Measurement of partial L fluorescence yields of bismuth using synchrotron radiation

被引:3
|
作者
Menesguen, Yves [1 ]
Boyer, Bruno [1 ]
Rodrigues, Matias [1 ]
Lepy, Marie-Christine [1 ]
机构
[1] CEA, LIST, Lab Natl Henri Becquerel, F-91191 Gif Sur Yvette, France
关键词
Bismuth; Mass attenuation coefficients; Fluorescence yields; Synchrotron radiation; Pb-210; Photoionization; L shell; KRONIG TRANSITION-PROBABILITIES; L-SUBSHELL FLUORESCENCE; SHELL COSTER-KRONIG; RANGE; COEFFICIENTS; ELEMENTS; WIDTHS; DECAY; AUGER; RAD;
D O I
10.1016/j.apradiso.2015.11.081
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Tunable monochromatic photon radiation was used to measure transmission of a bismuth target in the energy range from 7 keV to 20 keV. Partial L fluorescence yields of bismuth were obtained by combining measurement of the fluorescence induced by photoionization of the bismuth target and X-rays from the radioactive decay of Pb-210. Several photon energies have been used to successively ionize the L subshells, which allowed detailed analysis of the rearrangement spectra and determination of the X-ray relative intensities of the L-1, L-2 and L-3 series. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [31] SAMPLES FOR X-RAY-FLUORESCENCE ANALYSIS USING SYNCHROTRON RADIATION
    KHVOSTOVA, VP
    TRUNOVA, VA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (1-2): : 295 - 300
  • [32] Measurement of L subshell fluorescence yields of some elements in the atomic range 75≤Z≤92 using photoionization
    Sogut, O.
    Apaydin, G.
    Simsek, O.
    Cengiz, E.
    Saydam, M.
    Kup, N.
    Tirasoglu, E.
    RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (05) : 307 - 310
  • [33] ACCURATE MEASUREMENT OF POWDER DIFFRACTION INTENSITIES USING SYNCHROTRON RADIATION
    PARRISH, W
    HART, M
    AUSTRALIAN JOURNAL OF PHYSICS, 1988, 41 (03): : 403 - 411
  • [34] Measurement of residual stresses in titanium alloys using synchrotron radiation
    Umapathi, A.
    Swaroop, S.
    MEASUREMENT, 2019, 140 : 518 - 525
  • [35] Measurement of vacancy transfer probability from K to L shell using K-shell fluorescence yields
    Söǧüt Ö.
    Büyükkasap E.
    Küçükönder A.
    Tarakçioǧlu T.
    Pramana, 2009, 73 (4) : 711 - 718
  • [36] Measurement of L shell fluorescence yields of some elements in the atomic range 56≤Z≤64 using photoionisation
    Simsek, Ö
    Dogan, O
    Turgut, Ü
    Ertugrul, M
    RADIATION PHYSICS AND CHEMISTRY, 1999, 54 (03) : 229 - 233
  • [37] Measurement of vacancy transfer probability from K to L shell using K-shell fluorescence yields
    Soguet, O.
    Buyukkasap, E.
    Kucukonder, A.
    Tarakcioglu, T.
    PRAMANA-JOURNAL OF PHYSICS, 2009, 73 (04): : 711 - 718
  • [38] X-ray fluorescence analysis using synchrotron radiation (SYXRF)
    Haller, M
    Knochel, A
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (03): : 461 - 488
  • [39] Development of radiation monitors for measurement of synchrotron radiation
    Singh, Sunil K.
    Mahant, A. K.
    Sahu, Abinash
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2012, 50 (11) : 797 - 798
  • [40] L FLUORESCENCE YIELDS IN HEAVY ELEMENTS
    HALLEY, JW
    ENGELKEMEIR, D
    PHYSICAL REVIEW A-GENERAL PHYSICS, 1964, 134 (1A): : A24 - &