Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function

被引:11
|
作者
Linder, Jonathan R. [3 ,7 ]
Stauss, Harald M. [5 ]
Gindes, Holly [3 ]
Pierce, Gary L. [5 ]
Von Bergen, Nicholas H. [2 ]
Haynes, William G. [1 ,4 ]
Fiedorowicz, Jess G. [1 ,3 ,6 ]
机构
[1] Univ Iowa, Dept Internal Med, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Pediat, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Psychiat, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
[4] Univ Iowa, Inst Clin & Translat Sci, Iowa City, IA 52242 USA
[5] Univ Iowa, Coll Liberal Arts Sci, Dept Hlth & Human Physiol, Iowa City, IA 52242 USA
[6] Univ Iowa, Coll Publ Hlth, Dept Epidemiol, Iowa City, IA 52242 USA
[7] Univ Iowa, Coll Pharm, Iowa City, IA 52242 USA
来源
基金
美国国家卫生研究院;
关键词
EndoPAT; Finometer Pro; Cardiovascular function; Device validation; SPECTRAL-ANALYSIS; SENSITIVITY; VALIDATION; FINOMETER;
D O I
10.1186/1471-2261-14-180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to determine whether heart rate variability (HRV), blood pressure (BP) variability, and baroreceptor-heart rate reflex sensitivity can be reliably assessed using finger volume pulse waveforms obtained from the commercially available EndoPAT device. Methods: Non-invasive BP (Finometer Pro as a non-invasive standard) and finger volume (EndoPAT) waveforms were recorded in 65 adults (37 +/- 14 years; 60% female) and systolic BP and heart rate (HR) time series were derived after calibrating the EndoPAT signal based on systolic and diastolic BP values obtained by a sphygomomanometer. Transfer function analyses were performed to test for coherence between systolic BP and HR time series derived from the Finometer and EndoPAT devices. Time-domain HRV parameters, frequency domain HR and systolic BP variability parameters, and baroreflex sensitivity (sequence technique) were computed from Finometer- and EndoPAT-derived time series and intraclass correlation coefficients (ICC) were calculated. Results: Squared coherence between systolic BP time series derived from the Finometer and EndoPAT devices was low, suggesting poor correlation. In contrast, squared coherence between HR time series derived from the two devices was excellent [High Frequency (HF) = 0.80, Low Frequency (LF) = 0.81], with gain values close to 1.0. ICC values for time- and frequency-domain HRV parameters were excellent (>0.9 except for relative HF HRV, which was 0.77), while ICC values for frequency-domain BP variability parameters and baroreceptor-HR reflex sensitivity were low. Conclusions: Finger volume pulse waveforms can be used to reliably assess both time-domain and frequency-domain HR variability. However, frequency domain BP variability parameters cannot be reliably assessed from finger volume pulse waveforms using the simple calibration technique used in this study.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Blood pressure and heart rate variability and baroreflex sensitivity before and after brain death
    Conci, F
    Di Rienzo, M
    Castiglioni, P
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2001, 71 (05): : 621 - 631
  • [22] Differential effects of the blood pressure state on pulse rate variability and heart rate variability in critically ill patients
    Mejia-Mejia, Elisa
    May, James M.
    Elgendi, Mohamed
    Kyriacou, Panayiotis A.
    NPJ DIGITAL MEDICINE, 2021, 4 (01)
  • [23] Automated analysis of finger blood pressure recordings provides insight in determinants of baroreflex sensitivity and heart rate variability—the HELIUS study
    D. Collard
    B. E. Westerhof
    J. M. Karemaker
    W. J. Stok
    P. G. Postema
    C. T. P. Krediet
    L. Vogt
    B. J. H. van den Born
    Medical & Biological Engineering & Computing, 2023, 61 : 1183 - 1191
  • [24] Differential effects of the blood pressure state on pulse rate variability and heart rate variability in critically ill patients
    Elisa Mejía-Mejía
    James M. May
    Mohamed Elgendi
    Panayiotis A. Kyriacou
    npj Digital Medicine, 4
  • [25] Pulse rate variability corresponds with heart rate variability in the evaluation of autonomic function
    Bulte, C. S. E.
    Keet, S. W. M.
    Loer, S. A.
    Boer, C.
    Bouwman, R. A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 46 - 46
  • [26] Effect of the data sampling rate on accuracy of indices for heart rate and blood pressure variability and baroreflex function in resting rats and mice
    Bhatia, Vivek
    Rarick, Kevin R.
    Stauss, Harald M.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) : 1185 - 1201
  • [27] Deriving heart period variability from blood pressure waveforms
    McKinley, PS
    Shapiro, PA
    Bagiella, E
    Myers, MM
    De Meersman, RE
    Grant, I
    Sloan, RP
    JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (04) : 1431 - 1438
  • [28] Relationship of blood pressure variability and heart rate variability with prostatic volume in patients with benign prostatic hyperplasia
    金江丽
    China Medical Abstracts (Internal Medicine), 2014, 31 (03) : 157 - 157
  • [29] The effects of slow breathing rate on heart rate variability and blood pressure variability
    Chang, Qinghua
    Liu, Renguang
    Shen, Zhongyuan
    CARDIOLOGY, 2013, 126 : 163 - 163
  • [30] EFFECTS OF HEART RATE ON BLOOD PRESSURE AND BLOOD PRESSURE VARIABILITY
    Koorathota, Sharath C.
    Sloan, Richard P.
    Schwartz, Joseph
    PSYCHOSOMATIC MEDICINE, 2019, 81 (04): : A43 - A43