A hybrid approach to mid-shaft clavicle fixation

被引:10
|
作者
Rawlings, Mathew [1 ]
Knox, David [2 ,3 ]
Patel, Minoo [2 ,3 ,4 ]
Ackland, David [1 ]
机构
[1] Univ Melbourne, Dept Mech Engn, Parkville, Vic 3010, Australia
[2] Epworth Healthcare, Dept Orthopaed Surg, Richmond, Vic 3121, Australia
[3] Epworth Ctr, Ctr Limb Reconstruct, Richmond, Vic 3121, Australia
[4] Monash Univ, Dept Surg, Southern Clin Sch, Clayton, Vic 3168, Australia
关键词
Clavicle fracture; Biomechanics; Surgery; Locking screw; Vascular injury; PLATE FIXATION; BIOMECHANICAL EVALUATION; OPERATIVE TREATMENT; SCREW PLACEMENT; OPEN REDUCTION; FRACTURES; OSTEOSYNTHESIS; EPIDEMIOLOGY; STABILITY; STRENGTH;
D O I
10.1016/j.injury.2016.01.042
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The purpose of this study was to demonstrate the strength characteristics of a hybrid uni-cortical construct for clavicle fixation. The technique reported aims to combine benefits of uni-cortical fixation with stability comparable to traditional bi-cortical fixation. The approach utilises long, oblique uni-cortical screws at the distal ends of the plate acting as surrogate bi-cortical screws. Locked uni-cortical screws positioned centrally provide bending and torsion strength to the construct. This alternative hybrid uni-cortical technique does not require far cortex screw or drill penetration required in bi-cortical fixation techniques, thus avoiding potentially catastrophic vascular and or neurologic injury. The purpose of this study was to compare the mechanical behaviour of the hybrid uni-cortical construct to standard bi-cortical fixations under both torsion and bending loads. Method: Thirty osteotomized human cadaveric clavicles were randomly allocated to three surgical fixation techniques: bi-cortical locked screw fixation, bi-cortical non-locked screw fixation and hybrid uni-cortical screw fixation. Each clavicle construct was tested non-destructively under torsional loading, and then under cantilever bending to failure. Construct bending and torsional stiffness, as well as ultimate failure strength, were measured. Results: There were no significant differences between uni-cortical or bi-cortical fixation constructs in either bending stiffness or ultimate bending moment (p > 0.05); however, there was a trend towards greater bending stiffness in the hybrid construct. The uni-cortical hybrid fixation technique displayed a significantly lower mean torsional stiffness value when compared with the bi-cortical locked screw fixation (mean difference: 134.4 Nmm/degrees, 95% confidence interval [ 32.3, 236.4], p = 0.007). Conclusion: A hybrid uni-cortical approach to clavicle plate fixation that may improve screw purchase and reduce risk of intra-operative vascular damage demonstrates comparable bending strength to current bi-cortical approaches. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:893 / 898
页数:6
相关论文
共 50 条
  • [11] Meta-analysis of plate fixation versus intramedullary fixation for the treatment of mid-shaft clavicle fractures
    Bing Zhang
    Yanbin Zhu
    Fei Zhang
    Wei Chen
    Ye Tian
    Yingze Zhang
    [J]. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 23
  • [12] Revisiting the surgical indication of mid-shaft clavicle fractures: Clavicle asymmetry
    Ergisi, Yilmaz
    Ozdemir, Erdi
    Tikman, Mesut
    Korkmazer, Selcuk
    Kekec, Halil
    Yalcin, Nadir
    [J]. JOINT DISEASES AND RELATED SURGERY, 2023, 34 (01): : 63 - 68
  • [13] Medical management of displaced mid-shaft clavicle fractures
    Sheps, David
    [J]. BRITISH COLUMBIA MEDICAL JOURNAL, 2016, 58 (01): : 36 - 37
  • [14] Plate osteosynthesis for mid-shaft clavicle fractures: An update
    Annicchiarico, Nicola
    Latta, Arturo
    Santolini, Emmanuele
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S53 - S57
  • [15] Treatment of mid-shaft clavicle fractures: A comparative study
    Thyagarajan, David S.
    Day, Marion
    Dent, Colin
    Williams, Rhys
    Evans, Richard
    [J]. INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2009, 3 (02): : 23 - 27
  • [16] Effects of Internal Fixation for Mid-Shaft Clavicle Fractures on Shoulder Kinematics During Humeral Elevations
    Hung, Li-Wei
    Lu, Hsuan-Yu
    Chang, Chung-Hsun
    Chen, Tsan-Yang
    Wang, Ting-Ming
    Lu, Tung-Wu
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [17] Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures
    Chen, Xiaobin
    Shannon, Steven F.
    Torchia, Michael
    Schoch, Bradley
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (06) : 749 - 754
  • [18] Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures
    Xiaobin Chen
    Steven F. Shannon
    Michael Torchia
    Bradley Schoch
    [J]. Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 749 - 754
  • [19] Displaced Mid-Shaft Clavicle Fractures: A Subset For Surgical Treatment
    Choudhari, P.
    Chhabra
    [J]. MALAYSIAN ORTHOPAEDIC JOURNAL, 2014, 8 (02) : 1 - 5
  • [20] OUTCOMES OF MANAGEMENT OF MID-SHAFT CLAVICLE FRACTURES IN SAUDI ARABIA
    Alqahtani, Mohammed Saeed
    Alsalaiman, Zyad Musaad
    Almejrad, Fahad Abdulmohsen
    Alqarni, Moayad Abdullah
    Al Sirhani, Meshari Ushabab
    [J]. INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (01): : 1122 - 1130