Robotic mitral valve repair: Experience with the da Vinci system

被引:139
|
作者
Nifong, LW
Chu, VF
Bailey, BM
Maziarz, DM
Sorrell, VL
Holbert, D
Chitwood, WR
机构
[1] E Carolina Univ, Dept Surg, Brody Sch Med, Greenville, NC 27858 USA
[2] E Carolina Univ, Ctr Minimally Invas & Robot Surg, Brody Sch Med, Greenville, NC 27858 USA
[3] E Carolina Univ, Med Ctr, Brody Sch Med, Greenville, NC 27858 USA
[4] E Carolina Univ, Ctr Stat, Brody Sch Med, Greenville, NC 27858 USA
来源
ANNALS OF THORACIC SURGERY | 2003年 / 75卷 / 02期
关键词
D O I
10.1016/S0003-4975(02)04554-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. As part of a Food and Drug Administration trial, mitral repairs were performed in 38 patients using the robotic da Vinci surgical system (Intuitive Surgical, Inc, Mountain View, CA). Prospectively, we evaluated safety and efficacy in performing both simple and complex mitral repairs. Methods. Eligible patients had nonischemic moderate to severe mitral insufficiency. Operative techniques included peripheral cardiopulmonary perfusion, a 4- to 5-cm mini-thoracotomy, transthoracic aortic occlusion, and antegrade blood cardioplegia. Transesophageal echocardiograrns were done intraoperatively with three-dimensional reconstructions. Successful repairs were defined as mild or less residual regurgitation. Results. Enhanced three-dimensional visualization of mitral leaflets and the subvalvar apparatus allowed safe, dexterous intracardiac tissue manipulation. All patients had successful valve repairs including quadrangular resections, sliding plasties, and edge-to-edge approximations, as well as both chordal transfers and replacements. There were no operative deaths, strokes, or device- related complications. One patient required valve replacement for hemolysis and 1 was reexplored for bleeding. There were no incisional conversions. Both robotic repair and total operating times decreased significantly from 1.9 +/- 0.1 and 5.1 +/- 0.1 hours (mean standard error of the mean) for the first 19 patients to 1.5 +/- 0.1 (p = 0.002) and 4.4 +/- 0.1 hours (p = 0.04) for the last 19 operations, respectively. Total hospital length of stay for patients was 3.8 +/- 0.6 days. Of all patients, 31 (82%) had a 4-day or less length of stay. Seven patients (18%) had stays between 5 and 9 days (6.4 +/- 1.0). Conclusions. This study shows that the da Vinci surgical system (Intuitive Surgical, Inc) has few limitations in performing complex valve repairs. Articulated wrist-like instruments and three-dimensional visualization enabled precise tissue telernanipulation. Future robotic design advances and adjunctive suture technologies may promote continuing evolution of robotic cardiac operations. (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [1] Robotic mitral valve repair: Experience with the da Vinci system - Discussion
    Smith, CR
    Nifong
    ANNALS OF THORACIC SURGERY, 2003, 75 (02): : 443 - 443
  • [2] Robotic assisted mitral valve repair: early experience with the da Vinci S robotic system
    Mega, S.
    Bono, M. C.
    Castiglione, I.
    Ranocchi, F.
    Casacalenda, A.
    Contento, C.
    Menichetti, A.
    Patti, G.
    Di Sciascio, G.
    Musumeci, F.
    EUROPEAN HEART JOURNAL, 2013, 34 : 979 - 979
  • [3] Minimally invasive mitral valve repair using the da Vinci robotic system
    Tatooles, AJ
    Pappas, PS
    Gordon, PJ
    Slaughter, MS
    ANNALS OF THORACIC SURGERY, 2004, 77 (06): : 1978 - 1984
  • [4] Computer-enhanced telemanipulation in mitral valve repair: preliminary experience in Canada with the da Vinci robotic system
    McClure, R. Scott
    Kiaii, Bob
    Novick, Richard J.
    Rayman, Reiza
    Swinamer, Stuart
    Kodera, Kojiro
    Menkis, Alan H.
    CANADIAN JOURNAL OF SURGERY, 2006, 49 (03) : 193 - 196
  • [5] Robotic mitral valve repair: Trapezoidal resection and prosthetic annuloplasty with the da Vinci surgical system
    Chitwood, WR
    Nifong, LW
    Elbeery, JE
    Chapman, WH
    Albrecht, R
    Kim, V
    Young, JA
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (06): : 1171 - 1172
  • [6] Complex Bileaflet Mitral Valve Repair (Barlow's) Using the da Vinci Robotic Surgical System
    Masroor, Saqib
    Nifong, L. Wiley
    Chitwood, W. Randolph, Jr.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2006, 1 (05) : 276 - 278
  • [7] ROBOTIC EXPERIENCE WITH MITRAL VALVE REPAIR
    Trento, A.
    Ramzy, D.
    De Robertis, M.
    Mirocha, J.
    Cheng, W.
    Czer, L.
    CARDIOLOGY, 2015, 132 : 34 - 34
  • [8] Complex Repair of a Barlow's Valve Using the Da Vinci Robotic Surgical System
    Masroor, Saqib
    Plambeck, Christopher
    Dahnert, Melissa
    JOURNAL OF HEART VALVE DISEASE, 2010, 19 (05): : 593 - 595
  • [9] Three-dimensional transoesophageal echocardiographic imaging for support of minimally invasive robotic mitral valve repair using the da Vinci system - first experience in Poland
    Kurnicka, Katarzyna
    Wrobel, Krzysztof
    Zielinski, Dariusz
    Juraszynski, Zbigniew
    Biederman, Andrzej
    Pruszczyk, Piotr
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2019, 15 (03): : 382 - 384
  • [10] Robotic mitral valve repair-the Bruxelles experience
    Aphram, Gaby
    Melina, Giovanni
    Noirhomme, Philippe
    De Kerchove, Laurent
    Mastrobuoni, Stefano
    Klepper, Maureen
    El Khoury, Gebrine
    Navarra, Emiliano
    ANNALS OF CARDIOTHORACIC SURGERY, 2022, 11 (06) : 589 - 595