Impact of Chemical Cleaning on Furnace Exit Gas Temperature of Power Plant:Case Study Steam Power Plant Unit 1

被引:0
|
作者
Silalahi, Netha A. M. [1 ]
Widanarko, Baskoro [2 ]
Jaganathan, Saravana Kumar [3 ]
机构
[1] Indonesia Power Co Ltd, Power Generat Engn, Jakarta, Indonesia
[2] Indonesia Power Co Ltd, Maintenance Serv Unit, Jakarta, Indonesia
[3] Univ Hull, Fac Engn, Kingston Upon Hull, N Humberside, England
关键词
chemical cleaning; superheater; furnace exit gas temperature;
D O I
10.1109/CPEEE51686.2021.9383340
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Superheater as a part of thermal steam power plant could be damaged by deposit. If there is no significant degradation of material, in concern of reliability of power plant, the deposit could be removed by chemical cleaning. Alkali chemical cleaning is chosen since the material is sensitive to low pH and the chemical composition of deposit analysis. Process parameter is monitored continuously. After chemical treatment, there is even distribution of temperature on superheater tubes describes the better heat distribution at superheater tubes (Delta T = 10 - 25 degrees C) and also Furnace Exit Gas Temperature (Delta T = 50 degrees C) reduced significantly indicating the better heat transfer in boiler. Improvement of heat transfer of boiler as the result of proper chemical cleaning maybe beneficial in improving the boiler efficiency
引用
收藏
页码:182 / 188
页数:7
相关论文
共 50 条
  • [21] A New Approach for Temperature Control in Steam Power Plant
    Chaibakhsh, A.
    Ghaffari, A.
    Rezaeifar, A.
    2008 MEDITERRANEAN CONFERENCE ON CONTROL AUTOMATION, VOLS 1-4, 2008, : 159 - +
  • [22] GAS TURBINE-STEAM TURBINE POWER PLANT FOR PRODUCTION OF ELECTRICITY AND PROCESS STEAM FOR A CHEMICAL INDUSTRY
    SAUVENIE.J
    VIDOSSIC.G
    MECHANICAL ENGINEERING, 1970, 92 (07) : 56 - &
  • [23] Energy, exergy and exergoeconomic analysis of a steam power plant: A case study
    Ameri, Mohammad
    Ahmadi, Pouria
    Hamidi, Armita
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (05) : 499 - 512
  • [24] Steam temperature stability in a direct steam generation solar power plant
    Birnbaum, Juergen
    Feldhoff, Jan Fabian
    Fichtner, Markus
    Hirsch, Tobias
    Jocker, Markus
    Pitz-Paal, Robert
    Zimmermann, Gerhard
    SOLAR ENERGY, 2011, 85 (04) : 660 - 668
  • [25] ANALYSIS OF MAIN PROPERTIES OF A STEAM POWER UNIT WITH A PEAK LOAD GAS-TURBINE PLANT
    KIRILLOV, II
    ARSENEV, LV
    KORSOV, YG
    POLISHCHUK, VL
    KHODAK, EA
    THERMAL ENGINEERING, 1976, 23 (05) : 30 - 32
  • [26] Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia
    Nugraha, Ariyana Dwiputra
    Harianto
    Muflikhun, Muhammad Akhsin
    RESULTS IN ENGINEERING, 2023, 17
  • [27] BP plant to get gas fired power unit
    不详
    OIL & GAS JOURNAL, 1996, 94 (35) : 23 - 23
  • [28] UNITIZED POWER AND HEAT GENERATING STEAM-GAS PLANT
    Biryuk, V. V.
    Larin, E. A.
    Livshits, M. Yu
    Shelud'ko, L. P.
    Shimanov, A. A.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2018, 91 (04) : 1029 - 1037
  • [30] Combining the nuclear power plant steam cycle with gas turbines
    Darwish, M. A.
    Al Awadhi, Fatimah M.
    Bin Amer, Anwar O.
    ENERGY, 2010, 35 (12) : 4562 - 4571