Measurement of partial L fluorescence yields of bismuth using synchrotron radiation

被引:3
|
作者
Menesguen, Yves [1 ]
Boyer, Bruno [1 ]
Rodrigues, Matias [1 ]
Lepy, Marie-Christine [1 ]
机构
[1] CEA, LIST, Lab Natl Henri Becquerel, F-91191 Gif Sur Yvette, France
关键词
Bismuth; Mass attenuation coefficients; Fluorescence yields; Synchrotron radiation; Pb-210; Photoionization; L shell; KRONIG TRANSITION-PROBABILITIES; L-SUBSHELL FLUORESCENCE; SHELL COSTER-KRONIG; RANGE; COEFFICIENTS; ELEMENTS; WIDTHS; DECAY; AUGER; RAD;
D O I
10.1016/j.apradiso.2015.11.081
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Tunable monochromatic photon radiation was used to measure transmission of a bismuth target in the energy range from 7 keV to 20 keV. Partial L fluorescence yields of bismuth were obtained by combining measurement of the fluorescence induced by photoionization of the bismuth target and X-rays from the radioactive decay of Pb-210. Several photon energies have been used to successively ionize the L subshells, which allowed detailed analysis of the rearrangement spectra and determination of the X-ray relative intensities of the L-1, L-2 and L-3 series. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [1] Measurement of L subshell fluorescence yields of some rare earth elements using synchrotron radiation
    Krishnananda
    Mirji, Santosh
    Hosamani, Mutturaj
    Badiger, N. M.
    Tiwari, M. K.
    Lodha, G. S.
    X-RAY SPECTROMETRY, 2016, 45 (02) : 72 - 76
  • [2] Measurement of L subshell fluorescence yields of elements in the range 45≤Z≤50 using synchrotron radiation
    Bonzi, E. V.
    Badiger, N. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 248 (02): : 242 - 246
  • [3] Effect of chemical environment on L subshell fluorescence yields using synchrotron radiation
    Krishnananda
    Mirji, Santosh
    Badiger, N. M.
    Tiwari, M. K.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2016, 656 : 357 - 361
  • [4] L-SUBSHELL FLUORESCENCE YIELDS MEASURED WITH SYNCHROTRON-RADIATION
    SANCHEZ, HJ
    RUBIO, M
    PEREZ, RD
    BURATTINI, E
    X-RAY SPECTROMETRY, 1994, 23 (06) : 267 - 271
  • [5] Experimental determination of L subshell fluorescence yields of Ba, La and Pr using synchrotron radiation
    Badiger, NM
    Bonzi, EV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 243 (01): : 34 - 37
  • [6] THE FLUORESCENCE YIELDS OF THE L-LEVELS OF BISMUTH
    ROSS, MAS
    COCHRAN, AJ
    HUGHES, J
    FEATHER, N
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION A, 1955, 68 (07): : 612 - 624
  • [7] Setup for measurements of partial ion yields at the Synchrotron Radiation Center
    Wehlitz, R
    Lukic, D
    Koncz, C
    Sellin, IA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03): : 1671 - 1673
  • [8] Measurement of K fluorescence yields of niobium and rhodium using monochromatic radiation
    Riffaud, Jonathan
    Lepy, Marie-Christine
    Menesguen, Yves
    Novikova, Anastasiia
    X-RAY SPECTROMETRY, 2017, 46 (05) : 341 - 346
  • [9] Measurement of M subshell X-ray fluorescence parameters of gold, lead and bismuth using 7 keV synchrotron radiation
    Hiremath, Gangadharayya B.
    Vinayak, A.
    Hosamani, M. M.
    Badiger, N. M.
    Tiwari, M. K.
    SPECTROSCOPY LETTERS, 2021, 54 (09) : 715 - 722
  • [10] Erbium L-subshell Coster-Kronig and fluorescence yields determination by synchrotron radiation photoionization
    Barrea, RA
    Pérez, CA
    Sànchez, HJ
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2002, 35 (14) : 3167 - 3178