Histologic analysis of a fractured implant: A case report

被引:0
|
作者
Brunel, G
Armand, S
Miller, N
Rue, J
机构
[1] Univ Toulouse 3, Fac Odontol, Dept Oral Biol, F-31062 Toulouse, France
[2] Univ Toulouse 3, Fac Odontol, Dept Prosthodont, F-31062 Toulouse, France
[3] Univ Nancy, Fac Odontol, Dept Periodontol, Nancy, France
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study presents the histologic analysis of an implant retrieved 14 months after loading because of a fracture in the collar region. The implant (Biovent) was removed with part of the periimplant tissues, and the block was prepared using cutting and grinding equipment to obtain 3 sections approximately 30 mum thick. The examination evidenced a high degree of osseointegration, with a bone-to-implant contact of 74% +/- 13%. The lamellar bone was dense and in close relation with the hydroxyapatite coating of the implant. The connection between the 0.4-mm hydroxyapatite coating and the metal was always very tight. The thickness of the metal at the break point was assessed to be 1.6 mm. Besides the relative weakness of the metal at the neck of the implant, other possible causes of failure are discussed.
引用
收藏
页码:521 / 526
页数:6
相关论文
共 50 条
  • [31] Scanning electron microscopy and histologic analysis of an apexification "cap" - A case report
    Baldassari-Cruz, LA
    Walton, RE
    Johnson, WT
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (04): : 465 - 468
  • [32] Management of Fractured Zirconia Complete Arch Fixed Implant-Supported Prosthesis Caused by Misfit Due to Diverse Implant Components: A Case Report
    Shuen, Collin
    Bidra, Avinash S.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (06): : 465 - 472
  • [33] Histologic analysis of a retinal prosthesis implant in an animal model
    Ikuno, Y
    Choi, JS
    Nakauchi, K
    Sakaguchi, H
    Kamei, M
    Hirakata, A
    Yagi, T
    Nishimura, S
    Fujikado, T
    Tano, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U701 - U701
  • [34] Amyotonia - Report of a case with histologic observations
    Tuthill, CR
    Levy, MG
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1931, 41 (03): : 591 - 602
  • [35] Alternative approach to salvaging an implant with a fractured screw fragment: A clinical report
    Yi, Yuseung
    Heo, Seong-Joo
    Koak, Jai-Young
    Kim, Seong-Kyun
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (01): : 18 - 21
  • [36] Peri-Implant Mucosal Fenestration and Histologic Observation of Bone Xenograft Material 7-Years After Implant Installation: A Case Report
    Ajlan, Sumaiah A.
    AlHamdan, Khalid S.
    AlQahtani, Dalal A.
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (01) : 18 - 23
  • [37] Late Dental Implant Failures Associated with Retained Root Fragments: Case Reports with Histologic and SEM Analysis
    Nevins, Marc L.
    Langer, Laureen
    Schupbach, Peter
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2018, 38 (01) : 9 - 16
  • [38] FRACTURED BUR AS A PROJECTILE - CASE-REPORT
    BLAIR, GS
    MAXWELL, D
    GLANCEY, I
    BRITISH DENTAL JOURNAL, 1979, 146 (07) : 214 - 216
  • [39] FRACTURED ANEURYSM CLIP - CASE-REPORT
    QUEST, DO
    COUNTEE, RW
    JOURNAL OF NEUROSURGERY, 1977, 47 (03) : 466 - 468
  • [40] Multidisciplinary treatment of a fractured root: a case report
    Cuoghi, Osmar Aparecido
    Bosco, Alvaro Francisco
    de Mendonca, Marcos Rogerio
    Tondelli, Pedro Marcelo
    Miranda-Zamalloa, Yesselin Margot
    AUSTRALIAN ORTHODONTIC JOURNAL, 2010, 26 (01) : 90 - 94