Reliability and Validity of the SHFT Running Power Meter

被引:1
|
作者
Linkis, Jesper Emil [1 ]
Bonne, Thomas Christian [1 ]
Bejder, Jacob [1 ]
Rasmussen, Esben Krogh [1 ]
Breenfeldt Andersen, Andreas [1 ]
Nordsborg, Nikolai Baastrup [1 ]
机构
[1] Univ Copenhagen, Dept Nutr Exercise & Sports NEXS, Fac Sci, Norre Alle 51, DK-2200 Copenhagen, Denmark
关键词
sports technology; sensors; wearable; running; exercise; training; testing; fitness device; gadget; OXYGEN-UPTAKE; STATISTICS NOTES; EXERCISE; VOLUME;
D O I
10.3390/s21227516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The SHFT device is a novel running wearable consisting of two pods connected to your smartphone issuing several running metrics based on accelerometer and gyroscope technology. The purpose of this study was to investigate the reliability and validity of the power output (PO) metric produced by the SHFT device. To assess reliability, 12 men ran on an outdoor track at 10.5 km & BULL;h(-1) and 12 km & BULL;h(-1) on two consecutive days. To assess validity, oxygen uptake (VO2) and SHFT data from eight men and seven women were collected during incremental submaximal running tests on an indoor treadmill on one to four separate days (34 tests in total). SHFT reliability on the outdoor track was strong with coefficients of variance (CV) of 1.8% and 2.4% for 10.5 and 12 km & BULL;h(-1), respectively. We observed a very strong linear relationship between PO and VO2 (r(2) = 0.54) within subjects, and a very strong linear relationship within each subject within each treadmill test (r(2) = 0.80). We conclude that SHFT provides a reliable running power estimate and that a very strong relationship between SHFT-Power and metabolic rate exists, which places SHFT as one of the leading commercially available running power meters.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] VALIDITY AND RELIABILITY OF THE STAGES CYCLING POWER METER
    Granier, Cyril
    Hausswirth, Christophe
    Dorel, Sylvain
    Le Meur, Yann
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2020, 34 (12) : 3554 - 3559
  • [2] SHFT the Way You Run: Evaluating the Validity of Digital Running Coaches
    Crain, Miriam
    Farish, Ellyssa
    Shakleford, Brianna
    Green, Makayla
    Rettinger, Vanessa
    Hammon, Nathan
    Keath, Adam
    [J]. RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2020, 91 : A48 - A48
  • [3] Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds
    Imbach, Frank
    Candau, Robin
    Chailan, Romain
    Perrey, Stephane
    [J]. SPORTS, 2020, 8 (07)
  • [4] Reliability of Trail Walking and Running Tasks Using the Stryd Power Meter
    Navalta, James Wilfred
    Montes, Jeffrey
    Bodell, Nathaniel G.
    Aguilar, Charli D.
    Radzak, Kara
    Manning, Jacob W.
    DeBeliso, Mark
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2019, 40 (08) : 498 - 502
  • [5] Reliability and validity of the Stryd Power Meter during different walking conditions
    Pinedo-Jauregi, Aitor
    Garcia-Tabar, Ibai
    Carrier, Bryson
    Navalta, James W.
    Camara, Jesus
    [J]. GAIT & POSTURE, 2022, 92 : 277 - 283
  • [6] Validity and Reliability of the PowerTap P1 Pedals Power Meter
    Pallares, Jesus G.
    Ramon Lillo-Bevia, Jose
    [J]. JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2018, 17 (02) : 305 - 311
  • [7] Validity and Reliability of the Garmin Vector Power Meter in Laboratory and Field Cycling
    Nimmerichter, Alfred
    Schnitzer, Lukas
    Prinz, Bernhard
    Simon, Dieter
    Wirth, Klaus
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (06) : 439 - 446
  • [8] Reliability Between Running Power Meter Footpods During Trials Of Submaximal Running On Three Different Surfaces
    Shearer, Lee
    Hayden, Nicholas
    Lara, Frank
    Coppi, Mason
    Ogden, Jake
    Murr, Scott
    Sobolewski, Eric
    Hutchison, Randolph E.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 436 - 436
  • [9] The Validity and Reliability of a Tire Pressure-Based Power Meter for Indoor Cycling
    Fiolo, Nicholas J.
    Lu, Hai-Ying
    Chen, Chia-Hsiang
    Fuchs, Philip X.
    Chen, Wei-Han
    Shiang, Tzyy-Yuang
    [J]. SENSORS, 2021, 21 (18)
  • [10] Test-retest reliability and validity of the Stages mountain bike power meter
    Costa, Vitor P.
    Tramontin, Artur F.
    Visentainer, Luis Henrique
    Borszcz, Fernando K.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2019, 27 (01) : 55 - 61