Which inverter drives need upgraded motor stator windings

被引:6
|
作者
Stone, GC [1 ]
Campbell, SR [1 ]
Lloyd, BA [1 ]
Tetreault, S [1 ]
机构
[1] Iris Power Engn Inc, Unit 2, Toronto, ON M9C 1B2, Canada
关键词
D O I
10.1109/PCICON.2000.882771
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Random wound stator windings in motors operating in refining and petrochemical plants have failed when exposed to the fast-risetime voltage surges coming from inverters. Studies show that the failure is due to a combination of bad luck in specific motor installations (resonance phenomena caused by power cable length and surge impedance ratios) together with the fact that modern inverter-fed drives (IFDs) create tens of thousands of surges per second with risetimes as fast as 50 ns. Measurements on motors show that these surges create partial discharges (also called corona), and these discharges eventually destroy the turn-to-turn and/or phase-to-phase insulation, resulting in premature motor failure. This paper discusses the specific mechanisms involved in the stator winding failure due to IFDs and presents the measurements and analysis from surge monitoring installed on many different motors. Although some motors may experience short risetime, high magnitude surges, most motors experience either low magnitude and/or long risetime surges, which are relatively harmless. Usually several different magnitudes and risetimes are present from the same IFD. Thus it seems that conventional motor stators can be safely used in many (but not all) IFD applications. Methods are presented to determine when special IFD duty motors are needed. Surge voltage tests, as well as partial discharge tests can help the user insure that motors can successfully operate in severe applications.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [31] Measurement and analysis of partial discharge in high voltage motor stator windings
    Kim, HD
    Ju, YH
    [J]. PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING TECHNOLOGY CONFERENCE, 2003, : 27 - 31
  • [32] Modelling of Asynchronous Motor with Split Stator Windings on the Principle of a Rotary Autotransformer
    Kaplun, Viktor
    Makarevych, Svitlana
    Chuenko, Roman
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (03): : 39 - 43
  • [33] Analysis of a polyphase synchronous reluctance motor with two identical stator windings
    Obe, ES
    Senjyu, T
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (6-7) : 515 - 524
  • [35] Stator resistance compensation method for induction motor drives
    Cheng, KWE
    [J]. SEVENTH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND VARIABLE SPEED DRIVES, 1998, (456): : 127 - 132
  • [36] Z-source inverter for motor drives
    Peng, FZ
    [J]. PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 249 - 254
  • [37] Motor winding problems - Caused by inverter drives
    Fenger, M
    Campbell, SR
    Pedersen, J
    [J]. IEEE INDUSTRY APPLICATIONS MAGAZINE, 2003, 9 (04) : 22 - 31
  • [38] Z-source inverter for motor drives
    Peng, FZ
    Joseph, A
    Wang, J
    Shen, MS
    Chen, LH
    Pan, ZG
    Ortiz-Rivera, E
    Huang, Y
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) : 857 - 863
  • [39] A Literature Review on Open End Windings Induction Motor Drives
    Reddy, K. Sudarshan
    Baskar, S.
    [J]. 2021 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, COMMUNICATION, COMPUTER TECHNOLOGIES AND OPTIMIZATION TECHNIQUES (ICEECCOT), 2021, : 395 - 398
  • [40] Peak Voltage Stress on Stator Winding in PWM Inverter fed Drives
    Sundeep, Shubham
    Wang, Jiabin
    Griffo, Antonio
    Alvarez-Gonzalez, Fernando
    [J]. 2020 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), VOL 1, 2020, : 1579 - 1585