Effect of coronal fracture angle on the stability of screw fixation in medial malleolar fractures: A finite element analysis

被引:5
|
作者
Emre, Tuluhan Yunus [1 ]
Celik, Huseyin Kursat [2 ]
Arik, Hasan O. [3 ]
Rennie, Allan E. W. [4 ]
Kose, Ozkan [3 ]
机构
[1] Biruni Univ, Med Fac, Orthopaed & Traumatol Dept, Istanbul, Turkey
[2] Akdeniz Univ, Dept Agr Machinery & Technol Engn, TR-07070 Antalya, Turkey
[3] Antalya Training & Res Hosp, Orthopaed & Traumatol Dept, Antalya, Turkey
[4] Univ Lancaster, Engn Dept, Lancaster, England
关键词
Medial malleolus fracture; fracture angle; fixation; finite element analysis; biomechanics; VERTICAL SHEAR FRACTURES; HUMAN CORTICAL BONE; ARTICULAR-CARTILAGE; COMPUTED-TOMOGRAPHY; INTERNAL-FIXATION; ANKLE FRACTURES; TRABECULAR BONE; THICKNESS; CONTACT; PLATE;
D O I
10.1177/09544119221089723
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a 'critical fracture angle' to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30 degrees and 90 degrees, in 5 degrees increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 mu m between fracture fragments at fracture angles of 30 degrees and 90 degrees were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 mu m between fracture fragments at fracture angles of 90 degrees and 35 degrees, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30 degrees-90 degrees. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 mu m by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70 degrees angle with the tibial plafond results in a significant articular separation ( > 100 mu m) during single-leg stand. Below this critical angle of 70 degrees, two screws provide sufficient fixation. [GRAPHICS] .
引用
收藏
页码:825 / 840
页数:16
相关论文
共 50 条
  • [41] Cannulated screw and Kirschner fixation for the treatment of medial and lateral malleolar epiphyseal fractures in children: a retrospective study of 36 cases
    Linjun Jiang
    Jun Wu
    Ming Li
    Xing Liu
    Cong Luo
    Xiangyang Qu
    Journal of Orthopaedic Surgery and Research, 14
  • [42] Comprehensive biomechanical analysis of three clinically used fixation constructs for posterior malleolar fractures using cadaveric and finite element analysis
    Anwar, Adeel
    Hu, Zhenwei
    Adnan, Atif
    Gao, Yanming
    Li, Bing
    Nazir, Muhammad Umar
    Tian, Cong
    Wang, Yanfeng
    Lv, Decheng
    Zhao, Zhi
    Zhang, Zhen
    Zhang, Hu
    Tong, Changgui
    Lv, Gang
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [43] Comprehensive biomechanical analysis of three clinically used fixation constructs for posterior malleolar fractures using cadaveric and finite element analysis
    Adeel Anwar
    Zhenwei Hu
    Atif Adnan
    Yanming Gao
    Bing Li
    Muhammad Umar Nazir
    Cong Tian
    Yanfeng Wang
    Decheng Lv
    Zhi Zhao
    Zhen Zhang
    Hu Zhang
    Changgui Tong
    Gang Lv
    Scientific Reports, 10
  • [44] The effect of body weight on interfragmentary fracture strain in plate fixation of distal femur fractures: A finite element analysis
    Shah, Ishan D.
    Schlauch, Adam M.
    Phan, Lisa
    Han, Jiho
    Eng, Oluwatodimu Richard Raji M.
    Farrell, Brian
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (06)
  • [45] Finite element analysis of the indirect reduction of posterior pedicle screw fixation for a thoracolumbar burst fracture
    Song, Yuanzheng
    Pang, Xia
    Zhu, Fahao
    MEDICINE, 2022, 101 (41) : E30965
  • [46] Traditional and bionic dynamic hip screw fixation for the treatment of intertrochanteric fracture: a finite element analysis
    Cun, Yunwei
    Dou, Chenhou
    Tian, Siyu
    Li, Ming
    Zhu, Yanbin
    Cheng, Xiaodong
    Chen, Wei
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (03) : 551 - 559
  • [47] Traditional and bionic dynamic hip screw fixation for the treatment of intertrochanteric fracture: a finite element analysis
    Yunwei Cun
    Chenhou Dou
    Siyu Tian
    Ming Li
    Yanbin Zhu
    Xiaodong Cheng
    Wei Chen
    International Orthopaedics, 2020, 44 : 551 - 559
  • [48] Effect of interfragmentary gap on the mechanical behavior of mandibular angle fracture with three fixation designs: A finite element analysis
    Wang, Russell
    Liu, Yunfeng
    Wang, Joanne Helen
    Baur, Dale Allen
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2017, 70 (03): : 360 - 369
  • [49] Comparison of stability of titanium and absorbable plate and screw fixation for mandibular angle fractures
    Esen, Alparslan
    Ataoglu, Hanife
    Gemi, Lokman
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (06): : 806 - 811
  • [50] Enhancing fixation stability in proximal humerus fractures: screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing
    Liu, Jichao
    Zhang, Ziyan
    Li, Peng
    Piao, Chengdong
    SCIENTIFIC REPORTS, 2024, 14 (01):