Effect of winglet location on performance of fin-tube heat exchangers with inline tube arrangement

被引:37
|
作者
Naik, Hemant [1 ]
Tiwari, Shaligram [1 ]
机构
[1] Indian Inst Technol Madras, Dept Mech Engn, Madras 600036, Tamil Nadu, India
关键词
Heat exchangers; Inline tube arrangement; Rectangular winglet pair; Common flow down; Secondary flow intensity; LONGITUDINAL VORTEX GENERATORS; TRANSFER ENHANCEMENT; PLATE-FIN; HYDRAULIC PERFORMANCE; PRESSURE-DROP; FLAT-PLATE; OPTIMIZATION; VORTICES; CHANNEL; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2018.04.071
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat transfer performance of fin-tube heat exchangers can be enhanced by introducing longitudinal vortices generated using vortex generators (VGs). Location of VGs with respect to tubes plays major role in deciding the enhancement in heat transfer. Three-dimensional numerical investigations have been carried out to study the effect of winglet location on heat transfer characteristics of fin-tube heat exchangers for inline tube arrangement. In this study, rectangular winglet pair (RWP) type VGs having common flow down configuration are considered. Initially, effect of different possible locations of RWP corresponding to tube centre have been investigated to analyse the heat transfer and flow field characteristics. Further, effects of angle of attack (beta) ranging from 15 degrees to 60 degrees and Reynolds number (Re) in the range from 2000 to 4000 have also been studied for the location associated with maximum heat transfer corresponding to mean values of beta and Re in the considered range. To illustrate the interesting flow features of vortices generated due to placement of RWPs and how those affect heat transfer, streamlines and temperature contours have been investigated. Enhancement in heat transfer has been quantified using Nusselt number while pressure loss is estimated with the help of friction factor. Role of secondary flow induced by RWPs is quantified in terms of secondary flow intensity. Thermal performance factor (JF) is used to evaluate the combined effect of enhancement in heat transfer and increase in pressure drop. For upstream located RWPs, the value of JF is found to be higher due to lower pressure loss as compared to RWPs mounted in other regions. The value of JF is maximum for RWP located at Delta X = -2.0, Delta Y = +/- 1.25 and correspondingly 37.6% enhancement in heat transfer is observed as compared to the case for the arrangement in absence of RWPs. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:248 / 261
页数:14
相关论文
共 50 条
  • [31] Effect of vortex on heat transfer enhancement of fin-tube heat exchanger
    Yoo, SY
    Park, DS
    Chung, MH
    Park, JT
    [J]. HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 674 - 679
  • [32] Freeform winglet design of fin-and-tube heat exchangers guided by topology optimization
    Kobayashi, Hiroki
    Yaji, Kentaro
    Yamasaki, Shintaro
    Fujita, Kikuo
    [J]. APPLIED THERMAL ENGINEERING, 2019, 161
  • [33] Effect of corrosion on performance of fin-and-tube heat exchangers with different fin materials
    Zhao, Yu
    Qi, Zhaogang
    Wang, Qinren
    Chen, Jiangping
    Shen, Jun
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 37 : 98 - 103
  • [34] Effect of vacuum environment on air side heat and mass transfer characters of plain fin-tube heat exchangers
    Zhang Huichen
    Liu Jianhua
    Xu Xiaojin
    Wu Qingqing
    Zhang Liang
    Zhang Jiawen
    Liu Qi
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 188
  • [35] A novel one-dimensional model to predict fin efficiency of continuous fin-tube heat exchangers
    Suarez, Felipe
    Keegan, Sergio D.
    Mariani, Nestor J.
    Barreto, Guillermo F.
    [J]. APPLIED THERMAL ENGINEERING, 2019, 149 : 1192 - 1202
  • [36] Comparative Performance of Rippled Fin Plate Fin and Tube Heat Exchangers
    Maltson, J. D.
    Wilcock, D.
    Davenport, C. J.
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 21 - 28
  • [37] IMPACT OF THE ANTICORROSION FILMS ON THE CONDENSING HEAT TRANSFER OF FLUE GAS IN FIN-TUBE HEAT EXCHANGERS
    Wang Sui-lin
    Wu Yuan-yuan
    Pan Shu Yuan
    Shi Yong Zheng
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 2: CONDENSATION, CONVECTION, MELTING AND SOLIDIFICATION, 2010, : 153 - 159
  • [38] An experimental study on the air side heat transfer performance of the perforated fin-tube heat exchangers under the frosting conditions
    Liu, Xiaoqin
    Yu, Jianlin
    Yan, Gan
    [J]. Applied Thermal Engineering, 2020, 166
  • [39] An experimental-numerical evaluation of thermal contact conductance in fin-tube heat exchangers
    Kim, CN
    Jeong, J
    Youn, B
    Kil, SH
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2003, 46 (02) : 299 - 307
  • [40] Effect of fin pitch and number of tube rows on the air side performance of herringbone wavy fin and tube heat exchangers
    Wongwises, S
    Chokeman, Y
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (13-14) : 2216 - 2231