A hybrid approach to mid-shaft clavicle fixation

被引:10
|
作者
Rawlings, Mathew [1 ]
Knox, David [2 ,3 ]
Patel, Minoo [2 ,3 ,4 ]
Ackland, David [1 ]
机构
[1] Univ Melbourne, Dept Mech Engn, Parkville, Vic 3010, Australia
[2] Epworth Healthcare, Dept Orthopaed Surg, Richmond, Vic 3121, Australia
[3] Epworth Ctr, Ctr Limb Reconstruct, Richmond, Vic 3121, Australia
[4] Monash Univ, Dept Surg, Southern Clin Sch, Clayton, Vic 3168, Australia
关键词
Clavicle fracture; Biomechanics; Surgery; Locking screw; Vascular injury; PLATE FIXATION; BIOMECHANICAL EVALUATION; OPERATIVE TREATMENT; SCREW PLACEMENT; OPEN REDUCTION; FRACTURES; OSTEOSYNTHESIS; EPIDEMIOLOGY; STABILITY; STRENGTH;
D O I
10.1016/j.injury.2016.01.042
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The purpose of this study was to demonstrate the strength characteristics of a hybrid uni-cortical construct for clavicle fixation. The technique reported aims to combine benefits of uni-cortical fixation with stability comparable to traditional bi-cortical fixation. The approach utilises long, oblique uni-cortical screws at the distal ends of the plate acting as surrogate bi-cortical screws. Locked uni-cortical screws positioned centrally provide bending and torsion strength to the construct. This alternative hybrid uni-cortical technique does not require far cortex screw or drill penetration required in bi-cortical fixation techniques, thus avoiding potentially catastrophic vascular and or neurologic injury. The purpose of this study was to compare the mechanical behaviour of the hybrid uni-cortical construct to standard bi-cortical fixations under both torsion and bending loads. Method: Thirty osteotomized human cadaveric clavicles were randomly allocated to three surgical fixation techniques: bi-cortical locked screw fixation, bi-cortical non-locked screw fixation and hybrid uni-cortical screw fixation. Each clavicle construct was tested non-destructively under torsional loading, and then under cantilever bending to failure. Construct bending and torsional stiffness, as well as ultimate failure strength, were measured. Results: There were no significant differences between uni-cortical or bi-cortical fixation constructs in either bending stiffness or ultimate bending moment (p > 0.05); however, there was a trend towards greater bending stiffness in the hybrid construct. The uni-cortical hybrid fixation technique displayed a significantly lower mean torsional stiffness value when compared with the bi-cortical locked screw fixation (mean difference: 134.4 Nmm/degrees, 95% confidence interval [ 32.3, 236.4], p = 0.007). Conclusion: A hybrid uni-cortical approach to clavicle plate fixation that may improve screw purchase and reduce risk of intra-operative vascular damage demonstrates comparable bending strength to current bi-cortical approaches. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:893 / 898
页数:6
相关论文
共 50 条
  • [1] The Treatment of Mid-shaft Clavicle Fractures
    Sang Qing-Hua
    Gou Zhi-Gang
    Zheng Hua-Yong
    Yuan Jing-Tao
    Zhao Jian-Wen
    He Hong-Ying
    Liu Chuang
    Liu Zhi
    [J]. 中华医学杂志(英文版), 2015, (21) : 2946 - 2951
  • [2] The Treatment of Mid-shaft Clavicle Fractures
    Sang, Qing-Hua
    Gou, Zhi-Gang
    Zheng, Hua-Yong
    Yuan, Jing-Tao
    Zhao, Jian-Wen
    He, Hong-Ying
    Liu, Chuang
    Liu, Zhi
    [J]. CHINESE MEDICAL JOURNAL, 2015, 128 (21) : 2946 - 2951
  • [3] Surgical Treatment of Mid-Shaft Clavicle Fractures: Plate Fixation and Clinical Outcomes
    Ozan, Firat
    Dogar, Fatih
    Altay, Taskin
    Mujde, Salih
    Koyuncu, Semmi
    Vatansever, Fatih
    Bulut, Tugrul
    [J]. JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 : 792 - 796
  • [4] Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review
    Houwert, R. Marijn
    Wijdicks, Frans-Jasper
    Bisschop, Charlotte Steins
    Verleisdonk, Egbert-Jan
    Kruyt, Moyo
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) : 579 - 585
  • [5] Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review
    R. Marijn Houwert
    Frans-Jasper Wijdicks
    Charlotte Steins Bisschop
    Egbert-Jan Verleisdonk
    Moyo Kruyt
    [J]. International Orthopaedics, 2012, 36 : 579 - 585
  • [6] Biomechanical performance of an intramedullary Echidna pin for fixation of comminuted mid-shaft clavicle fractures
    Sidhu, Navjit
    Huntington, Lachlan S.
    Richardson, Martin
    Ackland, David C.
    [J]. ANZ JOURNAL OF SURGERY, 2019, 89 (10) : 1308 - 1313
  • [7] Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures
    Ashman, Bradley D.
    Slobogean, Gerard P.
    Stone, Trevor B.
    Viskontas, Darius G.
    Moola, Farhad O.
    Perey, Bertrand H.
    Boyer, Dory S.
    McCormack, Robert G.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (10): : 1549 - 1553
  • [8] Extraperiosteal Dual Plate Fixation of Acute Mid-Shaft Clavicle Fractures: A Technical Trick
    Shannon, Steven F.
    Chen, Xiaobin
    Torchia, Michael
    Schoch, Bradley
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (10) : E346 - E350
  • [9] A Comparative Study Between Plate Fixation and Intramedullary Fixation for Displaced Mid-Shaft Clavicle Fractures in Adults
    Vajrangi, A.
    Shetty, S., V
    Shenoy, R. M.
    [J]. MALAYSIAN ORTHOPAEDIC JOURNAL, 2022, 16 (01) : 40 - 45
  • [10] Meta-analysis of plate fixation versus intramedullary fixation for the treatment of mid-shaft clavicle fractures
    Bing Zhang
    Yanbin Zhu
    Fei Zhang
    Wei Chen
    Ye Tian
    Yingze Zhang
    [J]. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 23