Accuracy of marginal fit and axial wall contour for lithium disilicate crowns fabricated using three digital workflows

被引:27
|
作者
Sadid-Zadeh, Ramtin [1 ]
Katsavochristou, Anastasia [1 ]
Squires, Taylor [2 ]
Simon, Michael [2 ]
机构
[1] SUNY Buffalo, Sch Dent Med, Dept Restorat Dent, 215 Squire Hall, Buffalo, NY 14214 USA
[2] SUNY Buffalo, Sch Dent Med, Buffalo, NY USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2020年 / 123卷 / 01期
关键词
CHAIRSIDE CAD/CAM SYSTEMS; FILM THICKNESS; RESTORATIONS; IMPRESSIONS; SOLUBILITY; RETENTION; FITNESS; RESIN;
D O I
10.1016/j.prosdent.2018.11.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Comparative assessment of the effectiveness of computer-aided design and computer-aided manufacturing (CAD-CAM) technologies used to fabricate complete-coverage restorations is needed. A quantitative assessment requires precise documentation of the marginal adaptation and external surface contour of fabricated restorations. Limited information is currently available regarding the effects of milling mode on marginal adaptation and reproduction of the external surface contour for CAD-CAM-fabricated restorations. Purpose. The purpose of this in vitro study was to evaluate the outcomes for 3 different digital workflows on the marginal gap and the external surface contour reproducibility of CAD-CAM-fabricated lithium disilicate complete-coverage restorations. Material and methods. Twelve Ivorine molars were prepared to receive lithium disilicate crowns. The preparations were digitally recorded using 2 intraoral scanners (TRIOS 3; 3Shape A/S and Planmeca PlanScan; E4D Technologies), and the restorations were designed using their associated design software with reference to the anatomy of an unprepared tooth. The designed restorations were then manufactured from lithium disilicate blocks using a 3-axis milling machine. Twelve restorations were manufactured using the detailed mode (Planmeca PlanScan detailed mode [PPD-D]), and 12 using the standard mode for the Planmeca system (Planmeca PlanScan standard mode [PPD-S]). Restorations from the 3Shape system were fabricated using the detailed mode (TRIOS 3Shape detailed mode [T35-D]). The restorations were secured on their associated preparation with an elastomeric material. The marginal gap of each restoration was then measured in the lmageJ software using images captured by a stereo microscope at x20 magnification. External surface reproducibility was evaluated by measuring undercut at 4-line angles using a dental surveyor. Differences in the marginal gaps of restorations fabricated using the 3 different workflows were compared by Brown-Forsythe robust ANOVA, followed by a post hoc test (alpha=.05). Chi-square analysis (alpha=.05) was used to evaluate differences in the contours of the external surface of the restorations, resistance form, and marginal integrity produced using the 3 workflows. Results. The mean marginal gap for restorations fabricated using the T3S-D workflow was 60 mu m, a distance significantly lower (P<.05) than that of PPD-D and PPD-S workflows, which yielded a marginal gap of 95 mu m for the detailed mode and 124 lim for the standard mode of milling. Restorations fabricated using PPD-D and PPD-S workflows produced a significantly more reproducible external surface contour than those fabricated using the T3S-D workflow. Conclusions. Restorations fabricated using the T3S-D workflow produced the smallest marginal gap. However, reproducibility of the external surface contour for this workflow was the worst of the three workflows analyzed.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 50 条
  • [31] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [32] Effect of conventional and digital fabrication techniques on marginal and internal fit of lithium disilicate endocrowns
    Duygu Ece Keskin
    Gaye Sağlam
    Şükriye Ece Geduk
    BMC Oral Health, 25 (1)
  • [33] Does Resin Cement Type and Cement Preheating Influence the Marginal and Internal Fit of Lithium Disilicate Single Crowns?
    Samy, Nourhan
    Al-Zordk, Walid
    Elsherbini, Ahmed
    Ozcan, Mutlu
    Sakrana, Amal Abdelsamad
    MATERIALS, 2022, 15 (02)
  • [34] Evaluation of Internal Fit and Marginal Adaptation of Provisional Crowns Fabricated with Three Different Techniques
    Wu, Jie
    Xie, Hongjun
    Sadr, Alireza
    Chung, Kwok-Hung
    SENSORS, 2021, 21 (03) : 1 - 15
  • [35] Comparison of the Accuracy of Fit of Metal, Zirconia, and Lithium Disilicate Crowns Made from Different Manufacturing Techniques
    Al Hamad, Khaled Q.
    Al Quran, Firas A.
    AlJalam, Sendos A.
    Baba, Nadim Z.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (05): : 497 - 503
  • [36] Fit Accuracy of Pressed and Milled Lithium Disilicate Inlays Fabricated From Conventional Impressions or a Laboratory-Based Digital Workflow
    Homsy, Foudda
    Bottin, Matteo
    Ozcan, Mutlu
    Majzoub, Zeina
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2019, 27 (01): : 18 - 25
  • [37] 3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions
    Anadioti, Evanthia
    Aquilino, Steven A.
    Gratton, David G.
    Holloway, Julie A.
    Denry, Isabelle
    Thomas, Geb W.
    Qian, Fang
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08): : 610 - 617
  • [38] Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems
    Ferrairo, Brunna Mota
    Piras, Fernanda Furtado
    Lima, Feranda Ferruzzi
    Honorio, Heitor Marques
    Hungaro Duarte, Marco Antonio
    Sanches Borges, Ana Flavia
    Rubo, Jose Henrique
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (04) : 2029 - 2036
  • [39] Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems
    Brunna Mota Ferrairo
    Fernanda Furtado Piras
    Feranda Ferruzzi Lima
    Heitor Marques Honório
    Marco Antonio Hungaro Duarte
    Ana Flávia Sanches Borges
    José Henrique Rubo
    Clinical Oral Investigations, 2021, 25 : 2029 - 2036
  • [40] The marginal gaps of sequentially milled lithium disilicate crowns using two different milling units
    Tan, K.
    Dudley, J.
    AUSTRALIAN DENTAL JOURNAL, 2022, 67 (03) : 239 - 248