Glaucoma Drainage Device Erosion Following Ptosis Surgery

被引:1
|
作者
Bae, Steven S. [1 ]
Campbell, Robert J. [2 ,3 ,4 ,5 ]
机构
[1] Queens Univ, Sch Med, Kingston, ON, Canada
[2] Queens Univ, Dept Ophthalmol, Kingston, ON, Canada
[3] Hop Hotel Dieu, Dept Ophthalmol, 166 Brock St, Kingston, ON K7L 5G2, Canada
[4] Kingston Gen Hosp, Kingston, ON, Canada
[5] Inst Clin Evaluat Sci, Kingston, ON, Canada
关键词
glaucoma; glaucoma drainage device; glaucoma drainage implant; erosion; ptosis surgery; RISK-FACTORS; EXPOSURE; IMPLANT; TUBE; OUTCOMES;
D O I
10.1097/IJG.0000000000000679
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To highlight the potential risk of glaucoma drainage device erosion following ptosis surgery. Methods: Case report. Results: A 71-year-old man underwent uncomplicated superotemporal Ahmed glaucoma valve implantation in the left eye in 2008. Approximately 8 years later, the patient underwent bilateral ptosis repair, which successfully raised the upper eyelid position. Three months postoperatively, the patient's glaucoma drainage implant tube eroded through the corneal graft tissue and overlying conjunctiva to become exposed. A graft revision surgery was successfully performed with no further complications. Conclusions: Caution and conservative lid elevation may be warranted when performing ptosis repair in patients with a glaucoma drainage implant, and patients with a glaucoma implant undergoing ptosis surgery should be followed closely for signs of tube erosion.
引用
收藏
页码:E200 / E201
页数:2
相关论文
共 50 条
  • [21] Surgical drainage of choroidal effusions following glaucoma surgery
    WuDunn, D
    Ryser, D
    Cantor, LB
    JOURNAL OF GLAUCOMA, 2005, 14 (02) : 103 - 108
  • [22] Intraocular Sensor for Pressure Monitoring Following Glaucoma Drainage Device
    Saxby, Edward
    Tatham, Andrew J.
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (03): : 304 - 304
  • [23] Fibrin glue-assisted glaucoma drainage device surgery
    Kahook, M. Y.
    Noecker, R. J.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) : 1486 - 1489
  • [24] Long-term results of glaucoma drainage device surgery
    Konstantine Purtskhvanidze
    Mark Saeger
    Felix Treumer
    Johann Roider
    Bernhard Nölle
    BMC Ophthalmology, 19
  • [25] Trabeculectomy can be Successful after Glaucoma Drainage Device surgery
    Alizadeh, Reza
    Akil, Handan
    Tan, James C.
    Law, Simon K.
    Caprioli, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [26] A Comparison of Sequential Glaucoma Drainage Device Implantation Versus Cyclophotocoagulation Following Failure of a Primary Drainage Device
    Levinson, Joshua D.
    Giangiacomo, Annette L.
    Beck, Allen D.
    Pruett, Paul B.
    Superak, Hillary M.
    Lynn, Michael J.
    Costarides, Anastasios P.
    JOURNAL OF GLAUCOMA, 2017, 26 (04) : 311 - 314
  • [27] A Comparison of Sequential Glaucoma Drainage Device Implantation versus Cyclophotocoagulation Following Failure of a Primary Drainage Device
    Levinson, Joshua
    Giangiacomo, Annette
    Beck, Allen
    Pruett, Paul
    Costarides, Anastasios
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [28] Control and optimisation of fluid flow in glaucoma drainage device surgery
    Kin Sheng Lim
    Eye, 2018, 32 : 230 - 234
  • [29] Long-term results of glaucoma drainage device surgery
    Purtskhvanidze, Konstantine
    Saeger, Mark
    Treumer, Felix
    Roider, Johann
    Noelle, Bernhard
    BMC OPHTHALMOLOGY, 2019, 19 (1)
  • [30] Control and optimisation of fluid flow in glaucoma drainage device surgery
    Lim, Kin Sheng
    EYE, 2018, 32 (02) : 230 - 234