Flow Behavior of Heavy Silicone Oil During Eye Movements

被引:13
|
作者
Chan, Yau Kei [1 ,2 ]
Williams, Rachel L. [3 ]
Wong, David [1 ]
机构
[1] Univ Hong Kong, Li Ka Shing Fac Med, Dept Ophthalmol, Pokfulam, Hong Kong, Peoples R China
[2] Univ Hong Kong, Fac Engn, Dept Mech Engn, Hong Kong, Hong Kong, Peoples R China
[3] Univ Liverpool, Inst Ageing & Chron Dis, Dept Eye & Vis Sci, Liverpool, Merseyside, England
基金
英国工程与自然科学研究理事会;
关键词
emulsification; eye movements; heavy silicone oil; tamponade; RETINAL-DETACHMENT SURGERY; INTERNAL TAMPONADE; OXANE HD; INTRAOCULAR TAMPONADE; EMULSIFICATION;
D O I
10.1167/iovs.14-15439
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Currently there are various heavy silicone oil (HSO) tamponade agents available for treating inferior retinal diseases. Most of these HSO agents are either homogeneous liquids or a mixture of two components. Variations in their emulsification rates in vivo have been reported. In this study, we investigated their flow behaviors during eye-like movements. METHODS. A model eye chamber filled with various HSO agents was driven to perform eye-like movements. Five types of HSOs with different formulations together with 2 other tamponade agents were tested. Movements of various HSOs inside the chamber were captured by video recording and analyzed. RESULTS. Oxane HD has a larger movement and higher velocity relative to the eye chamber than the less viscous Densiron 68. The behavior of Densiron 68 is similar to that of homogeneous HSO 1.07 and HSO 1.20. Both Oxane HD and 11% silica fluid show very different behaviors compared to the other HSO agents. In addition, 11% silica fluid shows behavior similar to that of F6H8, a low-viscosity tamponade agent. CONCLUSIONS. The viscosity of HSO is not the sole parameter with which to determine the behavior of HSO during eye movements. Various HSOs that are manufactured by mixing different types of base SO and "heavy'' additives show distinct flow behaviors. The solubility and stability of the heavy additives in the base SO alter its flow when subjected to eye movements, which may contribute to in vivo emulsification.
引用
收藏
页码:8453 / 8457
页数:5
相关论文
共 50 条
  • [41] Eye blinks, eye movements and pupillary movements: Interrelationships during task performance
    Fukuda, K
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2004, 54 (1-2) : 53 - 53
  • [42] Refractive shift of silicone oil tamponade in pseudophakic eye
    Wei Fang
    Jiuke Li
    Xiaohong Jin
    Jing Zhai
    Yuanmin Dai
    Yumin Li
    BMC Ophthalmology, 16
  • [43] Biometry of the silicone oil-filled eye: II
    Murray, DC
    Durrani, OM
    Good, P
    Benson, MT
    Kirkby, GR
    EYE, 2002, 16 (06) : 727 - 730
  • [44] Biometry of the silicone oil-filled eye: II
    D C Murray
    O M Durrani
    P Good
    M T Benson
    G R Kirkby
    Eye, 2002, 16 : 727 - 730
  • [45] SILICONE OIL IN THE ANTERIOR-CHAMBER OF THE EYE - REPLY
    PAYLOR, RR
    PEYMAN, GA
    ARCHIVES OF OPHTHALMOLOGY, 1986, 104 (06) : 793 - 794
  • [46] Refractive shift of silicone oil tamponade in pseudophakic eye
    Fang, Wei
    Li, Jiuke
    Jin, Xiaohong
    Zhai, Jing
    Dai, Yuanmin
    Li, Yumin
    BMC OPHTHALMOLOGY, 2016, 16
  • [47] Management of endophthalmitis in a silicone oil-filled eye
    Zimmer-Galler, IE
    Santos, A
    Haller, JA
    Campochiaro, PA
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1997, 17 (06): : 507 - 509
  • [48] Wall slip behavior of alumina-silicone oil pastes during extrusion
    Graczyk, J
    Buggisch, LH
    Güner, S
    CHEMICAL ENGINEERING & TECHNOLOGY, 2001, 24 (05) : 489 - 491
  • [49] In situ study of phase behavior during heavy oil conversion
    Gray, Murray R.
    Bagheri, Seyed R.
    McCaffrey, William C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [50] Heavy Silicone Oil Tamponade for Complicated Retinal Detachment
    Yanyali, Ates
    Celik, Erkan
    Horozoglu, Fatih
    Nohutcu, Ahmet F.
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2007, 37 (04): : 274 - 279