MRIgRT dynamic lung motion thorax anthropomorphic QA phantom: Design, development, reproducibility, and feasibility study

被引:15
|
作者
Steinmann, A. [1 ]
Alvarez, P. [1 ]
Lee, H. [1 ]
Court, L. [1 ]
Stafford, R. [2 ]
Sawakuchi, G. [1 ]
Wen, Z. [1 ]
Fuller, C. [3 ]
Followill, D. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
关键词
end-to-end QA phantom; MR Linac; MR; CT phantom; MRgRT phantom; MRIgRT phantom; QUALITY;
D O I
10.1002/mp.13757
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo design, manufacture, and evaluate a dynamic magnetic resonance imaging/computed tomography (MRI/CT)-compatible anthropomorphic thorax phantom used to credential MR image-guided radiotherapy (MRIgRT) systems participating in NCI-sponsored clinical trials. MethodThe dynamic anthropomorphic thorax phantom was constructed from a water-fillable acrylic shell that contained several internal structures representing radiation-sensitive organs within the thoracic region. A custom MR/CT visible cylindrical insert was designed to simulate the left lung with a centrally located tumor target. The surrounding lung tissue was constructed from a heterogeneous in-house mixture using petroleum jelly and miniature (2-4 mm diameter) styrofoam balls and the tumor structure was manufactured from liquid PVC plastic. An MR conditional pneumatic system was developed to allow the MRIgRT insert to move in similar inhale/exhale motions. TLDs and radiochromic EBT3 film were inserted into the phantom to measure absolute point doses and dose distributions, respectively. The dynamic MRIgRT thorax phantom was evaluated through a reproducibility study and a feasibility study. Comprehensive end-to-end examinations were done where the phantom was imaged on a CT, an IMRT treatment plan was created and an MR image was captured to verify treatment setup. Then, the phantom was treated on an MRIgRT system. The reproducibility study evaluated how well the phantom could be reproduced in an MRIgRT system by irradiating three times on an Elekta's 1.5 T Unity system. The phantom was shipped to three independent institutions and was irradiated on either an MRIdian cobalt-60 (Co-60) or an MRIdian linear accelerator system. Treatment evaluations used TLDs and radiochromic film to compare the planned treatment reported on the treatment planning software against the measured dose on the dosimeters. ResultsThe phantom on the Unity system had reproducible TLD doses measurements (SD < 1.5%). The measured TLD to calculated dose ratios from the reproducibility and feasibility studies ranged from 0.93 to 1.01 and 0.96 to 1.03, respectively. Using a 7%/5 mm gamma analysis criteria, the reproducibility and feasibility studies resulted in an average passing rate of 93.3% and 96.8%, respectively. No difference was noted in the results between the MRIdian Co-60 and MRIdian 6 MV linac delivery to the phantom and all treatment evaluations were within IROC-Houston's acceptable criterion. ConclusionsA dosimetrically tissue equivalent, CT/MR visible, motion-enabled anthropomorphic MRIgRT thorax phantom was constructed to simulate a lung cancer patient and was evaluated as an appropriate NIH credentialing tool used for MRIgRT systems.
引用
收藏
页码:5124 / 5133
页数:10
相关论文
共 20 条
  • [1] MRIgRT head and neck anthropomorphic QA phantom: Design, development, reproducibility, and feasibility study
    Steinmann, A.
    Alvarez, P.
    Lee, H.
    Court, L.
    Stafford, R.
    Sawakuchi, G.
    Wen, Z.
    Fuller, C. D.
    Followill, D.
    MEDICAL PHYSICS, 2020, 47 (02) : 604 - 613
  • [2] The Design and Fabrication of a Dynamic Anthropomorphic Thorax Phantom
    Xu, Z.
    Sun, Z.
    Shi, X.
    Lin, C.
    Lu, W.
    Lu, W.
    Qiu, J.
    Shi, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E556 - E557
  • [3] Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [4] dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3281 - S3285
  • [5] Evaluation of a novel anthropomorphic thorax phantom with a dynamic lung using 4DCT
    Lustermans, Didier
    Abdulrahim, Roua
    Reniers, Brigitte
    Verhaegen, Frank
    Fonseca, Gabriel Paiva
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3273 - S3275
  • [6] Assessment of the dose distribution of Minibeam radiotherapy for lung tumors in an anthropomorphic phantom: A feasibility study
    Zeinali-Rafsanjani, Banafsheh
    Mosleh-Shirazi, Mohammad Amin
    Haghighatafshar, Mahdi
    Jalli, Reza
    Saeedi-Moghadam, Mahdi
    TECHNOLOGY AND HEALTH CARE, 2017, 25 (04) : 683 - 692
  • [7] A Computational Phantom of the Thorax Combining Anatomical and Respiratory Motion Models: Feasibility Study and Preliminary Developments
    Seregni, M.
    Riboldi, M.
    Baroni, G.
    Sharp, G.
    MEDICAL PHYSICS, 2017, 44 (06) : 3025 - 3025
  • [8] Anthropomorphic phantom for effective dose measurements:: Feasibility numerical study and presentation of the detector development
    Villagrasa, C.
    Darreon, J.
    Clairand, I.
    Queinnec, F.
    Furstoss, C.
    Bottollier-Depois, J. F.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 590 - 593
  • [9] Development of a novel 3D-printed dynamic anthropomorphic thorax phantom for evaluation of four-dimensional computed tomography
    Lustermans, Didier
    Abdulrahim, Roua
    Taasti, Vicki Trier
    Szkitsak, Juliane
    Svegzdaite, Evita
    Clarkin, Sarina
    Reniers, Brigitte
    Verhaegen, Frank
    Fonseca, Gabriel Paiva
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [10] Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study
    Shih-Neng Yang
    Chun-Wei Lin
    Mu-Bai Chang
    Geoffrey G. Zhang
    Kuei-Ting Chou
    Yu-Rou Chiou
    Shung-Shung Sun
    Louis Lui
    Tsung-Jung Ho
    Tzung-Chi Huang
    Journal of Medical and Biological Engineering, 2018, 38 : 46 - 54