A Zr(IV)-based porphyrinic metal-organic framework as a solid-phase sorbent for extraction of sulfonamides prior to their quantitation by LC-MS

被引:24
|
作者
Deng, Ze-Hui [1 ,2 ]
Xu, Gui-Ju [1 ]
Wang, Xiao-Li [1 ]
Wang, Xia [1 ]
Wang, Ming-Lin [2 ]
Lin, Jin-Ming [3 ]
Zhao, Ru-Song [1 ]
机构
[1] Qilu Univ Technol, Shandong Acad Sci, Shandong Anal & Test Ctr, Key Lab Appl Technol Sophisticated Analyt Instrum, Jinan 250014, Shandong, Peoples R China
[2] Shandong Agr Univ, Coll Food Sci & Engn, Tai An 271018, Shandong, Peoples R China
[3] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Nanoparticles; PCN-224; Absorption; Pretreatment; Antibiotics; Food samples; Water samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; ENVIRONMENTAL WATER SAMPLES; VETERINARY DRUG RESIDUES; MULTICLASS METHOD; ANTIBIOTICS; VALIDATION; SEPARATION; HONEY; MILK;
D O I
10.1007/s00604-018-2985-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A porphyrinic metal-organic framework (PCN-224) was fabricated and used as an adsorbent for solid-phase extraction of ultratrace levels of polar sulfonamide antibiotics from food and drinking waters. The PCN-224 was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and powder X-ray diffraction analyses. Parameters affecting the extraction efficiency were optimized. The sulfonamides were quantified by liquid chromatography-tandem mass spectrometry. Figures of merit include (a) low limits of detection (0.07-0.47 ng center dot L-1), (b) wide linear ranges (0.5-2000 ng center dot L-1), and (c) good repeatabilities (2.8%-6.7%) and reproducibilities (1.7%-5.1%). The method was successfully applied to the determination of sulfonamides in food and drinking water samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Solid-phase extraction with metal-organic frameworks for the analysis of chiral compounds
    Tang, Bo
    Zhang, Jun-Hui
    Zi, Min
    Chen, Xue-Xian
    Yuan, Li-Ming
    CHIRALITY, 2016, 28 (12) : 778 - 783
  • [42] Quantitation of 1α,25-dihydroxyvitamin D by LC-MS/MS using solid-phase extraction and fixed-charge derivitization in comparison to immunoextraction
    Chan, Nancy
    Kaleta, Erin J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (09) : 1399 - 1407
  • [43] A novel metal-organic framework composite MIL-101(Cr)@GO as an efficient sorbent in dispersive micro-solid phase extraction coupling with UHPLC-MS/MS for the determination of sulfonamides in milk samples
    Jia, Xiuna
    Zhao, Pan
    Ye, Xiu
    Zhang, Lianjun
    Wang, Ting
    Chen, Qinyu
    Hou, Xiaohong
    TALANTA, 2017, 169 : 227 - 238
  • [44] Determination of diuretics in human urine using HPLC coupled with magnetic solid-phase extraction based on a metal-organic framework
    Liu, Meng
    Lv, Bingqiang
    Jiang, Hailong
    Yuan, Pei
    Zhu, Huan
    Gao, Binghong
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)
  • [45] Magnetic Solid-Phase Extraction Pretreatment Method for Quantitative Analysis of 12 Steroids in Human Serum Based on LC-MS/MS
    Li, Yanjie
    Wang, Tianyi
    Qin, Suzi
    Li, Yan
    Hu, Wei
    Cheng, Wenbo
    CHROMATOGRAPHIA, 2023, 86 (04) : 333 - 347
  • [46] Preparation of a fluorinated metal-organic framework and its application for the dispersive solid-phase extraction of perfluorooctanoic acid
    Ma, Shi-Yao
    Wang, Jun
    Fan, Li
    Duan, Hui-Ling
    Zhang, Zhi-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1611
  • [47] Pyrolytic in situ magnetization of metal-organic framework MIL-100 for magnetic solid-phase extraction
    Huo, Shu-Hui
    An, Hai-Yan
    Yu, Jing
    Mao, Xue-Feng
    Zhang, Zhe
    Bai, Lei
    Huang, Yan-Feng
    Zhou, Peng-Xin
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1517 : 18 - 25
  • [48] SENSITIVE DETECTION OF α-CONOTOXIN GI IN HUMAN PLASMA USING A SOLID-PHASE EXTRACTION COLUMN AND LC-MS/MS
    Yu, Shuo
    Yang, Bo
    Yan, Liangping
    Dai, Qiuyun
    TOXICON, 2019, 158 : S55 - S56
  • [49] HPLC determination of lincomycin in premixes and feedstuffs with solid-phase extraction on HLB OASIS and LC-MS/MS confirmation
    Dousa, M
    Sikac, Z
    Halama, M
    Lemr, K
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (04) : 981 - 986
  • [50] Sensitive Detection of α-Conotoxin GI in Human Plasma Using a Solid-Phase Extraction Column and LC-MS/MS
    Yu, Shuo
    Yang, Bo
    Yan, Liangping
    Dai, Qiuyun
    TOXINS, 2017, 9 (08):