An unshielded radio-frequency atomic magnetometer with sub-femtoTesla sensitivity

被引:36
|
作者
Keder, David A. [1 ]
Prescott, David W. [1 ]
Conovaloff, Adam W. [1 ]
Sauer, Karen L. [1 ]
机构
[1] George Mason Univ, Sch Phys Astron & Computat Sci, Fairfax, VA 22030 USA
来源
AIP ADVANCES | 2014年 / 4卷 / 12期
基金
美国国家科学基金会;
关键词
NUCLEAR-QUADRUPOLE RESONANCE; OPTICAL MAGNETOMETRY; SQUID AMPLIFIER; ENVIRONMENT; MRI;
D O I
10.1063/1.4905449
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We demonstrate a radio-frequency potassium-vapor magnetometer operating with sensitivities of 0.3 fT/root Hz at 0.5 MHz and 0.9 fT/root Hz at 1.31 MHz in the absence of radio-frequency and mu-metal or magnetic shielding. The use of spatially separated magnetometers, two voxels within the same cell, permits for the subtraction of common mode noise and the retention of a gradient signal, as from a local source. At 0.5 MHz the common mode noise was white and measured to be 3.4 fT/root Hz; upon subtraction the noise returned to the values observed when the magnetometer was shielded. At 1.31 MHz, the common mode noise was from a nearby radio station and was reduced by a factor of 33 upon subtraction, limited only by the radio signal picked up by receiver electronics. Potential applications include in-the-field low-field magnetic resonance, such as the use of nuclear quadrupole resonance for the detection of explosives. (C) 2014 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Electromagnetic induction imaging with a scanning radio frequency atomic magnetometer
    Deans, Cameron
    Cohen, Yuval
    Yao, Han
    Maddox, Benjamin
    Vigilante, Antonio
    Renzoni, Ferruccio
    APPLIED PHYSICS LETTERS, 2021, 119 (01)
  • [32] RADIO-FREQUENCY ATOMIC-HYDROGEN BEAM SOURCE
    SLEVIN, J
    STIRLING, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (11): : 1780 - 1782
  • [33] SENSITIVITY OF RADIO-FREQUENCY MEASUREMENTS IN PRESENCE OF OSCILLATOR NOISE
    STRANDBERG, MW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (02): : 307 - +
  • [34] A novel antenna for sub-atmospheric radio-frequency discharge
    Hu, Xinyue
    Chang, Lei
    Yuan, Xiaogang
    Yang, Xin
    Chang, Yunju
    Zhang, Lupeng
    Zhou, Haishan
    Luo, Guangnan
    Dai, Jia
    Liu, Jia
    Hang, Guanrong
    CONTRIBUTIONS TO PLASMA PHYSICS, 2020, 60 (04)
  • [36] Quantum Measurement of Radio-Frequency Attenuation Based on Atomic Resonance
    Yamamoto, Masahiro J. J.
    Tojima, Yuya
    Kinoshita, Moto
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [37] Inductive Imaging of the Concealed Defects with Radio-Frequency Atomic Magnetometers
    Bevington, P.
    Gartman, R.
    Chalupczak, W.
    APPLIED SCIENCES-BASEL, 2020, 10 (19): : 1 - 14
  • [38] RADIO-FREQUENCY GLOW DISCHARGE ATOMIC EMISSION AND MASS SPECTROMETRY
    Kawaguchi, Hiroshi
    Tanaka, Tomokazu
    Fukaya, Hiroyasu
    ANALYTICAL SCIENCES, 1991, 7 : 537 - 540
  • [39] Magic radio-frequency dressing for trapped atomic microwave clocks
    Kazakov, G. A.
    Schumm, T.
    PHYSICAL REVIEW A, 2015, 91 (02):
  • [40] Optimized detection modality for radio-frequency sensing with a double-resonance alignment magnetometer
    Akbar, A.
    Koźbial, M.
    Elson, L.
    Meraki, A.
    Kolodyński, J.
    Jensen, K.
    Physical Review Applied, 22 (05):