Analysis of graphene and sulfide coated surface plasmon resonance biosensors

被引:0
|
作者
de Jesus, Priscila Oliveira [1 ]
Rodriguez-Esquerre, Vitaly Felix [1 ]
机构
[1] Univ Fed Bahia, Dept Elect Engn, BR-40155250 Salvador, BA, Brazil
关键词
surface plasmon resonance; optical sensor; biosensor; bimetallic structure; sulfide; graphene; sensitivity; DESIGN;
D O I
10.1117/12.2530113
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work the sensitivity of graphene and sulfide coated biosensors is analyzed in details by an efficient frequency domain finite element method. The proposed sensors are designed by introducing a thin film sulfide coating over a bimetallic surface plasmon resonance biosensor composed by gold and silver. The sensitivity of the proposed sensors can be highly enhanced by introducing the top thin layers. The influence of several sulfide composites in combination with the graphene layer is tuned and optimized by adjusting their optical and geometrical parameters.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] SURFACE PLASMON RESONANCE BIOSENSORS: PRESENT AND FUTURE
    Homola, Jiri
    [J]. X PRACOVNI SETKANI FYZIKALNICH CHEMIKU A ELECTROCHEMIKU/ 10TH WORKSHOP OF PHYSICAL CHEMISTS AND ELECTROCHEMISTS, 2010, : 13 - 14
  • [32] SURFACE PLASMON RESONANCE BIOSENSORS WITH PLASMONIC NANOSTRUCTURES
    Yu, L. -Y.
    Lin, C. -Y.
    Hsu, J. -C.
    Chen, S. -J.
    [J]. PLASMONICS IN BIOLOGY AND MEDICINE VI, 2009, 7192
  • [33] Graphene-MoS2 hybrid nanostructures enhanced surface plasmon resonance biosensors
    Zeng, Shuwen
    Hu, Siyi
    Xia, Jing
    Anderson, Tommy
    Dinh, Xuan-Quyen
    Meng, Xiang-Min
    Coquet, Philippe
    Yong, Ken-Tye
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 801 - 810
  • [34] Research advances on surface plasmon resonance biosensors
    Wang, Qi
    Ren, Zi-Han
    Zhao, Wan-Ming
    Wang, Lei
    Yan, Xin
    Zhu, Ai-song
    Qiu, Feng-mei
    Zhang, Ke-Ke
    [J]. NANOSCALE, 2022, 14 (03) : 564 - 591
  • [35] Sensitivity comparison of surface plasmon resonance and plasmon-waveguide resonance biosensors
    Abbas, Abdennour
    Linman, Matthew J.
    Cheng, Quan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (01) : 169 - 175
  • [36] Proteomic applications of surface plasmon resonance biosensors: analysis of protein arrays
    Yuk, JS
    Ha, KS
    [J]. EXPERIMENTAL AND MOLECULAR MEDICINE, 2005, 37 (01): : 1 - 10
  • [37] Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
    Morton, TA
    Myszka, DG
    [J]. ENERGETICS OF BIOLOGICAL MACROMOLECULES, PT B, 1998, 295 : 268 - +
  • [38] Proteomic applications of surface plasmon resonance biosensors: Analysis of protein arrays
    Yuk J.S.
    Ha K.-S.
    [J]. Experimental & Molecular Medicine, 2005, 37 (1) : 1 - 10
  • [39] Kinetic analysis of macromolecular interactions using surface plasmon resonance biosensors
    Myszka, DG
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 1997, 8 (01) : 50 - 57
  • [40] Analysis of the performance of interferometry, surface plasmon resonance and luminescence as biosensors and chemosensors
    Ince, R.
    Narayanaswamy, R.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 569 (1-2) : 1 - 20