Headless self-compressing cannulated screw fixation for treatment of radial carpal bone fracture or fissure in dogs

被引:8
|
作者
Perry, K. [1 ]
Fitzpatrick, N. [1 ]
Johnson, J. [1 ]
Yeadon, R. [1 ]
机构
[1] Fitzpatrick Referrals, Godalming GU7 2QQ, Surrey, England
关键词
Acutrak; radial carpal bone; scaphoid; compression screw; carpal arthroscopy; HUMERAL CONDYLAR FRACTURE; SCAPHOID WAIST FRACTURES; INCOMPLETE OSSIFICATION; DORSAL APPROACH; PERCUTANEOUS FIXATION; INTERNAL-FIXATION; NONUNION; LUXATION; GRAFTS; ARTERY;
D O I
10.3415/VCOT-09-01-0006
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objectives: To report the application and clinical outcome of the treatment of radial carpal bone fracture in five dogs using a variably-pitched, headless cannulated compression screw (Acutrak (R)). Methods: Arthroscopy was performed prior to surgical repair in three cases. In two cases, a fissure within the radial carpal bone was more clearly apparent when oblique indirect illumination was employed at arthrotomy. Following Acutrak (R) screw placement via arthrotomy, external coaptation was applied in all cases for a period of two weeks. Results: Five dogs were treated, of which four were Boxers, and one was a Labrador Retriever crossbreed. All dogs were lame prior to treatment. There was no history of trauma, and all dogs had soft tissue swelling on the dorsal aspect of the radiocarpal joint. In all cases the fissure or fracture line was oblique in orientation, extending disto-medially from the midpoint of the radiocarpal joint proximally to the level of the second carpal bone distally. All fractures treated demonstrated progressive radiographic healing, and all dogs were free of lameness at six weeks post-operatively, but two of the five fractures failed to reach complete radiographic union. All dogs remained lameness-free with mean follow-up of 12.5 months. Discussion: Acutrak (R) screws are headless devices which achieve compression, even in small bone fragments. Threads engage both the near and far fracture segments, leading to increased screw-bone contact which maximizes pull-out strength and may increase the fatigue strength of the screw. Clinical significance: Fixation of two-piece canine radial carpal-bone fractures with the Acutrak (R) screw proved a reliable alternative to conventional compression screw fixation, and may have benefits over alternatives attributable to screw design and application technique.
引用
收藏
页码:94 / 101
页数:8
相关论文
共 50 条
  • [21] Application of Robot Positioning for Cannulated Screw Internal Fixation in the Treatment of Femoral Neck Fracture: Retrospective Study
    Wan, Lei
    Zhang, Xiangyun
    Wu, Dalong
    Li, Zhihao
    Yuan, Dongtao
    Li, Junming
    Zhang, Shikui
    Yue, Long
    Zhang, Shao'an
    JMIR MEDICAL INFORMATICS, 2021, 9 (01)
  • [22] Antegrade anterior column acetabulum fracture fixation with cannulated compression headless screws-A biomechanical study on standardized osteoporotic artificial bone
    Berk, Till
    Zderic, Ivan
    Schwarzenberg, Peter
    Pastor, Torsten
    Drenchev, Ludmil
    Skulev, Hristo Kostov
    Richards, Geoff
    Hierholzer, Christian
    Halvachizadeh, Sascha
    Pape, Hans-Christoph
    Gueorguiev, Boyko
    PLOS ONE, 2024, 19 (06):
  • [23] The treatment of calcaneal fracture with percutaneous poking reduction through the gap of fractures and internal fixation with cannulated screw
    Zhang Hanqing
    Xiao Man
    Yu Zuguang
    Liang Bo
    Wang Ke
    Yang Yang
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 127 : 50 - 50
  • [24] The use of fully threaded headless cannulated screws for femoral neck fracture fixation in small-breed dogs show promise in cadaveric study
    Kim, Sorin
    Cha, Gyuwon
    Kim, Jooyoung
    Cho, Jun-Sik
    Kim, Hwi-Yool
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2024, 85 (10)
  • [25] Treatment of unstable scaphoid waist nonunion with cancellous bone grafts and cannulated screw or Kirschner wire fixation
    Hegazy, Galal
    Seddik, Mahmoud
    Abd-Elghany, Tharwat
    Abdelaal, Mohamed
    Abdelaziz, Mohamed
    Elzahed, Ehab
    Saqr, Yasser
    Seif, Elsayed
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2021, 55 (03) : 167 - 172
  • [26] Surgical treatment for distal clavicle fracture associated with coracoclavicular ligament rupture using a cannulated screw fixation technique
    Jin, Cheng Zhe
    Kim, Hyun-Kon
    Min, Byoung-Hyun
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 60 (06): : 1358 - 1361
  • [27] Clinical evaluation of a titanium, headless variable-pitched tapered cannulated compression screw for repair of frontal plane slab fractures of the third carpal bone in thoroughbred racehorses
    Hirsch, Jonathan E.
    Galuppo, Larry D.
    Graham, Lindsay E.
    Simpson, Edwin L.
    Ferraro, Gregory L.
    VETERINARY SURGERY, 2007, 36 (02) : 178 - 184
  • [28] TREATMENT OF UNUNITED FRACTURES OF THE CARPAL SCAPHOID BY ILIAC BONE-GRAFTS AND HERBERT SCREW FIXATION
    INOUE, G
    MIURA, T
    INTERNATIONAL ORTHOPAEDICS, 1991, 15 (04) : 279 - 282
  • [29] Clinical Results of Surgical Treatment for Comminuted Radial Head and Neck Fracture: Headless Compression Screws Versus Plate Fixation
    Yano, Koichi
    Fukuda, Makoto
    Uemura, Takuya
    Kaneshiro, Yasunori
    Yamanaka, Kiyotaka
    Teraura, Hidetoshi
    Yamamoto, Ken
    Sasaki, Ryo
    Matsuura, Takeshi
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (02) : 253 - 261
  • [30] Clinical Results of Surgical Treatment for Comminuted Radial Head and Neck Fracture: Headless Compression Screws Versus Plate Fixation
    Koichi Yano
    Makoto Fukuda
    Takuya Uemura
    Yasunori Kaneshiro
    Kiyotaka Yamanaka
    Hidetoshi Teraura
    Ken Yamamoto
    Ryo Sasaki
    Takeshi Matsuura
    Indian Journal of Orthopaedics, 2023, 57 : 253 - 261