Stimuli-Responsive Reagent System for Enabling Microfluidic Immunoassays with Biomarker Purification and Enrichment

被引:29
|
作者
Hoffman, John M. [1 ]
Stayton, Patrick S. [1 ]
Hoffman, Allan S. [1 ]
Lai, James J. [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
PROSTATE-SPECIFIC ANTIGEN; PROTEIN ADSORPTION; PLASMA PROTEOME; MASS-TRANSPORT; WHOLE-BLOOD; BINDING; CANCER; ASSAY; POLYMERS; PLATFORM;
D O I
10.1021/bc500522k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Immunoassays have been translated into microfluidic device formats, but significant challenges relating to upstream sample processing still limit their applications. Here, stimuli-responsive polymer-antibody conjugates are utilized in a microfluidic immunoassay to enable rapid biomarker purification and enrichment as well as sensitive detection. The conjugates were constructed by covalently grafting poly(N-isopropylacrylamide) (PNIPAAm), a thermally responsive polymer, to the lysine residues of anti-prostate specific antigen (PSA) Immunoglobulin G (IgG) using carbodiimide chemistry via the polymer end-carboxylate. The antibody-PNIPAAm (capture) conjugates and antibody-alkaline phosphatase (detection) conjugates formed sandwich immunocomplexes via PSA binding in 50% human plasma. The complexes were loaded into a recirculating poly(dimethylsiloxane) microreactor, equipped with micropumps and transverse flow features, for subsequent separation, enrichment, and quantification. The immunocomplexes were captured by heating the solution to 39 degrees C, mixed over the transverse features for 2 min, and washed with warm buffer. In one approach, the assay utilized immunocomplex solution that was contained in an 80 nL microreactor, which was loaded with solution at room temperature and subsequently heated to 39 degrees C. The assay took 25 min and resulted in 37 pM PSA limit of detection (LOD), which is comparable to a plate ELISA employing the same antibody pair. In another approach, the microreactor was preheated to 39 degrees C, and immunocomplex solution was flowed through the reactor, mixed, and washed. When the specimen volume was increased to 7.5 mu L by repeating the capture process three times, the higher specimen volume led to immunocomplex enrichment within the microreactor. The resulting assay LOD was 0.5 pM, which is 2 orders of magnitude lower than the plate ELISA. Both approaches generate antigen specific signal over a clinically significant range. The sample processing capabilities and subsequent utility in a biomarker assay demonstrate the opportunity for stimuli-responsive polymer-protein conjugates in novel diagnostic technologies.
引用
收藏
页码:29 / 38
页数:10
相关论文
共 50 条
  • [41] Stimuli-Responsive DNA Nanostructure Drug Delivery System Based on Tumor Microenvironment
    Wu, Qing
    Tang, Yiyuan
    Yu, Miao
    Zhang, Yueying
    Li, Xingmei
    PROGRESS IN CHEMISTRY, 2020, 32 (07) : 927 - 934
  • [42] Carbon-Nanotube-Based Stimuli-Responsive Controlled-Release System
    Chen, Xuecheng
    Chen, Hongmin
    Tripisciano, Carla
    Jedrzejewska, Anna
    Ruemmeli, Mark H.
    Klingeler, Ruediger
    Kalenczuk, Ryszard J.
    Chu, Paul K.
    Borowiak-Palen, Ewa
    CHEMISTRY-A EUROPEAN JOURNAL, 2011, 17 (16) : 4454 - 4459
  • [43] Advanced application of stimuli-responsive drug delivery system for inflammatory arthritis treatment
    Department of Biomedical Materials Science, College of Biomedical Engineering, Third Military Medical University, Chongqing
    400038, China
    不详
    400037, China
    不详
    400054, China
    不详
    400038, China
    Mater. Today Bio., 2022,
  • [44] Advanced application of stimuli-responsive drug delivery system for inflammatory arthritis treatment
    Zhang, Mi
    Hu, Wenhui
    Cai, Chenhui
    Wu, Yu
    Li, Jianmei
    Dong, Shiwu
    MATERIALS TODAY BIO, 2022, 14
  • [45] Purification and enrichment of virus samples utilizing magnetic beads on a microfluidic system
    Lien, Kang-Yi
    Lin, Jr-Lung
    Liu, Cheng-Yu
    Lei, Huan-Yao
    Lee, Gwo-Bin
    LAB ON A CHIP, 2007, 7 (07) : 868 - 875
  • [46] Dual Stimuli-Responsive Pickering Emulsions from Novel Magnetic Hydroxyapatite Nanoparticles and Their Characterization Using a Microfluidic Platform
    Mendiratta, Shruti
    Ali, Ahmed Atef Ahmed
    Hejazi, Seyed Hossein
    Gates, Ian
    LANGMUIR, 2021, 37 (04) : 1353 - 1364
  • [47] CdS QDs-chitosan microcapsules with stimuli-responsive property generated by gas-liquid microfluidic technique
    Chen, Yanjun
    Yao, Rongyi
    Wang, Yifeng
    Chen, Ming
    Qiu, Tong
    Zhang, Chaocan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2015, 125 : 21 - 27
  • [48] Emerging Strategies in Stimuli-Responsive Nanocarriers as the Drug Delivery System for Enhanced Cancer Therapy
    Saravanakumar, Kandasamy
    Hu, Xiaowen
    Ali, Davoodbasha M.
    Wang, Myeong-Hyeon
    CURRENT PHARMACEUTICAL DESIGN, 2019, 25 (24) : 2609 - 2625
  • [49] Microgel-based surface modifying system for stimuli-responsive functional finishing of cotton
    Kulkarni, Amit
    Tourrette, Audrey
    Warmoeskerken, Marijn M. C. G.
    Jocic, Dragan
    CARBOHYDRATE POLYMERS, 2010, 82 (04) : 1306 - 1314
  • [50] Tailoring stimuli-responsive delivery system driven by metal-ligand coordination bonding
    Liang, Hongshan
    Zhou, Bin
    He, Yun
    Pei, Yaqiong
    Li, Bin
    Li, Jing
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 3315 - +