Midterm outcome of fourth-generation ceramic-on-ceramic bearing surface in revision total hip arthroplasty

被引:6
|
作者
Chang, Jun-Dong [1 ]
Kim, In-Sung [1 ]
Mansukhani, Sameer Ajit [1 ]
Sharma, Vishwas [1 ]
Lee, Sang-Soo [2 ]
Yoo, Je-Hyun [3 ]
机构
[1] Hallym Univ, Dept Orthopaed Surg, Dongtan Sacred Heart Hosp, 7,Keunjaebong Gil, Hwaseong Si 445907, Gyeonggi Do, South Korea
[2] Hallym Univ, Coll Med, Chuncheon Sacred Heart Hosp, Dept Orthopaed Surg, Chunchon, South Korea
[3] Hallym Univ, Coll Med, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang, Gyeonggi Do, South Korea
关键词
bearing surface; ceramic-on-ceramic; fourth generation; revision; total hip arthroplasty; PERIPROSTHETIC JOINT INFECTION; POLYETHYLENE BEARINGS; MILLION CYCLES; SQUEAKING; COMPLICATIONS; EPIDEMIOLOGY; DISLOCATION; FRACTURES; MECHANISM; LINER;
D O I
10.1177/2309499018783913
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study is to evaluate the clinical and radiologic outcomes after revision total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) bearing surfaces. Methods: A total of 52 revision THAs (28 men and 19 women) using the fourth-gene ration CoC bearing surfaces were retrospectively evaluated. Both acetabular cup and femoral stem were revised in all cases. The mean follow-up period was 7.3 years (range, 4.0-9.9 years). The clinical results with Harris hip score (HHS), Western Ontario McMaster Osteoarthritis Index (WOMAC), and radiologic outcomes were evaluated. Results: At the final follow-up examination, the average HHS was 90.4 (range, 67-100). The average WOMAC pain and physical function score were 2.8 (range, 0-12) and 16.4 (range, 0-42), respectively. Complications were observed in 10 hips (19.2%). However, there were no bearing surface-related complications, and no cases of dislocation and squeaking. Retroacetabular pelvic osteolysis without cup loosening was observed in one hip at the final follow-up. However, no hip showed radiographic signs of cup loosening, vertical or horizontal acetabular cup migrations, and changes of inclinations during the follow-up period. Conclusion: Our data showed that clinical and radiologic outcomes after revision THA using fourth-generation CoC bearing were favorable. Hence, revision THA with the use of CoC bearing surfaces can be preferentially considered. Further studies with long-term follow-up data are warranted.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Midterm Results of Fourth-Generation Ceramic-On-Ceramic Total Hip Arthroplasty
    Cho, Kyu-Jin
    Park, Kyung-Soon
    Jong, Won-Young
    Park, Chun-Gon
    Yoon, Taek-Rim
    INDIAN JOURNAL OF ORTHOPAEDICS, 2019, 53 (05) : 630 - 636
  • [2] Midterm Results of Fourth-Generation Ceramic-On-Ceramic Total Hip Arthroplasty
    Kyu-Jin Cho
    Kyung-Soon Park
    Won-Young Jang
    Chun-Gon Park
    Taek-Rim Yoon
    Indian Journal of Orthopaedics, 2019, 53 : 630 - 636
  • [3] Third-Generation Ceramic-on-Ceramic Bearing Surfaces in Revision Total Hip Arthroplasty
    Chang, Jun-Dong
    Kamdar, Rutuj
    Yoo, Je-Hyun
    Hur, Mina
    Lee, Sang-Soo
    JOURNAL OF ARTHROPLASTY, 2009, 24 (08): : 1231 - 1235
  • [4] Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture
    Marmor, Simon
    Yaacoub, Jean-Jacques
    Aubert, Thomas
    Graff, Wilfrid
    Mouton, Antoine
    Le Strat, Vincent
    Lhotellier, Luc
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (05) : 1197 - 1202
  • [5] Revision total hip arthroplasty by a ceramic bearing surface after a third- and fourth-generation ceramic head or liner fracture
    Simon Marmor
    Jean-Jacques Yaacoub
    Thomas Aubert
    Wilfrid Graff
    Antoine Mouton
    Vincent Le Strat
    Luc Lhotellier
    International Orthopaedics, 2023, 47 : 1197 - 1202
  • [6] Midterm Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty
    Hamilton, William G.
    McAuley, James P.
    Blumenfeld, Thomas J.
    Lesko, James P.
    Himden, Sam E.
    Dennis, Douglas A.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 110 - 115
  • [7] Results of revision of total hip arthroplasty for alumina ceramic-on-ceramic bearing fracture
    Trebse, Rihard
    Mihelic, Anze
    Levasic, Vesna
    Cor, Andrej
    Milosev, Ingrid
    HIP INTERNATIONAL, 2016, 26 (03) : 237 - 243
  • [8] Revision of Ceramic Head Fracture After Third Generation Ceramic-on-Ceramic Total Hip Arthroplasty
    Koo, Kyung-Hoi
    Ha, Yong-Chan
    Kim, Shin-Yoon
    Yoon, Kang-Sup
    Min, Byung-Woo
    Kim, Sang-Rim
    JOURNAL OF ARTHROPLASTY, 2014, 29 (01): : 214 - 218
  • [9] Squeaking in Third- and Fourth-Generation Ceramic-on-Ceramic Total Hip Arthroplasty Meta-Analysis and Systematic Review
    Stanat, Scott J. C.
    Capozzi, James D.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (03): : 445 - 453
  • [10] Incidence, Risk Factors, and Outcome of Ceramic-On-Ceramic Bearing Breakage in Total Hip Arthroplasty
    Hoskins, Wayne
    Rainbird, Sophia
    Peng, Yi
    Lorimer, Michelle
    Graves, Stephen E.
    Bingham, Roger
    JOURNAL OF ARTHROPLASTY, 2021, 36 (08): : 2992 - 2997