Genotyping performance evaluation of commercially available HIV-1 drug resistance test

被引:9
|
作者
Rosemary, Audu [1 ]
Chika, Onwuamah [1 ]
Jonathan, Okpokwu
Godwin, Imade [2 ]
Georgina, Odaibo [3 ]
Azuka, Okwuraiwe [1 ]
Zaidat, Musa [1 ]
Philippe, Chebu [4 ]
Oliver, Ezechi [1 ]
Oche, Agbaji [2 ]
David, Olaleye [3 ]
Jay, Samuel [4 ]
Ibrahim, Dalhatu [5 ]
Mukhtar, Ahmed
Joshua, DeVos [6 ]
Yang Chunfu [6 ]
Elliot, Raizes [6 ]
Beth, Chaplin [7 ]
Phyllis, Kanki [7 ]
Emmanuel, Idigbe [1 ]
机构
[1] Nigerian Inst Med Res, Lagos, Nigeria
[2] Jos Univ Teaching Hosp, Jos, Nigeria
[3] Univ Coll Hosp, Ibadan, Nigeria
[4] AIDS Prevent Initiat Nigeria, Abuja, Nigeria
[5] Ctr Dis Control & Prevent, Abuja, Nigeria
[6] Ctr Dis Control & Prevent, Div Global HIV & TB, Ctr Global Hlth, Atlanta, GA USA
[7] Harvard TH Chan Sch Publ Hlth, Dept Immunol & Infect Dis, Boston, MA USA
来源
PLOS ONE | 2018年 / 13卷 / 06期
关键词
IMMUNODEFICIENCY-VIRUS TYPE-1; DRIED BLOOD SPOTS; PLASMA; SUBTYPE; HEALTH; ADULTS;
D O I
10.1371/journal.pone.0198246
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background ATCC HIV-1 drug resistance test kit was designed to detect HIV-1 drug resistance (HIVDR) mutations in the protease and reverse transcriptase genes for all HIV-1 group M subtypes and circulating recombinant forms. The test has been validated for both plasma and dried blood spot specimen types with viral load (VL) of >= 1000 copies/ml. We performed an in-country assessment on the kit to determine the genotyping sensitivity and its accuracy in detecting HIVDR mutations using plasma samples stored under suboptimal conditions. Methods Among 572 samples with VL >= 1000 copies/ml that had been genotyped by ViroSeq assay, 183 were randomly selected, including 85 successful genotyped and 98 unsuccessful genotyped samples. They were tested with ATCC kits following the manufacturer's instructions. Sequence identity and HIVDR patterns were analysed with Stanford University HIV Drug Resistance HIVdb program. Results Of the 183 samples, 127 (69.4%) were successfully genotyped by either method. While ViroSeq system genotyped 85/183 (46.5%) with median VL of 32,971 (IQR: 11,150-96,506) copies/ml, ATCC genotyped 115/183 (62.8%) samples with median VL of 23,068 (IQR: 7,397-86,086) copies/ml. Of the 98 unsuccessful genotyped samples with ViroSeq assay, 42 (42.9%) samples with lower median VL of 13,906 (IQR: 6,122-72,329) copies/ml were successfully genotyped using ATCC. Sequence identity analysis revealed that the sequences generated by both methods were > 98% identical and yielded similar HIVDR profiles at individual patient level. Conclusion This study confirms that ATCC kit showed greater sensitivity in genotyping plasma samples stored in suboptimal conditions experiencing frequent and prolonged power outage. Thus, it is more sensitive particularly for subtypes A and A/G HIV-1 in resource-limited settings.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Evaluation of the ABL NGS assay for HIV-1 drug resistance testing
    Lhossein, Thomas
    Sylvain, Karine
    Morel, Virginie
    Demey, Baptiste
    Brochot, Etienne
    Descamps, Veronique
    [J]. HELIYON, 2023, 9 (11)
  • [42] Evaluation of dried blood spots for HIV-1 drug resistance testing
    García-Lerma, J
    McNulty, A
    Jennings, C
    Bennett, D
    Fitzgibbon, J
    Morack, R
    Ussery, M
    Folks, TM
    Kalish, ML
    Heneine, W
    [J]. ANTIVIRAL THERAPY, 2005, 10 (04) : S49 - S49
  • [43] Evaluation of dried blood spots for HIV-1 drug resistance testing
    García-Lerma, JG
    McNulty, A
    Jennings, C
    Bennett, D
    Fitzgibbon, J
    Morack, R
    Ussery, M
    Folks, TM
    Kalish, ML
    Heneine, W
    [J]. ANTIVIRAL THERAPY, 2005, 10 : S49 - S49
  • [44] Development, Validation and Clinical Evaluation of a Low Cost In-House HIV-1 Drug Resistance Genotyping Assay for Indian Patients
    Acharya, Arpan
    Vaniawala, Salil
    Shah, Parth
    Misra, Rabindra Nath
    Wani, Minal
    Mukhopadhyaya, Pratap N.
    [J]. PLOS ONE, 2014, 9 (08):
  • [45] High Failure Rate of the ViroSeq HIV-1 Genotyping System for Drug Resistance Testing in Cameroon, a Country with Broad HIV-1 Genetic Diversity
    Aghokeng, Avelin F.
    Mpoudi-Ngole, Eitel
    Chia, Julius E.
    Edoul, Elvine M.
    Delaporte, Eric
    Peeters, Martine
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (04) : 1635 - 1641
  • [46] HIV-1 drug resistance testing from dried blood spots collected in rural Tanzania using the ViroSeq HIV-1 Genotyping System
    Johannessen, Asgeir
    Garrido, Carolina
    Zahonero, Natalia
    Naman, Ezra
    de Mendoza, Carmen
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2011, 66 (02) : 260 - 264
  • [47] Performance evaluation of the two protease sequencing primers of the Trugene HIV-1 genotyping kit
    Ribas, Sergio Garcia
    Heyndrickx, Leo
    Ondoa, Pascale
    Fransen, Katrien
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2006, 135 (02) : 137 - 142
  • [48] PERFORMANCE EVALUATION OF COMMERCIALLY AVAILABLE SENSITOMETERS
    GOLDMAN, LW
    WATKINS, RT
    [J]. JOURNAL OF APPLIED PHOTOGRAPHIC ENGINEERING, 1978, 4 (03): : 143 - 147
  • [49] Comparison of nine resistance interpretation systems for HIV-1 genotyping
    Stürmer, M
    Doerr, HW
    Staszewski, S
    Preiser, W
    [J]. ANTIVIRAL THERAPY, 2003, 8 (03) : 239 - 244
  • [50] Evaluation of two commercially available alternatives for HIV-1 viral load testing in resource-limited settings
    Steegen, Kim
    Luchters, Stanley
    De Cabooter, Nancy
    Reynaerts, Jacqueline
    Mandaliya, Kishor
    Plum, Jean
    Jaoko, Walter
    Verhofstede, Chris
    Temmerman, Marleen
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2007, 146 (1-2) : 178 - 187