Effect of coronal fracture angle on the stability of screw fixation in medial malleolar fractures: A finite element analysis

被引:5
|
作者
Emre, Tuluhan Yunus [1 ]
Celik, Huseyin Kursat [2 ]
Arik, Hasan O. [3 ]
Rennie, Allan E. W. [4 ]
Kose, Ozkan [3 ]
机构
[1] Biruni Univ, Med Fac, Orthopaed & Traumatol Dept, Istanbul, Turkey
[2] Akdeniz Univ, Dept Agr Machinery & Technol Engn, TR-07070 Antalya, Turkey
[3] Antalya Training & Res Hosp, Orthopaed & Traumatol Dept, Antalya, Turkey
[4] Univ Lancaster, Engn Dept, Lancaster, England
关键词
Medial malleolus fracture; fracture angle; fixation; finite element analysis; biomechanics; VERTICAL SHEAR FRACTURES; HUMAN CORTICAL BONE; ARTICULAR-CARTILAGE; COMPUTED-TOMOGRAPHY; INTERNAL-FIXATION; ANKLE FRACTURES; TRABECULAR BONE; THICKNESS; CONTACT; PLATE;
D O I
10.1177/09544119221089723
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Malleolar screw fixation is the most widely used treatment method for medial malleolar (MM) fractures. Here, although buttress plate fixation is advocated for vertical MM fractures, the angular discrimination between oblique and vertical MM fractures is still not fully understood. The purpose of this study is to test the adequacy of screw fixation in MM fractures with different angles and determination of a 'critical fracture angle' to guide surgeons in the decision-making for screw fixation for MM fractures by utilizing an advanced engineering simulation approach. In addition to loading of the healthy tibia structure, various cases of the MM fracture double screw fixation (14 simulation scenarios in total with fracture angles between 30 degrees and 90 degrees, in 5 degrees increments) were considered in this research and their static loading conditions just after fixation operation were simulated through nonlinear (geometric and contact nonlinearity) finite element analysis (FEA). Patient-specific computed tomography scan data, parametric three-dimensional solid modelling and finite element method (FEM) based engineering codes were employed in order to simulate the fixation scenarios. Visual and numerical outputs for the deformation and stress distributions, separation and sliding behaviours of the MM fracture fragments of various screw fixations were clearly exhibited through FEA results. Minimum and maximum separation distances (gap) of 3.75 and 150.34 mu m between fracture fragments at fracture angles of 30 degrees and 90 degrees were calculated respectively against minimum and maximum sliding distances of 25.87 and 41.37 mu m between fracture fragments at fracture angles of 90 degrees and 35 degrees, respectively. The FEA results revealed that while the separation distance was increasing, the sliding distance was decreasing and there were no distinct differences in sliding distances in the scenarios from fracture angles of 30 degrees-90 degrees. The limitations and errors in a FEA study are inevitable, however, it was interpreted that the FEA scenarios were setup in this study by utilizing acceptable assumptions providing logical outputs under pre-defined boundary conditions. Finally, the fracture healing threshold for separation and/or sliding distance between fracture fragments was assigned as 100 mu m by referring to previous literature and it was concluded that the screws fixed perpendicular to the fracture in a MM fracture with more than 70 degrees angle with the tibial plafond results in a significant articular separation ( > 100 mu m) during single-leg stand. Below this critical angle of 70 degrees, two screws provide sufficient fixation. [GRAPHICS] .
引用
收藏
页码:825 / 840
页数:16
相关论文
共 50 条
  • [1] FINITE ELEMENT ANALYSIS OF FIXED MEDIAL MALLEOLAR FRACTURES
    Chande, Ruchi D.
    Owen, John R.
    Adelaar, Robert S.
    Wayne, Jennifer S.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT B, 2014,
  • [2] Cross-Screw Fixation in Isolated Medial Malleolar Fractures
    Esenyel, Cem Zeki
    Demir, Tugcan
    Karaca, Halil
    Kalkar, Ismail
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2024, 114 (05)
  • [3] Biomechanical Comparison of Locking Plate and Cancellous Screw Techniques in Medial Malleolar Fractures: A Finite Element Analysis
    Jiang, Dajun
    Zhan, Shi
    Wang, Qing
    Ling, Ming
    Hu, Hai
    Jia, Weitao
    JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (06): : 1138 - 1144
  • [4] Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures
    May, Hasan
    Kati, Yusuf Alper
    Gumussuyu, Gurkan
    Emre, Tuluhan Yunus
    Unal, Melih
    Kose, Ozkan
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 21 (01)
  • [5] Bioabsorbable magnesium screw versus conventional titanium screw fixation for medial malleolar fractures
    Hasan May
    Yusuf Alper Kati
    Gurkan Gumussuyu
    Tuluhan Yunus Emre
    Melih Unal
    Ozkan Kose
    Journal of Orthopaedics and Traumatology, 2020, 21
  • [6] Biomechanical study of biodegradable screw fixation of medial malleolar fracture.
    Hansen, T
    Mukherjee, DP
    Mayeux, RH
    Ogden, AL
    Sadasivan, KK
    Albright, JA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U504 - U505
  • [7] Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis
    Yang, Pan
    Zhang, Ying
    Liu, Jian
    Xiao, Jin
    Ma, Li Min
    Zhu, Chang Rong
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (02) : 203 - 209
  • [8] Does lag screw fixation of condylar fractures result in adequate stability? A finite element analysis
    Conci, Ricardo Augusto
    Garbin, Eleonor Alvaro, Jr.
    Griza, Geraldo Luiz
    Ernica, Natasha Magro
    Noritomi, Pedro Yoshito
    Silveira Tomazi, Flavio Henrique
    Fritscher, Guilherme Genehr
    Heitz, Claiton
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (06) : 1041 - 1045
  • [9] Single-Screw Fixation Compared With Double Screw Fixation for Treatment of Medial Malleolar Fractures: A Prospective Randomized Trial
    Buckley, Richard
    Kwek, Ernest
    Duffy, Paul
    Korley, Robert
    Puloski, Shannon
    Buckley, Andrew
    Martin, Ryan
    Moller, Emilia Rydberg
    Schneider, Prism
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (11) : 548 - 553
  • [10] The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis
    Durusoy, Serhat
    Oner, Kerim
    Ozer, Alaattin
    Sevinc, Huseyin Fatih
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (01): : 75 - 84