Bismuth-Nanocomposites Modified SPCEs for Non-Enzymatic Electrochemical Sensors

被引:7
|
作者
Madagalam, Mallikarjun [1 ,2 ]
Bartoli, Mattia [1 ,3 ]
Tagliaferro, Alberto [1 ,3 ]
Carrara, Sandro [2 ]
机构
[1] Politecn Torino, Dept Appl Sci & Technol, I-10129 Turin, Italy
[2] EPFL, ICLAB, Bio CMOS Interfaces Grp, CH-2002 Neuchatel, Switzerland
[3] Consorzio Interuniv Nazl Sci & Tecnol Mat INSTM, I-50121 Florence, Italy
关键词
Sensors; Electrodes; Bismuth; Carbon; Biosensors; Sensitivity; Temperature sensors; Bismuth-nanocomposites; electrochemical sensors; kinetic rate constant; limit of detection; nanoparticles; screen printed electrodes; sensitivity;
D O I
10.1109/JSEN.2021.3059278
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present newly developed electrochemical sensors based on screen-printed carbon electrodes functionalized with HO-BiONO3, polyethylene glycol coated HO-BiONO3, and Bi-5 O-7 NO3. The performance of these sensors has been studied by cyclic voltammetry experiments and compared in terms of the kinetic rate constant, the sensitivity, and the limit of detection. The polyethylene glycol coated HO-BiONO3 sensor was found with higher oxidation peak current, lower oxidation peak potential, and assured a faster paracetamol reaction due to a higher kinetic rate constant of 42.0 +/- 9.8 ms(-1). This sensor also possessed lesser peakto-peak separation (Delta E-p) of 243 +/- 10mV with a higher chance of reversible reaction compared to other developed sensors. The polyethylene glycol coated HO-BiONO3 sensor also registered a sensitivity of 43.50 +/- 0.54 mu A/mM with a relative standard deviation of 1.24 %, which is more than double compared to the bare screen-printed electrode with a limit of detection of 2.24 +/- 0.03 mu M (R-2 = 0.998, n = 3). HO-BiONO3 and Bi-5 O-7 NO3 sensors also performed much better with slightly higher kinetic rate constant and higher sensitivity than the bare screen-printed electrode sensor.
引用
收藏
页码:11155 / 11162
页数:8
相关论文
共 50 条
  • [21] High-selectivity electrochemical non-enzymatic sensors based on graphene/Pd nanocomposites functionalized with designated ionic liquids
    Wang, Chueh-Han
    Yang, Cheng-Hsien
    Chang, Jeng-Kuei
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 483 - 488
  • [22] Non-enzymatic electrochemical glucose sensors based on polyaniline/reduced-graphene-oxide nanocomposites functionalized with silver nanoparticles
    Deshmukh, Megha A.
    Kang, Byeong-Cheol
    Ha, Tae-Jun
    JOURNAL OF MATERIALS CHEMISTRY C, 2020, 8 (15) : 5112 - 5123
  • [23] Review-Trends on the Development of Non-Enzymatic Electrochemical Sensors Modified with Molecularly Imprinted Polymers for the Quantification of Glucose
    Hernandez-Ramirez, D.
    Franco-Guzmaan, M.
    Ibarra-Ortega, I. S.
    Alvarez-Romero, G. A.
    Rebolledo-Perales, L. E.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (07)
  • [24] A Review on Non-Enzymatic Electrochemical Biosensors of Glucose Using Carbon Nanofiber Nanocomposites
    Mohammadpour-Haratbar, Ali
    Mohammadpour-Haratbar, Saeid
    Zare, Yasser
    Rhee, Kyong Yop
    Park, Soo-Jin
    BIOSENSORS-BASEL, 2022, 12 (11):
  • [25] Non-Enzymatic Electrochemical Biosensing of Glucose Using Nanocomposites of Polyaniline Nanofibers and Silver
    Varghese, Eldhose V.
    Saidu, Femina Kanjirathamthadathil
    Schwandt, Carsten
    Thomas, George
    Joseph, Alex
    CHEMISTRYSELECT, 2022, 7 (01):
  • [26] A non-enzymatic electrochemical sensor based on polyaniline/borophene nanocomposites for dopamine detection
    Baytemir, Gulsen
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2023, 129 (02):
  • [27] A non-enzymatic electrochemical sensor based on polyaniline/borophene nanocomposites for dopamine detection
    Gülsen Baytemir
    Applied Physics A, 2023, 129
  • [28] Non-enzymatic electrochemical sensing of hydrogen peroxide based on polypyrrole/platinum nanocomposites
    Xing, Liwen
    Rong, Qinfeng
    Ma, Zhanfang
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 242 - 247
  • [29] PtAu/C based bimetallic nanocomposites for non-enzymatic electrochemical glucose detection
    Singh, Baljit
    Laffir, Fathima
    McCormac, Timothy
    Dempsey, Eithne
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 150 (01): : 80 - 92
  • [30] A novel non-enzymatic electrochemical glucose sensor modified with FeOOH nanowire
    Xia, Cao
    Ning, Wang
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (11) : 1581 - 1584