In vivo measurement of human body composition by dual-energy X-ray absorptiometry (DXA)

被引:0
|
作者
Thomsen, TK [1 ]
Jensen, VJ [1 ]
Henriksen, MG [1 ]
机构
[1] Kolding Hosp, Dept Surg, Kolding, Denmark
关键词
fat; lean tissue mass; radiation; nutrition; reproducibility; precision;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To evaluate measurements of human body composition using dual energy X-ray absorptiometry and to assess its precision and variations within and between observers as well as the influence of food and fluid intake. Design: Experimental study. Setting: District hospital, Denmark. Subjects: 17 volunteers, 12 male and 5 female. Interventions: Repeated scans under standard conditions. Main outcome measures: Precision, variations within and between observers, and influence of the degree of hydration. Results: The repeatability coefficients and the coefficients of variation (CV) were obtained for the four body compartments: tissue mass 416 g (CV 0.2%); fat mass 1117 g (CV 2.6%); lean tissue mass 1425 g (CV 0.9%), and total bone mineral content, (BMC) 109 g (CV 1.2%). There was no significant intraobserver variation. There was little interobserver variation in assessing tissue mass and BMC, but there were significant differences when judging fat and lean tissue mass. Drinking resulted in significantly increased values for tissue and lean tissue mass, which corresponded to the intake. Conclusion: DXA is precise and reproducible with little variation within and between observers. It might be useful in clinical studies.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 50 条
  • [41] Methodology Review: Using Dual-Energy X-Ray Absorptiometry (DXA) for the Assessment of Body Composition in Athletes and Active People
    Nana, Alisa
    Slater, Gary J.
    Stewart, Arthur D.
    Burke, Louise M.
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2015, 25 (02) : 198 - 215
  • [42] Comparison of two phantoms for body composition with dual-energy X-ray absorptiometry
    Diessel, E
    Shepherd, JA
    Fuerst, T
    Gonzalez, M
    Genant, HK
    Carew, B
    Looker, A
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 107 - 110
  • [43] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158
  • [44] Pediatric body composition by dual energy X-ray absorptiometry (DXA): Precision of total body measures
    Horlick, M
    Thornton, J
    Margulies, L
    Wang, J
    Ioannidou, E
    Heymsfield, S
    OBESITY RESEARCH, 2004, 12 : A214 - A214
  • [45] Body composition assessment by dual-energy X-ray absorptiometry (DXA) [Valutazione della composizione corporea mediante la densitometria a raggi X (DXA)]
    Andreoli A.
    Scalzo G.
    Masala S.
    Tarantino U.
    Guglielmi G.
    La radiologia medica, 2009, 114 (2) : 286 - 300
  • [46] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96
  • [47] Dual-energy X-ray Absorptiometry
    Jain, Rajesh K.
    Vokes, Tamara
    JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) : 291 - 303
  • [48] Assessing body composition and changes in body composition - Another look at dual-energy X-ray absorptiometry
    Lohman, TG
    Harris, M
    Teixeira, PJ
    Weiss, L
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 45 - 54
  • [49] Osteosarcopenia-The Role of Dual-Energy X-ray Absorptiometry (DXA) in Diagnostics
    Gonera-Furman, Aleksandra
    Bolanowski, Marek
    Jedrzejuk, Diana
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [50] Comparison of patient screening techniques for dual-energy X-ray absorptiometry (DXA)
    Cook, RB
    Collins, D
    Zioupos, P
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S35 - S35