Feasibility of Magnetic Resonance Elastography for the Pancreas at 3T

被引:41
|
作者
Itoh, Yohei [1 ]
Takehara, Yasuo [2 ]
Kawase, Toshihiro [3 ]
Terashima, Kenichi [4 ]
Ohkawa, Yoshihisa [5 ]
Hirose, Yuko [1 ]
Koda, Ai [1 ]
Hyodo, Naoko [1 ]
Ushio, Takasuke [1 ]
Hirai, Yuki [1 ]
Yoshizawa, Nobuko [1 ]
Yamashita, Shuhei [1 ]
Nasu, Hatsuko [1 ]
Ohishi, Naoki [2 ]
Sakahara, Harumi [1 ]
机构
[1] Hamamatsu Univ, Sch Med, Dept Diagnost Radiol & Nucl Med, Hamamatsu, Shizuoka, Japan
[2] Hamamatsu Univ Hosp, Dept Radiol, Hamamatsu, Shizuoka 4313192, Japan
[3] Chutoen Gen Med Ctr, Dept Radiol Technol, Kakegawa, Japan
[4] GE Healthcare, Tokyo, Japan
[5] Chutoen Gen Med Ctr, Dept Diagnost Radiol, Kakegawa, Japan
关键词
MR ELASTOGRAPHY; FIBROSIS; STIFFNESS; DIAGNOSIS; CANCER;
D O I
10.1002/jmri.24995
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: 1) To assess the usefulness of an elastic belt bracing the upper abdomen for reducing the miscalculated areas of the pancreas on 3.0T magnetic resonance elastography (MRE); 2) to test whether MRE can detect difference of stiffness between normal pancreas and the focal pancreatic diseases. Materials and Methods: Using an initial eight normal volunteers, miscalculated areas were compared between MRE with the elastic belt and without the belt on 3.0T MRI. Then, using the belt, MRE of the normal pancreas was measured using 14 volunteers and 11 patients with focal pancreatic lesions. Results: The median (95% confidence interval [CI]) percentages of correctly calculated areas were 57.4% (32.9-63.0) with the elastic belt and 35.3% (11.4-60.4) without the belt (P=0.0078). The stiffness of each pancreatic segment of the normal volunteers (mean+/-SE) was 2.37+/-0.16 kPa for the head, 2.46+/-0.17 kPa for the body, and 2.58+/-0.26 kPa for the tail. The stiffness of seven pancreatic cancers was 6.06+/-0.49 kPa, which was higher than the overall pancreatic stiffness of the normal volunteers (2.47+/-0.11 kPa, P < 0.0001). Stiffness of the pancreatic lesions in the head of 6.03+/-0.42 kPa, body of 5.57+/-0.82 kPa, and tail of 5.9+/-1.9 kPa were also higher than those of corresponding segments of the normal volunteers (P=0.0011, 0.0029, and 0.029, respectively). Conclusion: With the elastic belt, miscalculation of the pancreatic stiffness was reduced. MRE showed differences of stiffness between normal pancreas and pancreatic lesions.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 50 条
  • [21] 3T magnetic resonance arteriography in pediatric cerebrovascular disease
    Zimmerman, R. A.
    Bilaniuk, L. T.
    JOURNAL OF NEURORADIOLOGY, 2007, 34 (02) : 95 - 100
  • [22] Feasibility and reproducibility of relaxometry, morphometric. and geometrical measurements of the hip joint with magnetic resonance imaging at 3T
    Carballido-Gamio, Julio
    Link, Thomas M.
    Li, Xiaojuan
    Han, Eric T.
    Krug, Roland
    Ries, Michael D.
    Majumdar, Sharmila
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) : 227 - 235
  • [23] In Vivo Renal Lipid Quantification by Accelerated Magnetic Resonance Spectroscopic Imaging at 3T: Feasibility and Reliability Study
    Alhulail, Ahmad A.
    Servati, Mahsa
    Ooms, Nathan
    Akin, Oguz
    Dincer, Alp
    Thomas, M. Albert
    Dydak, Ulrike
    Emir, Uzay E.
    METABOLITES, 2022, 12 (05)
  • [24] Feasibility of magnetic resonance elastography in the healthy rat heart
    Smith, Lisa
    Skulberg, Vidar Magne
    Zhang, Lili
    Sjaastad, Ivar
    Espe, Emil Knut Stenersen
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [25] Magnetic resonance elastography of uterine leiomyomas: a feasibility study
    Stewart, Elizabeth A.
    Taran, F. Andrei
    Chen, Jun
    Gostout, Bobbie S.
    Woodrum, David A.
    Felmlee, Joel P.
    Ehman, Richard L.
    FERTILITY AND STERILITY, 2011, 95 (01) : 281 - 284
  • [26] Magnetic resonance elastography of the pancreas: Measurement reproducibility and relationship with age
    Kolipaka, Arunark
    Schroeder, Samuel
    Mo, Xiaokui
    Shah, Zarine
    Hart, Phil A.
    Conwell, Darwin L.
    MAGNETIC RESONANCE IMAGING, 2017, 42 : 1 - 7
  • [27] High resolution 3T magnetic resonance neurography of the peroneal nerve
    Pineda, D.
    Barroso, F.
    Chaves, H.
    Cejas, C.
    RADIOLOGIA, 2014, 56 (02): : 107 - 117
  • [28] 3T Magnetic resonance imaging and computed tomography of the bovine carpus
    Usama Hagag
    Ayman El Nahas
    Zakriya Ali Almohamad
    Walter Brehm
    Kerstin Gerlach
    BMC Veterinary Research, 18
  • [29] Meralgia paresthetica: Now showing on 3T magnetic resonance neurography
    Ally, Raihaan M.
    Velleman, Mark D.
    Suleman, Farhana E.
    SA JOURNAL OF RADIOLOGY, 2019, 23 (01):
  • [30] Proton magnetic resonance spectroscopy of human cervical spondylosis at 3T
    N Salamon
    B M Ellingson
    R Nagarajan
    N Gebara
    A Thomas
    L T Holly
    Spinal Cord, 2013, 51 : 558 - 563