Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function

被引:11
|
作者
Linder, Jonathan R. [3 ,7 ]
Stauss, Harald M. [5 ]
Gindes, Holly [3 ]
Pierce, Gary L. [5 ]
Von Bergen, Nicholas H. [2 ]
Haynes, William G. [1 ,4 ]
Fiedorowicz, Jess G. [1 ,3 ,6 ]
机构
[1] Univ Iowa, Dept Internal Med, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Pediat, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Psychiat, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
[4] Univ Iowa, Inst Clin & Translat Sci, Iowa City, IA 52242 USA
[5] Univ Iowa, Coll Liberal Arts Sci, Dept Hlth & Human Physiol, Iowa City, IA 52242 USA
[6] Univ Iowa, Coll Publ Hlth, Dept Epidemiol, Iowa City, IA 52242 USA
[7] Univ Iowa, Coll Pharm, Iowa City, IA 52242 USA
来源
基金
美国国家卫生研究院;
关键词
EndoPAT; Finometer Pro; Cardiovascular function; Device validation; SPECTRAL-ANALYSIS; SENSITIVITY; VALIDATION; FINOMETER;
D O I
10.1186/1471-2261-14-180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We sought to determine whether heart rate variability (HRV), blood pressure (BP) variability, and baroreceptor-heart rate reflex sensitivity can be reliably assessed using finger volume pulse waveforms obtained from the commercially available EndoPAT device. Methods: Non-invasive BP (Finometer Pro as a non-invasive standard) and finger volume (EndoPAT) waveforms were recorded in 65 adults (37 +/- 14 years; 60% female) and systolic BP and heart rate (HR) time series were derived after calibrating the EndoPAT signal based on systolic and diastolic BP values obtained by a sphygomomanometer. Transfer function analyses were performed to test for coherence between systolic BP and HR time series derived from the Finometer and EndoPAT devices. Time-domain HRV parameters, frequency domain HR and systolic BP variability parameters, and baroreflex sensitivity (sequence technique) were computed from Finometer- and EndoPAT-derived time series and intraclass correlation coefficients (ICC) were calculated. Results: Squared coherence between systolic BP time series derived from the Finometer and EndoPAT devices was low, suggesting poor correlation. In contrast, squared coherence between HR time series derived from the two devices was excellent [High Frequency (HF) = 0.80, Low Frequency (LF) = 0.81], with gain values close to 1.0. ICC values for time- and frequency-domain HRV parameters were excellent (>0.9 except for relative HF HRV, which was 0.77), while ICC values for frequency-domain BP variability parameters and baroreceptor-HR reflex sensitivity were low. Conclusions: Finger volume pulse waveforms can be used to reliably assess both time-domain and frequency-domain HR variability. However, frequency domain BP variability parameters cannot be reliably assessed from finger volume pulse waveforms using the simple calibration technique used in this study.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Finger volume pulse waveforms facilitate reliable assessment of heart rate variability, but not blood pressure variability or baroreflex function
    Jonathan R Linder
    Harald M Stauss
    Holly Gindes
    Gary L Pierce
    Nicholas H Von Bergen
    William G Haynes
    Jess G Fiedorowicz
    [J]. BMC Cardiovascular Disorders, 14
  • [2] Heart rate variability, blood pressure variability, and baroreflex sensitivity in overtrained athletes
    Baumert, Mathias
    Brechtel, Lars
    Lock, Juergen
    Hermsdorf, Mario
    Wolff, Roland
    Barer, Vico
    Voss, Andreas
    [J]. CLINICAL JOURNAL OF SPORT MEDICINE, 2006, 16 (05): : 412 - 417
  • [3] Age dependency of heart rate variability, blood pressure variability and baroreflex sensitivity
    Wang, Shouyan
    Zhang, Lifan
    Wang, Xingbang
    Cheng, Jiuhua
    [J]. Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 2000, 13 (05): : 318 - 322
  • [4] Stroke Outcome Prediction by Blood Pressure Variability, Heart Rate Variability, and Baroreflex Sensitivity
    Tang, Shujin
    Xiong, Li
    Fan, Yuhua
    Mok, Vincent C. T.
    Wong, Ka Sing
    Leung, Thomas W.
    [J]. STROKE, 2020, 51 (04) : 1317 - 1320
  • [5] Changes in blood pressure variability, heart rate variability and baroreflex sensitivity associated with pheochromocytoma
    Finta, E
    Laude, D
    Alföldi, S
    Kun, E
    Járai, Z
    Kiss, I
    Farsang, C
    Elghozi, JL
    [J]. JOURNAL OF HYPERTENSION, 2005, 23 : S154 - S154
  • [6] Baroreflex sensitivity, heart rate, and blood pressure variability in normal pregnancy
    Voss, A
    Malberg, H
    Schumann, A
    Wessel, N
    Walther, T
    Stepan, H
    Faber, R
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2000, 13 (11) : 1218 - 1225
  • [7] Computer analysis of blood pressure and heart rate variability: The baroreflex testing
    Parati, G.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2004, 11 : 346 - 347
  • [8] A baroreflex model of short term blood pressure and heart rate variability
    Ten Voorde, Ben J.
    Kingma, René
    [J]. Studies in Health Technology and Informatics, 2000, 71 : 179 - 200
  • [9] Sequential analysis of heart rate variability, blood pressure variability and baroreflex sensitivity in healthy pregnancy
    Priyanka Garg
    Kavita Yadav
    Ashok Kumar Jaryal
    Garima Kachhawa
    Alka Kriplani
    Kishore Kumar Deepak
    [J]. Clinical Autonomic Research, 2020, 30 : 433 - 439
  • [10] Sequential analysis of heart rate variability, blood pressure variability and baroreflex sensitivity in healthy pregnancy
    Garg, Priyanka
    Yadav, Kavita
    Jaryal, Ashok Kumar
    Kachhawa, Garima
    Kriplani, Alka
    Deepak, Kishore Kumar
    [J]. CLINICAL AUTONOMIC RESEARCH, 2020, 30 (05) : 433 - 439