Evaluation of a Handheld Gluten Detection Device

被引:0
|
作者
Taylor, Steve L. [1 ]
Nordlee, Julie A. [1 ]
Jayasena, Shyamali [1 ]
Baumert, Joseph L. [1 ]
机构
[1] Univ Nebraska, Food Innovat Ctr, Food Allergy Res & Resource Program, 1901 North 21st St, Lincoln, NE 68588 USA
关键词
Celiac disease; Consumer; Detection; Gluten; Nima; Sensor; CELIAC-DISEASE; DOUBLE-BLIND; WHEAT; DERMATITIS; DIAGNOSIS; THRESHOLD; CHILDREN; FOODS;
D O I
10.4315/0362-028X.JFP-18-184
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A portable, handheld gluten detection device, the Nima sensor, is now available for consumers wishing to determine if gluten is present in food. By U.S. regulation, gluten-free foods should contain <20 ppm of gluten. Thirteen gluten-free foods (muffins, three different types of bread, three different types of pasta, puffed corn snack, ice cream, meatballs, vinegar and oil salad dressing, oatmeal, and dark chocolate) were prepared; each food was spiked on a weight to weight basis with gluten levels of 0, 5, 10, 20, 30, 40, and 100 ppm before processing or preparation. Unprocessed and processed foods were tested with the handheld gluten sensor and by two gluten-specific enzyme-linked immunosorbent assays (ELISAs) on the basis of the R5 and G12 monoclonal antibodies, respectively. The portable gluten detection device detected gluten in all food types at the 30-ppm addition level, failing to detect gluten in only 5 (6.4%) of 78 subsamples. At the 20-ppm addition level, the portable gluten detection device failed to detect gluten in one type of pasta but detected gluten residues in 63 (87.5%) of 72 other subsamples. The device was able to detect gluten at the 10-ppm addition level in 9 of the 13 food matrices (41 of 54 subsamples, 75.9%) but not in the three types of pasta and the puffed corn snack. The gluten-sensing device did not perform reliably at the 5-ppm addition level in 11 of 13 food matrices (exceptions: ice cream and muffins). In contrast, the ELISA methods were highly reliable at gluten addition levels of >= 10 ppm in all food matrices. The portable gluten detection device yielded a low percentage of false-positive results (4 of 111, 3.6%) in these food matrices. Thus, this handheld portable gluten sensor performed reliably in the detection of gluten in foods having >= 20 ppm of added gluten with only 18 (5.9%) of 306 failures, if results of the one type of pasta are excluded. The device worked with greater reliability as the gluten levels in the foods increased.
引用
收藏
页码:1723 / 1728
页数:6
相关论文
共 50 条
  • [1] A handheld English pronunciation evaluation device
    You, K
    Kim, H
    Chang, H
    Lee, J
    Sung, W
    ICCE: 2005 INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, DIGEST OF TECHNICAL PAPERS, 2005, : 267 - 268
  • [2] Handheld device for counterfeit drug detection to be tested in Africa
    McCarthy, Michael
    BMJ-BRITISH MEDICAL JOURNAL, 2013, 346
  • [3] Design and Evaluation of a Handheld Robotic Device for Peripheral Catheterization
    Leipheimer, Josh
    Batter, Max
    Chen, Alvin
    Yarmush, Martin
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2022, 16 (02):
  • [4] A Handheld Adaptive Optics Device for Personalized Visual Evaluation
    Soomro, Shoaib R.
    Artal, Pablo
    OPHTHALMIC TECHNOLOGIES XXXIII, 2023, 12360
  • [5] Vesp'R: design and evaluation of a handheld AR device
    Veas, Eduardo
    Kruijff, Ernst
    7TH IEEE INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY 2008, PROCEEDINGS, 2008, : 43 - +
  • [6] A Drill Signal Detection Technology for Handheld Medical Drilling Device
    Mayer, Michael
    Lin, Hsin-Hung
    Peng, Ying-Hua
    Lee, Pei Yuan
    Wang, Min-Liang
    2014 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C 2014), 2014, : 958 - 961
  • [7] Automatic Detection of Atrial Fibrillation Based on Handheld ECG Device
    Tseng, Chun-Wei
    Lin, Geng-Hong
    Chang, Chung-Hung
    Chan, Hau-Yu
    Tsai, Cheng-Lun
    Lin, Yue-Der
    Lin, Kang-Ping
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 506 - +
  • [8] A Portable Handheld Microfluidic Colorimetric Device for the Detection of Organophosphorus Pesticides
    Deepak, K. S.
    Dubey, Satish Kumar
    Goel, Sanket
    Javed, Arshad
    IEEE SENSORS JOURNAL, 2025, 25 (02) : 3465 - 3472
  • [9] Handheld Device Review of Abdominal CT for the Evaluation of Acute Appendicitis
    Choudhri, Asim F.
    Carr, Thomas M., III
    Ho, Christopher P.
    Stone, James R.
    Gay, Spencer B.
    Lambert, Drew L.
    JOURNAL OF DIGITAL IMAGING, 2012, 25 (04) : 492 - 496
  • [10] Handheld Device Review of Abdominal CT for the Evaluation of Acute Appendicitis
    Asim F. Choudhri
    Thomas M. Carr
    Christopher P. Ho
    James R. Stone
    Spencer B. Gay
    Drew L. Lambert
    Journal of Digital Imaging, 2012, 25 : 492 - 496