Active Front End Motor-Drive System Operation under Power and Phase Loss

被引:0
|
作者
Sayed-Ahmed, Ahmed [1 ]
Seibel, Brian [1 ]
Kerkman, Russel J. [1 ]
机构
[1] Rockwell Automat, Stand Drives Business, Mequon, WI 53092 USA
关键词
Regenerative motor-drive systems; phase locked loop;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Active Front End "AFE" power converters are widely used in numerous renewable energy applications including but not limited to photovoltaic, wind power as well as industrial regenerative motor-drive systems. These power converters are extensively applied in industrial applications that mandate reduced input current harmonics and flexible bidirectional power flow. In spite of the fact that the power topology can be very similar in all of the above mentioned applications, the operating requirements and the control structure can widely vary based on each application. This paper is centered on analyzing the performance of the motor-drive systems and single phase operating conditions under voltage sag/ power loss ride through in regenerative motor-drive systems, and a novel power loss ride through algorithm is introduced to enable continuous operation of the drive under temporary power loss and phase loss conditions.
引用
收藏
页码:552 / 559
页数:8
相关论文
共 50 条
  • [31] Control of Open-Loop PWM Delta-Connected Motor-Drive Systems under One Phase Failure Condition
    Sayed-Ahmed, Ahmed
    Demerdash, Nabeel A. O.
    JOURNAL OF POWER ELECTRONICS, 2011, 11 (06) : 824 - 836
  • [32] Fault Tolerant Operation of Active Front End Converter with High Resistance Grounding System
    Da, Yao
    Gries, Mark
    Hermann, Colin
    2021 IEEE 19TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (PEMC), 2021, : 547 - 551
  • [33] Life cycle analysis of electrical motor-drive system based on electrical machine type
    Rassolkin, Anton
    Belahcen, Anouar
    Kallaste, Ants
    Vaimann, Toomas
    Vyachcslavovich Lukichev, Dmitry
    Orlova, Svetlana
    Heidari, Hamidreza
    Asad, Bilal
    Pando Acedo, Jaime
    PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2020, 69 (02) : 162 - 177
  • [34] A Comprehensive Analytical Power Loss Model of an Induction Motor Drive System with Loss Minimization Control
    Liu, Yiqi
    Bazzi, Ali M.
    2015 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2015, : 1638 - 1643
  • [35] Resonances in a high-power active-front-end rectifier system
    Rodríguez, JR
    Pontt, J
    Huerta, R
    Alzamora, G
    Becker, N
    Kouro, S
    Cortés, P
    Lezana, P
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (02) : 482 - 488
  • [36] A Multi-Pulse Front-End Rectifier System with Electronic Phase-Shifting for Harmonic Mitigation in Motor Drive Applications
    Zare, Firuz
    Davari, Pooya
    Blaabjerg, Frede
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [37] Development of a Switched-Reluctance Motor Drive With PFC Front End
    Chai, Jui-Yuan
    Liaw, Chang-Ming
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (01) : 30 - 42
  • [38] Reduced-switch induction motor drive system with active power decoupling
    Shi, Shuqi
    Sun, Yao
    Su, Mei
    Xie, Shiming
    Zhou, Min
    Li, Li
    IET ELECTRIC POWER APPLICATIONS, 2019, 13 (07) : 969 - 976
  • [39] Effects of Input Phase-Loss and Voltage Unbalance on Front end of Passive Low Harmonic Drive
    Govarthanan, R.
    Palanisamy, K.
    Paramasivam, S.
    Ramesh, P.
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [40] ON POWER STREAM IN MOTOR OR DRIVE SYSTEM
    Paszota, Zygmunt