Bite Force Transducers and Measurement Devices

被引:35
|
作者
Gu, Yingzhi [1 ]
Bai, Yuxing [1 ]
Xie, Xianju [1 ]
机构
[1] Capital Med Univ, Beijing Stomatol Hosp, Dept Orthodont, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
bite force; force transducer; masticatory system; bite force device; force measurement; OVERDENTURE; CHILDREN; MUSCLE; SENSOR; SIGNS; LIP;
D O I
10.3389/fbioe.2021.665081
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In dental research, bite force has become an important curative effect evaluation index for tooth restoration, periodontal treatment, and orthodontic treatment. Bite force is an important parameter to evaluate the efficacy of the masticatory system. Physicians obtain the therapeutic basis for occlusal adjustment by measuring the bite force and the dynamic changes in occlusal contact at different stages of treatment and objectively evaluate the therapeutic effect. At present, many devices are used to record the bite force. Most of these devices use force transducers to detect bite force, such as strain gauge transducers, piezoresistive transducers, piezoelectric transducers, optical fiber transducers, and pressure-sensitive films. This article summarizes the various equipment used to record bite force, related materials and the characteristics of this equipment. It provides a reference for physicians to make choices during the clinical process and at the same time provides a basis for the development of new occlusal force measurement materials.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Measurement of masseter muscle size and bite force.
    Shiau, YY
    Peng, CC
    Hsu, CW
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 645 - 645
  • [12] A Device For Multi-teeth Bite Force Measurement
    Jian, Chuyao
    Yi, Yunrui
    Deng, Lingyun
    Luo, Jie
    IEEE ICARM 2016 - 2016 INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM), 2016, : 657 - 662
  • [13] Fiber Bragg Grating based bite force measurement
    Umesh, Sharath
    Padma, Srivani
    Asokan, Sundarrajan
    Srinivas, Talabattula
    JOURNAL OF BIOMECHANICS, 2016, 49 (13) : 2877 - 2881
  • [14] Effect of occlusal morphology on the accuracy of bite force measurements using thin film transducers
    Rottner, K
    Richter, EJ
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2004, 17 (05) : 518 - 523
  • [15] Bite force measurement based on fiber Bragg grating sensor
    Padma, Srivani
    Umesh, Sharath
    Asokan, Sundarrajan
    Srinivas, Talabattula
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (10)
  • [16] A Low-Cost Wireless Bite Force Measurement Device
    De Pasquale, Paolo
    Rubino, Erasmo
    Borzelli, Daniele
    Peditto, Matteo
    Siniscalchi, Enrico Nastro
    De Ponte, Francesco Saverio
    Oteri, Giacomo
    d'Avella, Andrea
    MATERIALS, 2022, 15 (11)
  • [17] The correlation between two occlusal analyzers for the measurement of bite force
    Yi-Fang Huang
    Chin-Man Wang
    Wann-Yun Shieh
    Yu-Fang Liao
    Hsiang-Hsi Hong
    Chung-Ta Chang
    BMC Oral Health, 22
  • [18] The correlation between two occlusal analyzers for the measurement of bite force
    Huang, Yi-Fang
    Wang, Chin-Man
    Shieh, Wann-Yun
    Liao, Yu-Fang
    Hong, Hsiang-Hsi
    Chang, Chung-Ta
    BMC ORAL HEALTH, 2022, 22 (01)
  • [19] Influence of different ultrasonic transducers on the precision of fastening force measurement
    Liu, Yongmeng
    Zhi, Junjie
    Liu, Enxiao
    Chen, Yuanlin
    Wang, Xiaoming
    Sun, Chuanzhi
    Zifei, Cao
    Ma, Huiping
    Tan, Jiubin
    APPLIED ACOUSTICS, 2022, 185
  • [20] Time synchronized measurement of multi-bridge force transducers
    Andrae, J
    Sawla, A
    MEASUREMENT, 2001, 29 (02) : 105 - 111