Several optical configurations aiming to create images of sub-millimetre objects with magnification from I to 100 have been experimentally tested at the ESRF BM5 beamline. A Kirkpatrick-Baez (KB) system is used for focusing the beam into a 30 microns spot and then direct projection images are recorded. Some results using a spherical crystal downstream from the KB system are presented. The possibility to focus the synchrotron beam into a 40 microns spot using an spherical crystal in quasi-normal incidence is demonstrated and its use for projection microscopy is discussed.
引用
收藏
页码:267 / 270
页数:4
相关论文
共 50 条
  • [1] X-ray projection imaging
    Seibert, JA
    [J]. IMAGING IN RADIATION THERAPY, 1998, (24): : 103 - 134
  • [2] Projection X-ray Imaging: Radiography, Mammography, Fluoroscopy
    Seibert, James Anthony
    [J]. HEALTH PHYSICS, 2019, 116 (02): : 148 - 156
  • [3] Benchtop Coherent X-Ray Scatter Projection Imaging: From Synchrotrons to X-Ray Tubes
    Dydula, C.
    Johns, P. C.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E383 - E383
  • [4] Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging
    Bernhard Stimpel
    Christopher Syben
    Tobias Würfl
    Katharina Breininger
    Philip Hoelter
    Arnd Dörfler
    Andreas Maier
    [J]. Scientific Reports, 9
  • [5] Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging
    Stimpel, Bernhard
    Syben, Christopher
    Wuerfl, Tobias
    Breininger, Katharina
    Hoelter, Philip
    Doerfler, Arnd
    Maier, Andreas
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [6] Iterative reconstruction of brachytherapy seed configurations from x-ray projection images
    Murphy, M
    Todor, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1809 - 1809
  • [7] Evaluation of Gratings for X-ray and Neutron Phase Imaging Techniques by Using X-ray Projection Microscope
    Minami, Katsunori
    Yashiro, Wataru
    Olbinado, Margie
    Momose, Atsushi
    [J]. INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 193 - 198
  • [8] X-ray projection simulation based on physical imaging model
    Tang, Shaojie
    Yu, Hengyong
    Yan, Hao
    Bharkhada, Deepak
    Mou, Xuanqin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (03) : 177 - 189
  • [9] REDUCING THE EFFECTS OF SCATTERED PHOTONS IN X-RAY PROJECTION IMAGING
    FAHIMI, H
    MACOVSKI, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (01) : 56 - 63
  • [10] X-ray projection simulation based on physical imaging model
    Institute of Image Processing and Pattern Recognition, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
    不详
    [J]. J X Ray Sci Technol, 2006, 3 (177-189):