Digital breast tomosynthesis versus digital mammography: a clinical performance study

被引:206
|
作者
Gennaro, Gisella [1 ]
Toledano, Alicia [2 ]
di Maggio, Cosimo [3 ]
Baldan, Enrica [1 ]
Bezzon, Elisabetta [1 ]
La Grassa, Manuela [4 ]
Pescarini, Luigi [1 ,3 ]
Polico, Ilaria [1 ]
Proietti, Alessandro [1 ]
Toffoli, Aida [1 ]
Muzzio, Pier Carlo [1 ,5 ]
机构
[1] IRCCS, Venetian Oncol Inst IOV, Dept Radiol, I-35128 Padua, Italy
[2] Stat Collaborat Inc, Washington, DC USA
[3] Univ Padua, Dept Oncol & Surg Sci, Padua, Italy
[4] IRCCS, Aviano Oncol Reference Ctr CRO, Dept Radiol, Aviano, Pordenone, Italy
[5] Univ Padua, Dept Med Diagnost Sci, Padua, Italy
关键词
Digital breast tomosynthesis; Digital mammography; ROC analysis; Clinical performance; Non-inferiority; COMPUTER-AIDED DETECTION; RADIATION; SYSTEM; EXPERIENCE; SIMULATION; ACCURACY; PLATFORM; MASSES;
D O I
10.1007/s00330-009-1699-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the clinical performance of digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) in a diagnostic population. The study enrolled 200 consenting women who had at least one breast lesion discovered by mammography and/or ultrasound classified as doubtful or suspicious or probably malignant. They underwent tomosynthesis in one view [mediolateral oblique (MLO)] of both breasts at a dose comparable to that of standard screen-film mammography in two views [craniocaudal (CC) and MLO]. Images were rated by six breast radiologists using the BIRADS score. Ratings were compared with the truth established according to the standard of care and a multiple-reader multiple-case (MRMC) receiver-operating characteristic (ROC) analysis was performed. Clinical performance of DBT compared with that of FFDM was evaluated in terms of the difference between areas under ROC curves (AUCs) for BIRADS scores. Overall clinical performance with DBT and FFDM for malignant versus all other cases was not significantly different (AUCs 0.851 vs 0.836, p = 0.645). The lower limit of the 95% CI or the difference between DBT and FFDM AUCs was -4.9%. Clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views.
引用
收藏
页码:1545 / 1553
页数:9
相关论文
共 50 条
  • [41] Clinical implementation of synthesized mammography with digital breast tomosynthesis in a routine clinical practice
    Phoebe E. Freer
    Joanna Riegert
    Laura Eisenmenger
    Dominik Ose
    Nicole Winkler
    Matthew A. Stein
    Gregory J. Stoddard
    Rachel Hess
    [J]. Breast Cancer Research and Treatment, 2017, 166 : 501 - 509
  • [42] COMPARISON BETWEEN DIGITAL MAMMOGRAPHY AND DIGITAL BREAST TOMOSYNTHESIS IN THE DIAGNOSIS OF BREAST CANCER
    Jari, Irina
    Naum, A. G.
    Gheorghe, Liliana
    Negru, D.
    Ursaru, Manuela
    [J]. MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2019, 123 (01): : 102 - 108
  • [43] Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis
    Alabousi, Mostafa
    Wadera, Akshay
    Al-Ghita, Mohammed Kashif
    Al-Ghetaa, Rayeh Kashef
    Salameh, Jean-Paul
    Pozdnyakov, Alex
    Zha, Nanxi
    Samoilov, Lucy
    Sharifabadi, Anahita Dehmoobad
    Sadeghirad, Behnam
    Freitas, Vivianne
    McInnes, Matthew D. F.
    Alabousi, Abdullah
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2021, 113 (06) : 680 - 690
  • [44] Comparison of Tomosynthesis Plus Digital Mammography and Digital Mammography Alone for Breast Cancer Screening
    Haas, Brian M.
    Kalra, Vivek
    Geisel, Jaime
    Raghu, Madhavi
    Durand, Melissa
    Philpotts, Liane E.
    [J]. RADIOLOGY, 2013, 269 (03) : 694 - 700
  • [45] Generative compressed breast shape model for digital mammography and digital breast tomosynthesis
    Pinto, Marta C.
    Michielsen, Koen
    Biniazan, Ramyar
    Kappler, Steffen
    Sechopoulos, Ioannis
    [J]. MEDICAL PHYSICS, 2023, 50 (05) : 2928 - 2938
  • [46] Multireader comparison of contrast-enhanced mammography versus the combination of digital mammography and digital breast tomosynthesis in the preoperative assessment of breast cancer
    Rossano Girometti
    Anna Linda
    Paola Conte
    Michele Lorenzon
    Isabella De Serio
    Katerina Jerman
    Viviana Londero
    Chiara Zuiani
    [J]. La radiologia medica, 2021, 126 : 1407 - 1414
  • [47] Multireader comparison of contrast-enhanced mammography versus the combination of digital mammography and digital breast tomosynthesis in the preoperative assessment of breast cancer
    Girometti, Rossano
    Linda, Anna
    Conte, Paola
    Lorenzon, Michele
    De Serio, Isabella
    Jerman, Katerina
    Londero, Viviana
    Zuiani, Chiara
    [J]. RADIOLOGIA MEDICA, 2021, 126 (11): : 1407 - 1414
  • [48] Digital Mammography versus Breast Tomosynthesis: Impact of Breast Density on Diagnostic Performance in Population-based Screening
    Osteras, Bjorn Helge
    Martinsen, Anne Catrine T.
    Gullien, Randi
    Skaane, Per
    [J]. RADIOLOGY, 2019, 293 (01) : 60 - 68
  • [49] Interval cancer in the Córdoba Breast Tomosynthesis Screening Trial (CBTST): comparison of digital breast tomosynthesis plus digital mammography to digital mammography alone
    Pulido-Carmona, Cristina
    Romero-Martin, Sara
    Raya-Povedano, Jose Luis
    Cara-Garcia, Maria
    Font-Ugalde, Pilar
    Elias-Cabot, Esperanza
    Pedrosa-Garriguet, Margarita
    Alvarez-Benito, Marina
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (8) : 5427 - 5438
  • [50] Digital Breast Tomosynthesis: Observer Performance Study
    Gur, David
    Abrams, Gordon S.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Perrin, Ronald L.
    Rathfon, Grace Y.
    Sumkin, Jules H.
    Zuley, Margarita L.
    Bandos, Andriy I.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) : 586 - 591