 155 (04) : 413 - 416
  • [29] X-ray fluorescence microtomography with a Wolter mirror system
    Watanabe, N
    Yamamoto, K
    Takano, H
    Ohigashi, T
    Yokosuka, H
    Aota, T
    Aoki, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 837 - 840
  • [30] X-ray fluorescence analysis by multiple-glancing X-ray beam excitation
    Tsuji, K
    Sato, T
    Wagatsuma, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1998, 37 (10): : 5821 - 5822