Performance analysis of melting phenomena in an ice-freezing type direct-contact heat exchanger

被引:5
|
作者
Patel, Parth [1 ]
Sharma, Amrita [1 ]
Monde, Aniket D. [1 ]
Sharma, Manvendra [2 ]
Mondal, Bobin [2 ]
Kothadia, Hardik B. [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Jodhpur 342037, Rajasthan, India
[2] DRDO, Def Lab Jodhpur, Jodhpur, Rajasthan, India
关键词
Phase change material; Direct-contact heat exchanger; Melting; Performance analysis; PHASE-CHANGE MATERIALS; ELECTRIC VEHICLE-BATTERY; THERMAL-ENERGY STORAGE; SPECIES TRANSPORT; CHARGING PROCESS; CONTINUUM MODEL; CHANGE SYSTEMS; SIMULATION; SOLIDIFICATION; FLOW;
D O I
10.1016/j.est.2022.104575
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present study endeavours to represent a latest concept of utilizing similar heat transfer fluid (HTF) and phase change material (PCM) in a direct contact type PCM heat exchanger (DCHEX). This technique has been found more effective during melting process. In the following investigation, a segment of the heat exchanger is numerically modelled to analyse the temporal behaviour of the latent heat energy storage system during the cycle of discharging. The transient numerical computation incorporates an iterative, finite volume method based on enthalpy-porosity technique for numerically model the phase change phenomena. For the analysis, water is used as working fluid. To show the performance enhancement of this technique during melting process, a series of simulations are performed to examine the impact of varying HTF inlet condition and flow rates. The changes in the configuration of the heat exchanger are studied. Heat exchanger parameters such as difference between inlet and outlet temperature (& UDelta;T), heat release rate (Q), temperature effectiveness (theta) and volumetric heat transfer coefficient (Uv) are evaluated for all such cases. A uniform exit temperature of the HTF is observed for most of the time with significant increase in the heat transfer in the direct contact type heat exchanger. Three distinct stages namely initial, intermediate and final phases are observed during the melting process. During the initial phase the parameters exhibits uniform behaviour. In the intermediate phase there is significant drop and rise in the parameters while during the final phase the value of parameters diminishes except for Uv. Increasing HTF flow rate promotes increment in heat transfer rate while increasing the inlet temperature of HTF is more desirable to increase the overall heat transfer coefficient.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Direct-Contact Air, Gravel, Ground Heat Exchanger in Air Treatment Systems for Cowshed Air Conditioning
    Besler, Maciej
    Cepinski, Wojciech
    Keskiewicz, Piotr
    [J]. ENERGIES, 2022, 15 (01)
  • [32] Experimental and simulation study on heat and mass transfer characteristics in direct-contact total heat exchanger for flue gas heat recovery
    Wei, Hongyang
    Huang, Shifang
    Zhang, Xiaosong
    [J]. APPLIED THERMAL ENGINEERING, 2022, 200
  • [33] Performance analysis of a direct-contact thermal energy storage-solidification
    Kiatsiriroat, T
    Tiansuwan, J
    Suparos, T
    Thalang, KN
    [J]. RENEWABLE ENERGY, 2000, 20 (02) : 195 - 206
  • [34] Numerical Simulation on Enhanced Heat Transfer and Flow Characteristics in Direct-Contact Heat Exchanger: A Novel Kenics Static Mixer
    Zhao, Shuang
    Zhang, Xia
    Wang, Hua
    Zhang, Hao
    Huang, Junwei
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2023, 2023
  • [35] Experimental assessment of a direct-contact water in a cooler liquid gallium bath heat exchanger bubbling hot
    Al Omari, S. -A. B.
    Bashir, A. A. K.
    Al Hammadi, M. I.
    Al Hamalawi, F. J.
    Elnajjar, E.
    Ghazal, A. M.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 86 : 71 - 80
  • [36] HEAT-TRANSFER PHENOMENON IN THE REGION OF DISPERSED PHASE INJECTION IN A DIRECT-CONTACT LIQUID-LIQUID HEAT-EXCHANGER
    CULBRETH, W
    MARSCHALL, E
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1983, 10 (03) : 211 - 223
  • [37] PERFORMANCE OF DIRECT-CONTACT LATENT-HEAT STORAGE UNITS WITH 2 HYDRATED SALTS
    FARID, MM
    KHALAF, AN
    [J]. SOLAR ENERGY, 1994, 52 (02) : 179 - 189
  • [38] Heat transfer enhancement and melting behavior of phase change material in a direct-contact thermal energy storage container
    He, Shiquan
    Wang, Weilong
    Wei, Linhao
    Ding, Jing
    [J]. JOURNAL OF ENERGY STORAGE, 2020, 31
  • [39] Performance of direct-contact heat and mass exchangers with steam-gas mixtures at subatmospheric pressures
    DeAndres, MC
    Hoo, E
    Zangrando, F
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (05) : 965 - 973
  • [40] Melting and Solidification Characteristic of Mixture of Two Types of Latent Heat Storage Material in Direct Contact Heat Exchanger
    Yu, Jiksu
    Horibe, Akihiko
    Haruki, Naoto
    [J]. EXPERIMENTAL HEAT TRANSFER, 2024,