Technical Study of Turbine Damage for Steam Power Plant

被引:0
|
作者
Winarno, Dheka Bakti Krisnamurti [1 ]
机构
[1] PLN Indonesia, Jakarta, Indonesia
关键词
steam turbine; governor valve; main stop valve; turbine protection; OPC solenoid; AST solenoid; turbine overspeed;
D O I
10.1109/TENSYMP52854.2021.9550925
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Damage to the turbine at the Steam Power Plant (PLTU) Bolok Indonesia began with a 70 kV Bolok - Maulafa conductor disturbance due to a lightning disturbance. All Diesel Engine Power Plants (PLTDs) in the Kupang system have a trip because there is an over current (OCR is working). PLTU Bolok has a trip due to under frequency (UFR is working). The electrical system (medium voltage and low voltage AC) at PLTU Bolok has a loss of power. Uninterruptible Power Supply (UPS) power distribution has a loss of voltage (loss of power). The turbine at PLTU Bolok were damaged at a very severe level, so that the casing was perforated due to overspeed beyond the allowable limit. The turbine overspeed occurs over the tolerance limit because the electrical and mechanical protection (functions to close the MSV and GV) do not work. The design that must be changed to reduce disturbance to the turbine caused by the GV system is the controller design for the GV and the logic design for operating and stopping the High Pressure AC Pump. Meanwhile, the design that must be added is the logic design for operating the turbine protection equipment.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Technical Diagnostics and Adjustment of Steam Turbine Units
    Taradai D.V.
    [J]. Power Technology and Engineering, 2020, 54 (03) : 388 - 393
  • [42] New steam power-generating units. Selection of parameters of steam and their influence on efficiency of steam turbine plant
    Ogurtsov, A.P.
    [J]. Tyazheloe Mashinostroenie, 1996, (08): : 23 - 28
  • [43] Impact of increasing steam turbine flexibility on the annual performance of a direct steam generation tower power plant
    Topel, M.
    Guedez, R.
    Laumert, B.
    [J]. INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 : 1171 - 1180
  • [44] The Effect of the Silica Crust on the Blades on the Efficiency of the Steam Turbine in Geothermal Power Plant
    Achdi, Endang
    Somantri, Herman
    Rahadiana, Regi
    [J]. DISRUPTIVE INNOVATION IN MECHANICAL ENGINEERING FOR INDUSTRY COMPETITIVENESS, 2018, 1983
  • [45] The QDMC Model Predictive Controller for the Nuclear Power Plant Steam Turbine Control
    Sokolski, Pawel
    Rutkowski, Tomasz A.
    Duzinkiewicz, Kazimierz
    [J]. TRENDS IN ADVANCED INTELLIGENT CONTROL, OPTIMIZATION AND AUTOMATION, 2017, 577 : 241 - 250
  • [46] LCA-LCCA of oil fired steam turbine power plant in Singapore
    Kannan, R
    Tso, CP
    Osman, R
    Ho, HK
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (18-19) : 3093 - 3107
  • [47] Optimization and the effect of steam turbine outlet quality on the output power of a combined cycle power plant
    Ganjehkaviri, A.
    Jaafar, M. N. Mohd
    Hosseini, S. E.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 89 : 231 - 243
  • [48] A method of economical load dispatch for steam turbine unit of thermal power plant
    Ran, Jingyu
    Yang, Lin
    Zhang, Li
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (08) : 752 - 764
  • [49] 20 MW STEAM TURBINE POWER PLANT FOR WASTE HEAT RECOVERY.
    Murayama, Noboru
    Yokota, Hiroshi
    Furuya, Kikuo
    Matsuya, Toshifumi
    Murakami, Shigeo
    Shirai, Masaaki
    [J]. Nippon Kokan technical report overseas, 1981, (33): : 51 - 61
  • [50] PERFORMANCE ANALYSIS ON THE HYBRID POWER PLANT OF SOFC AND STEAM INJECTED GAS TURBINE
    Zhang, Wenshu
    Zhang, Huisheng
    Lu, Zhenhua
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 3, 2010, : 653 - 660