Evaluation of EBT-2 model GAFCHROMIC™ film performance in water

被引:29
|
作者
Aldelaijan, Saad [1 ,2 ]
Devic, Slobodan [1 ,2 ]
Mohammed, Huriyyah [1 ,2 ]
Tomic, Nada [1 ,2 ]
Liang, Li-Heng [1 ,2 ]
DeBlois, Francois [1 ,2 ]
Seuntjens, Jan [1 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
[2] McGill Univ, SMBD Jewish Gen Hosp, Dept Radiat Oncol, Montreal, PQ H3T 1E2, Canada
关键词
radiochromic film dosimetry; water immersion; RADIOCHROMIC FILM; DOSIMETRY;
D O I
10.1118/1.3455713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors present results of the measurements on the impact of radiochromic film immersion in water. The impact of film piece size, initial optical density, postimmersion waiting time prior to scanning, and the time film was kept in water has been investigated. The authors also investigated the pathways of water penetration into the film during the film immersion in water. Methods: To study the impact of water immersion on change in optical density, the authors used various sizes of the latest EBT-2 model GAFCHROMIC (TM) film: 2 X 2, 4 X 4, and 8 X 8 in.(2). In addition, to test any existing dependence of the film's optical density on water diffusion, the authors used two sets of films: Unexposed (0 Gy) and film pieces exposed to a dose of 3 Gy. Times that film pieces were left in water ranged from 30 min to 24 h, and once the film was permanently removed from water, the authors also studied the impact of the scanning time (Delta t) that ranged from 0 (films scanned right after removal from water) to 72 h postimmersion. Results: While the penetration depth can reach as much as 9 mm around the edges of the EBT-2 GAFCHROMIC T film, the anticipated dose error due to the change in optical density due to the water immersion appears to be negligible for the short immersions of the order of 30 min. However, as the immersion time increases, the anticipated dose error may reach 22 cGy on a 2 X 2 in.(2) piece of film, which corresponds to 7% dose error at 3 Gy of measured dose. Conclusions: In this work, the authors report on an undoubted impact of radiochromic film immersion in water on the measured change in optical density, which may lead to systematic errors in dose measurements if the film is kept in water for longer periods of time. The magnitude of the impact depends on many parameters: Size of the film piece, initial optical density, postimmersion waiting time prior to scanning (defined by the current radiochromic film dosimetry protocol in place), and the time film was kept in water. The authors also suggested various approaches in correcting for the change in netOD due to water penetration into the film, but the authors believe that the use of the control film piece would be the most appropriate. (c) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3455713]
引用
收藏
页码:3687 / 3693
页数:7
相关论文
共 50 条
  • [31] Dose Response Characteristics of the New EBT-2 Film for Different Megavoltage Beams
    Chiu-Tsao, S.
    Chan, M.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [32] Comparison of the radio chromatic EBT film Dosimetry with EBT2 (Gafchromic) for IMRT Verification
    Schwedas, M.
    Howitz, S.
    Wiezorek, T.
    Wendt, T. G.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 105 - 105
  • [33] Absorption spectrum of gafchromic® EBT2 film with angular rotation
    Soah Park
    Kwang-Ho Cheong
    Taejin Hwang
    Jai-Woong Yoon
    Taejin Han
    Haeyoung Kim
    Me-Yeon Lee
    KyoungJu Kim
    Hoonsik Bae
    Sei-Kwon Kang
    Seung Jae Oh
    Yong-Min Huh
    Jin-Suck Suh
    [J]. Journal of the Korean Physical Society, 2015, 67 : 52 - 56
  • [34] Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams
    Inoue, T.
    Sugimoto, S.
    Fukata, K.
    Kurokawa, C.
    Ozawa, S.
    Sasai, K.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3735 - 3736
  • [35] Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry
    Smyth, Lloyd
    Alves, Andrew
    Collins, Katherine
    Beveridge, Sabeena
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1095 - 1106
  • [36] A Study of Dose Response Characteristic for Gafchromic EBT2 Film
    Chen, W.
    Di, X.
    Wang, S.
    Wang, B.
    Bai, X.
    Yang, J.
    Guo, B.
    Huang, K.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Investigation of the gafchromic film-EBT2: Features for UVR measurements
    Abukassem, I.
    Bero, M. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 97 : 360 - 365
  • [38] Evaluation of Gafchromic EBT-XD film, with comparison to EBT3 film, and application in high dose radiotherapy verification
    Palmer, Antony L.
    Dimitriadis, Alexis
    Nisbet, Andrew
    Clark, Catharine H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22): : 8741 - 8752
  • [39] Comprehensive evaluation and new recommendations in the use of Gafchromic EBT3 film
    Liu, Kevin
    Jorge, Patrik Goncalves
    Tailor, Ramesh
    Moeckli, Raphael
    Schuler, Emil
    [J]. MEDICAL PHYSICS, 2023, 50 (11) : 7252 - 7262
  • [40] Verification of CyberKnife Dose Distributions with Gafchromic EBT2 Film
    Koksal, Canan
    Akbas, Ugur
    Kesen, Nazmiye Donmez
    Bilge, Hatice
    Kemikler, Gonul
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2018, 33 (04): : 147 - 153