Midterm outcome of fourth-generation ceramic-on-ceramic bearing surface in revision total hip arthroplasty

被引:6
|
作者
Chang, Jun-Dong [1 ]
Kim, In-Sung [1 ]
Mansukhani, Sameer Ajit [1 ]
Sharma, Vishwas [1 ]
Lee, Sang-Soo [2 ]
Yoo, Je-Hyun [3 ]
机构
[1] Hallym Univ, Dept Orthopaed Surg, Dongtan Sacred Heart Hosp, 7,Keunjaebong Gil, Hwaseong Si 445907, Gyeonggi Do, South Korea
[2] Hallym Univ, Coll Med, Chuncheon Sacred Heart Hosp, Dept Orthopaed Surg, Chunchon, South Korea
[3] Hallym Univ, Coll Med, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang, Gyeonggi Do, South Korea
关键词
bearing surface; ceramic-on-ceramic; fourth generation; revision; total hip arthroplasty; PERIPROSTHETIC JOINT INFECTION; POLYETHYLENE BEARINGS; MILLION CYCLES; SQUEAKING; COMPLICATIONS; EPIDEMIOLOGY; DISLOCATION; FRACTURES; MECHANISM; LINER;
D O I
10.1177/2309499018783913
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study is to evaluate the clinical and radiologic outcomes after revision total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) bearing surfaces. Methods: A total of 52 revision THAs (28 men and 19 women) using the fourth-gene ration CoC bearing surfaces were retrospectively evaluated. Both acetabular cup and femoral stem were revised in all cases. The mean follow-up period was 7.3 years (range, 4.0-9.9 years). The clinical results with Harris hip score (HHS), Western Ontario McMaster Osteoarthritis Index (WOMAC), and radiologic outcomes were evaluated. Results: At the final follow-up examination, the average HHS was 90.4 (range, 67-100). The average WOMAC pain and physical function score were 2.8 (range, 0-12) and 16.4 (range, 0-42), respectively. Complications were observed in 10 hips (19.2%). However, there were no bearing surface-related complications, and no cases of dislocation and squeaking. Retroacetabular pelvic osteolysis without cup loosening was observed in one hip at the final follow-up. However, no hip showed radiographic signs of cup loosening, vertical or horizontal acetabular cup migrations, and changes of inclinations during the follow-up period. Conclusion: Our data showed that clinical and radiologic outcomes after revision THA using fourth-generation CoC bearing were favorable. Hence, revision THA with the use of CoC bearing surfaces can be preferentially considered. Further studies with long-term follow-up data are warranted.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Ceramic-on-Ceramic Total Hip Arthroplasty: The USA Experience
    Garino, J. P.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 95 - 100
  • [32] Modern ceramic-on-ceramic bearings in total hip arthroplasty
    Nau, Thomas
    Raschid, Josef
    Kirnbauer, Werner
    Schwischei, Harald
    Ehall, Reinhard
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 2005, 155 (3-4) : 70 - 74
  • [33] Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty (THA)
    Sentuerk, U.
    Perka, C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (02): : 198 - 202
  • [34] Analysis of a retrieved squeaking ceramic-on-ceramic hip arthroplasty bearing
    Sidebottom, Mark
    Allan, D. Gordon
    Paliwal, Manish
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (13) : 2373 - 2383
  • [35] Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review
    Chen-Chen Zhao
    Guo-Xin Qu
    Shi-Gui Yan
    Xun-Zi Cai
    Journal of Orthopaedic Surgery and Research, 13
  • [36] Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review
    Zhao, Chen-Chen
    Qu, Guo-Xin
    Yan, Shi-Gui
    Cai, Xun-Zi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [37] Are Ceramic-on-ceramic Bearings in Total Hip Arthroplasty Associated With Reduced Revision Risk for Late Dislocation?
    Pitto, Rocco P.
    Garland, Mikaela
    Sedel, Laurent
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (12) : 3790 - 3795
  • [38] Ceramic-on-Ceramic Total Hip Arthroplasty Incidence of Instability and Noise
    Schroder, David
    Bornstein, Lindsey
    Bostrom, Mathias P. G.
    Nestor, Bryan J.
    Padgett, Douglas E.
    Westrich, Geoffrey H.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 437 - 442
  • [39] A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty
    Rosneck, James
    Klika, Alison
    Barsoum, Wael
    JOURNAL OF ARTHROPLASTY, 2008, 23 (02): : 311 - 313
  • [40] A study for a retrieved implant of ceramic-on-ceramic total hip arthroplasty
    Shishido, T
    Yamamoto, K
    Tanaka, S
    Masaoka, T
    Clarke, IC
    Williams, P