Accuracy Profile Theory for the Validation of an LC-MS-MS Method for the Determination of Risperidone and 9-Hydroxyrisperidone in Human Plasma

被引:8
|
作者
Zhang, Xianhua [1 ]
Zhao, Xia [2 ]
Zhang, Chao [1 ]
Yang, Li [1 ]
Xiong, Xin [1 ]
Zhou, Yong [1 ]
Yang, Yiheng [1 ]
Duan, Jingli [1 ]
机构
[1] Peking Univ, Hosp 3, Dept Pharm, Beijing 100191, Peoples R China
[2] Peking Univ, Hosp 1, Dept Pharm, Beijing 100034, Peoples R China
关键词
Column liquid chromatography; Tandem mass spectrometry; Measurement uncertainty; Risperidone and 9-hydroxyrisperidone; PERFORMANCE LIQUID-CHROMATOGRAPHY; QUANTITATIVE ANALYTICAL PROCEDURES; PRESSURE CHEMICAL-IONIZATION; MASS-SPECTROMETRY; MEASUREMENT UNCERTAINTY; METABOLITE; 9-HYDROXYRISPERIDONE; ATYPICAL ANTIPSYCHOTICS; SFSTP PROPOSAL; SERUM; QUANTIFICATION;
D O I
10.1365/s10337-010-1580-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and specific LC-MS-MS method is described for the simultaneous quantification of risperidone and 9-hydroxyrisperidone in human plasma. After extraction with tert-butyl methyl ether, plasma samples were separated on an Atlantis HILIC Silica C18 column (4.6 x 150 mm, 5 mu m)with a mobile phase of ammonium formate buffer (10 mM, pH 4.0)/acetonitrile (40/60, v/v). Detection was by MS-MS. The method was fully validated according to the accuracy profile theory. It is based on beta-expectation tolerance interval for the total measurement error which includes trueness and intermediate precision. The measurement uncertainty derived from beta-expectation tolerance interval was estimated at each of the validation standards. The linearity fitted well over the range of 0.11-26.75 ng mL(-1) for risperidone with an LLOQ of 0.11 ng mL(-1), and for 9-hydroxyrisperidone, at a range of 0.15-37.8 ng mL(-1) with an LLOQ of 0.15 ng mL(-1). The intra- and inter-batch precision of risperidone were < 5.71 and 8.22%, respectively. For 9-hydroxyrisperidone, the data were 5.78 and 6.48%. The recoveries were 88.78% (risperidone) and 70.35% (9-hydroxyrisperidone). The developed method was applied to a pharmacokinetic study of risperidone.
引用
收藏
页码:1015 / 1023
页数:9
相关论文
共 50 条
  • [1] Accuracy Profile Theory for the Validation of an LC–MS-MS Method for the Determination of Risperidone and 9-Hydroxyrisperidone in Human Plasma
    Xianhua Zhang
    Xia Zhao
    Chao Zhang
    Li Yang
    Xin Xiong
    Yong Zhou
    Yiheng Yang
    Jingli Duan
    Chromatographia, 2010, 71 : 1015 - 1023
  • [2] Determination of risperidone and enantiomers of 9-hydroxyrisperidone in plasma by LC-MS/MS
    Cabovska, B.
    Cox, S. L.
    Vinks, A. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 497 - 504
  • [3] The Validation of an LC-MS Method for the Determination of Risperidone and its Active Metabolite 9-Hydroxyrisperidone in Human Plasma
    Li Zhang
    Zheng Jiao
    Zouqing Yao
    Yan Zhong
    Mingkang Zhong
    Yunqiu Yu
    Chromatographia, 2005, 61 : 245 - 251
  • [4] The validation of an LC-MS method for the determination of risperidone and its active metabolite 9-hydroxyrisperidone in human plasma
    Zhang, L
    Jiao, Z
    Yao, ZQ
    Zhong, Y
    Zhong, MK
    Yu, YQ
    CHROMATOGRAPHIA, 2005, 61 (5-6) : 245 - 251
  • [5] Validated LC-MS/MS methods for the determination of risperidone and the enantiomers of 9-hydroxyrisperidone in human plasma and urine
    De Meulder, Marc
    Remmerie, Bart M. M.
    de Vries, Ronald
    Sips, Luc L. A.
    Boom, Sandra
    Hooijschuur, Edwin W. J.
    van de Merbel, Nico C.
    Timmerman, Philip M. M. B. L.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01): : 8 - 16
  • [6] Development and validation of an LC-MS-MS method for the determination of terfenadine in human plasma
    Xu, A
    Linderholm, K
    Peng, L
    Hulse, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (12) : 1675 - 1680
  • [7] A fast DLLME-LC-MS/MS method for risperidone and its metabolite 9-hydroxyrisperidone determination in plasma samples for therapeutic drug monitoring of patients
    Steinhorst Alcantara, Greyce Kelly
    Calixto, Leandro Augusto
    Rocha, Bruno Alves
    Barbosa Junior, Fernando
    Moraes de Oliveira, Anderson Rodrigo
    de Gaitani, Cristiane Masetto
    MICROCHEMICAL JOURNAL, 2020, 156
  • [8] LC-MS-MS Method for Determination of Metolazone in Human Plasma
    Roy, Shikha M. N.
    Mangaonkar, Kiran V.
    Yetal, Santosh M.
    Joshi, Santosh. S.
    E-JOURNAL OF CHEMISTRY, 2008, 5 (03) : 634 - 640
  • [9] Sensitive LC-MS-MS method for the determination of tiopronin in human plasma
    Jiang, Bo
    Xu, Yu
    Xu, Fang
    Sun, Junjie
    Li, Na
    Luo, Yanan
    Guo, Qingxiang
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (06) : 655 - 662
  • [10] LC-MS-MS Development and Validation for Quantitative Determination of Methoxsalen in Human Plasma
    Gomes, Noel Alex
    Vaidya, Vikas V.
    Pudage, Ashutosh M.
    Joshi, Santosh S.
    Laud, Avdhoot M.
    Basagare, Snehal
    Tandel, Jayram A.
    CHROMATOGRAPHIA, 2009, 69 (9-10) : 1061 - 1065