Reliability and validity of the Stryd Power Meter during different walking conditions

被引:6
|
作者
Pinedo-Jauregi, Aitor [1 ]
Garcia-Tabar, Ibai [1 ,2 ]
Carrier, Bryson [3 ]
Navalta, James W. [3 ]
Camara, Jesus [1 ,2 ]
机构
[1] Univ Basque Country, Dept Phys Educ & Sport, Soc Sports & Phys Exercise Res Grp GIKAFIT, UPV EHU, Vitoria, Spain
[2] GIKAFIT, Biobara, Vitoria, Basque Country, Spain
[3] Univ Nevada, Dept Kinesiol & Nutr Sci, Las Vegas, NV 89154 USA
关键词
Wearable; Spatiotemporal parameters; Biomechanics; Accelerometer; Foot pod; LOAD CARRIAGE; RUNNING POWER; STATISTICAL-METHODS; PERFORMANCE; DISTANCE; IMPACT;
D O I
10.1016/j.gaitpost.2021.11.041
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: The Styrd Power Meter is gaining special interest for on-field gait analyses due to its low-cost and general availability. However, the reliability and validity of the Stryd during walking on positive slopes using different backpack loads have never been investigated.Research question: Is the Stryd Power Meter reliable and valid for quantifying gait mechanics during walking on positive inclines and during level walking incorporating load carriage?Methods: Seventeen participants from a police force rescue team performed 8 submaximal walking trials for 5 min at 3.6 km.h(- 1) during different positive slope (1%, 10% and 20%) and backpack load (0%, 10%, 20%, 30% and 40% of body mass) conditions. Two Stryd devices were utilized for reliability analyses. Validity of cadence and ground contact time (GCT) were analyzed against a gold standard device (Optojump).Results: The Stryd demonstrated acceptable reliability [mean bias: < 2.5%; effect size (ES): < 0.25; standard error of the mean: < 1.7%; r: > 0.76] for power, cadence, and GCT. Validity measures (mean bias: < 0.8%; ES: < 0.07; r: > 0.96; Lin's Concordance Coefficient: 0.96; Mean Absolute Percent Error: < 1%) for cadence were also found to be acceptable. The Stryd overestimated (P < 0.001; ES: > 5.1) GCT in all the walking conditions. A significant systematic positive bias (P < 0.022; r = 0.56-0.76) was found in 7 conditions.Significance: The Stryd Power Meter appears to produce reliable measurements for power output, cadence and GCT. The Stryd produced valid measurements for cadence during walking on positive slopes and during level walking with a loaded backpack. However, the Stryd is not valid for measuring GCT during these walking conditions. This study adds novel data regarding the reliability and validity of this device and might be of particular interest for scientists, practitioners, and first responders seeking reliable devices to quantify gait mechanics during walking.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 50 条
  • [1] Reliability of Trail Walking and Running Tasks Using the Stryd Power Meter
    Navalta, James Wilfred
    Montes, Jeffrey
    Bodell, Nathaniel G.
    Aguilar, Charli D.
    Radzak, Kara
    Manning, Jacob W.
    DeBeliso, Mark
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2019, 40 (08) : 498 - 502
  • [2] Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds
    Imbach, Frank
    Candau, Robin
    Chailan, Romain
    Perrey, Stephane
    [J]. SPORTS, 2020, 8 (07)
  • [3] VALIDITY AND RELIABILITY OF THE STAGES CYCLING POWER METER
    Granier, Cyril
    Hausswirth, Christophe
    Dorel, Sylvain
    Le Meur, Yann
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2020, 34 (12) : 3554 - 3559
  • [4] Reliability and Validity of the SHFT Running Power Meter
    Linkis, Jesper Emil
    Bonne, Thomas Christian
    Bejder, Jacob
    Rasmussen, Esben Krogh
    Breenfeldt Andersen, Andreas
    Nordsborg, Nikolai Baastrup
    [J]. SENSORS, 2021, 21 (22)
  • [5] ABSOLUTE RELIABILITY AND CONCURRENT VALIDITY OF THE STRYD SYSTEM FOR THE ASSESSMENT OF RUNNING STRIDE KINEMATICS AT DIFFERENT VELOCITIES
    Garcia-Pinillos, Felipe
    Roche-Seruendo, Luis E.
    Marcen-Cinca, Noel
    Marco-Contreras, Luis A.
    Latorre-Roman, Pedro A.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2021, 35 (01) : 78 - 84
  • [6] Validity And Reliability Of A Pedal-based Power Meter During Maximal Ergometer Testing
    Klapthor, Gibson A. E.
    Hutchison, Randolph E.
    Edwards, Karlee S.
    Knowles, Kristine E.
    Humes, Kelly A.
    Mocko, Gregory M.
    Vahidi, Ardalan
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 107 - 107
  • [7] Prediction of power output at different running velocities through the two-point method with the Stryd™ power meter
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Roche-Seruendo, Luis E.
    Garcia-Ramos, Amador
    [J]. GAIT & POSTURE, 2019, 68 : 238 - 243
  • [8] The Effects Of Walking Conditions On Reliability And Validity Of Two Types Of Pedometers
    Wise, Robin
    LaFarelle, Thomas
    Eldridge, James A.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S25 - S25
  • [9] The Reliability and Validity of the Loadsol® under Various Walking and Running Conditions
    Renner, Kristen E.
    Williams, D. S. Blaise
    Queen, Robin M.
    [J]. SENSORS, 2019, 19 (02)
  • [10] Validity and Reliability of the PowerTap P1 Pedals Power Meter
    Pallares, Jesus G.
    Ramon Lillo-Bevia, Jose
    [J]. JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2018, 17 (02) : 305 - 311