Smokeless tobacco analysis: Simultaneous extraction and purification of alkaloids, volatile N-nitrosamines, and polycyclic hydrocarbons for GC-MS/MS

被引:5
|
作者
Wang, Xiaoyu [1 ]
Qin, Yaqiong [1 ]
Nie, Cong [1 ]
Guo, Junwei [1 ]
Pan, Lining [1 ]
Xie, Fuwei [1 ]
Wang, Sheng [1 ]
Wang, Bing [1 ]
Zhao, Xiaodong [1 ]
Wang, Baolin [2 ]
Jia, Guotao [2 ]
机构
[1] Zhengzhou Tobacco Res Inst CNTC, Zhengzhou 450001, Peoples R China
[2] Res Inst CNTC, Ctr Technol, China Tobacco Henan Ind Co Ltd, Zhengzhou, Peoples R China
关键词
Alkaloids; Polycyclic aromatic hydrocarbons; Simultaneous extraction; Smokeless tobacco product; Volatile nitrosoamines; SOLID-PHASE EXTRACTION; AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; CHEMICAL-CHARACTERIZATION; PRODUCTS; NICOTINE;
D O I
10.1002/jssc.202100186
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several smokeless tobacco products are available in the market and comprise complex chemical matrices. Sample preparation for analysis of the multiple classes of harmful compounds in smokeless tobacco products is highly cumbersome. In this study, a simultaneous extraction scheme was developed for three toxic analyte classes in smokeless tobacco products using a two-phase solution consisting of 5% aqueous NaOH and dichloromethane in a 1:4 ratio. The dichloromethane extract was used to analyze four alkaloids directly at levels greater than parts per million; however, passing the layer through a silica cartridge for further purification and concentration was necessary for determining 18 polycyclic aromatic hydrocarbons and four volatile N-nitrosoamines at the ppt level. The multitargets were determined by using gas chromatography with tandem mass spectrometry. The limits of detection for the 18 polycyclic aromatic hydrocarbons, four volatile N-nitrosoamines, three minor alkaloids, and nicotine were 0.2-1.2, 0.2-0.4, 0.6-1.0, and 10.2 mu g/g, respectively. Four different smokeless tobacco substrates were fortified with three levels of mixed standards, and the recoveries ranged between 83 and 110%. The method was highly efficient, reduced the sample amounts, solvents, and the time required by approximately 60%. The method was used to assay 18 smokeless tobacco products, and showed potentials in assaying drugs and other plant-based substrates.
引用
收藏
页码:2642 / 2654
页数:14
相关论文
共 50 条
  • [41] GC-MS analysis of polycyclic aromatic hydrocarbons in bottled olive oil marketed in Lebanon
    Elaridi, Jomana
    Fakhro, Maysa
    Yamani, Osama
    Dimassi, Hani
    Othman, Hiba
    Attieh, Zouhair
    TOXICOLOGICAL RESEARCH, 2020, 36 (03) : 211 - 220
  • [42] Determination of 18 polycyclic aromatic hydrocarbons in edible oils by isotope dilution GC-MS/MS
    Beijing Key Laboratory of Environmentally Harmful Chemical Analysis, Beijing University of Chemical Technology, Beijing
    100029, China
    不详
    100013, China
    J. Chin. Mass Spectrom. Soc., 2 (120-127):
  • [43] Analysis of Tobacco-Specific Nitrosamines in Cigarette Tobacco, Cigar Tobacco, and Smokeless Tobacco by Isotope Dilution LC-MS/MS
    Wu, Jingcun
    LCGC NORTH AMERICA, 2020, 38 (10) : 559 - 568
  • [44] Determination of Polycyclic Aromatic Hydrocarbons in Industrial Harbor Sediments by GC-MS
    Dong, Cheng-Di
    Chen, Chih-Feng
    Chen, Chiu-Wen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2012, 9 (06): : 2175 - 2188
  • [45] Simultaneous determination of polycyclic aromatic hydrocarbons and polychlorinated biphenyls in Pu-erh tea by dispersive solid-phase extraction coupled with GC-MS/MS
    Fei, Zhixin
    Liu, Min
    Jiang, Qian
    Liu, Yang
    Bi, Zenghui
    Song, Qing
    Duan, Yihong
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 123
  • [46] Analysis method of N-nitrosamines in human urine by LC-MS/MS system
    Park N.-Y.
    Jung W.
    Kho Y.
    Kho, Younglim (ylkho@eulji.ac.kr), 2017, Korean Chemical Society (61): : 51 - 56
  • [47] Rapid determination of nine N-nitrosamines in dry-cured mackerel (Scomberomorus niphonius) using salting out homogeneous phase extraction with acetonitrile followed by GC-MS/MS
    Dong, Hao
    Li, Haixia
    Liang, Ming
    Luo, Donghui
    Liu, Guang
    Zeng, Xiaofang
    Bai, Weidong
    Yang, Juan
    Xian, Yanping
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2020, 130
  • [48] GC determination of N-nitrosamines by supersonic molecular beam MS equipped with triple quadrupole analyzer, GC/SMB/QQQ/MS
    Anna, Voloshenko
    Rimma, Shelkov
    Ovadia, Lev
    Jenny, Gun
    ANALYTICA CHIMICA ACTA, 2011, 685 (02) : 162 - 169
  • [49] Analysis of Amaryllidaceae alkaloids in Galanthus krasnovii by GC-MS
    Emir, A.
    Emir, C.
    Bozkurt, B.
    Kaya, G., I
    Eminagaoglu, O.
    Onur, M. A.
    Somer, N. U.
    PLANTA MEDICA, 2015, 81 (16) : 1540 - 1540
  • [50] Use of Automated Solid-Phase Extraction and GC-MS/MS to Evaluate Nitrosamines in Water Matrices
    Holady, Janie C.
    Trenholm, Rebecca A.
    Snyder, Shane A.
    AMERICAN LABORATORY, 2012, 44 (03) : 25 - 30