Improved performance of N-(Hydroxymethyl)acrylamide gel dosimeter using potassium chloride for radiotherapy

被引:17
|
作者
Rabaeh, Khalid A. [1 ]
Hammoudeh, Issra' M. E. [2 ]
Eyadeh, Molham M. [3 ]
Aldweri, Feras M. [4 ]
Awad, Samer, I [5 ]
Oglat, Ammar A. [1 ]
Shatnawi, Moneeb T. M. [2 ]
机构
[1] Hashemite Univ, Fac Appl Med Sci, Med Imaging Dept, Zarqa 13133, Jordan
[2] Univ Jordan, Sch Sci, Phys Dept, Amman 11942, Jordan
[3] Yarmouk Univ, Fac Sci, Phys Dept, Irbid 21163, Jordan
[4] Hashemite Univ, Fac Sci, Phys Dept, Zarqa 13133, Jordan
[5] Hashemite Univ, Fac Engn, Biomed Engn Dept, Zarqa 13133, Jordan
关键词
Dosimeter; N-(Hydroxymethyl)acrylamide; Potassium chloride; Gel; Radiotherapy;
D O I
10.1016/j.radmeas.2021.106542
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this study, polymer-gel dosimeters containing N-(Hydroxymethyl) acrylamide (NHMA) with different concentrations of potassium chloride (KCl) were developed and introduced for use in radiotherapy. The gels were irradiated with a megavolt X-ray photon beam up to 10 Gy using a medical linear accelerator. The irradiated NHMA_KCl dosimeters were evaluated by nuclear magnetic resonance (NMR), in terms of relaxation rate (R2). The results show that the dose sensitivity of polymer gel was improved by 33% when KCl concentration was increased from 0 to 1.9 wt%. The decrease in R2 values with increasing scanning temperature was 1.6% per ?C at 6 Gy. The dosimeter was found stable within a period of 2?120 h after irradiation and is independent of dose-rate in the range of 50?600 cGy/min and independent of photon beam energy between 6 and 15 MV within 7.5% overall uncertainty.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] RADIATION GRAFTING OF N-(HYDROXYMETHYL)-ACRYLAMIDE IN THE SOLID-STATE ONTO LINEN FABRICS
    ROSIAK, J
    PEKALA, W
    NUKLEONIKA, 1981, 26 (7-8) : 849 - 854
  • [22] N-(hydroxymethyl) acrylamide as a multifunctional finish to cotton and a tether for grafting methacrylamide for biocidal coatings
    Yildiz, Ozkan
    Cerkez, Idris
    Kocer, Hasan B.
    Worley, S. D.
    Broughton, R. M.
    Huang, T. S.
    JOURNAL OF APPLIED POLYMER SCIENCE, 2013, 128 (06) : 4405 - 4410
  • [23] High dose sensitivity of N-(isobutoxymethyl)acrylamide polymer gel dosimeters with improved monomer solubility using acetone co-solvent
    Rabaeh, Khalid A.
    Al-Ajaleen, Musab S.
    Abuzayed, Manar H.
    Aldweri, Feras M.
    Eyadeh, Molham M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 442 : 67 - 72
  • [24] A study of a normoxic polymer gel dosimeter comprising methacrylic acid, gelatin and tetrakis (hydroxymethyl) phosphonium chloride (MAGAT)
    Hurley, C
    Venning, A
    Baldock, C
    APPLIED RADIATION AND ISOTOPES, 2005, 63 (04) : 443 - 456
  • [25] Improved functionality of antibody-colloidal gold conjugates with the aid of lipoamide-grafted N-[tris(hydroxymethyl)methyl]acrylamide polymers
    Albers, Willem M.
    Munter, Tony
    Laaksonen, Paivi
    Vikholm-Lundin, Inger
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2010, 348 (01) : 1 - 8
  • [26] Dose distribution verification in intraoperative radiation therapy using an N-isopropyl acrylamide-based polymer gel dosimeter
    Seyed Mohammad Mahdi Abtahi
    Roghayeh Kargar Shaker Langaroodi
    Mohammad Esmail Akbari
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 324 : 481 - 488
  • [27] Dose distribution verification in intraoperative radiation therapy using an N-isopropyl acrylamide-based polymer gel dosimeter
    Abtahi, Seyed Mohammad Mahdi
    Langaroodi, Roghayeh Kargar Shaker
    Akbari, Mohammad Esmail
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 324 (02) : 481 - 488
  • [28] Enthalpic Interaction Coefficients of N-(N- Glycylglycyl)glycine in Aqueous Sodium Chloride and Potassium Chloride Solutions at 298.15 K
    Liu, Min
    Wang, Lili
    Li, Guangqian
    Sun, Dezhi
    Zhu, Lanying
    Di, Youying
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2010, 55 (05): : 1842 - 1846
  • [29] Dosimetric Evaluation of Tissue Equivalent Gel Dosimeter Using Saccharide in Radiotherapy System
    Cho, Y.
    Lee, D.
    Jung, H.
    Ji, Y.
    Kim, K.
    Chang, U.
    Kwon, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 252 - 252
  • [30] PREPARATION OF N-(1,1-DIMETHYL-3-TRIMETHYLAMMONIOPROPYL)-ACRYLAMIDE CHLORIDE
    SHIRSHIN, KV
    KAZANTSEV, OA
    ZILBERMAN, EN
    SALOV, VN
    MOLOTKOV, VA
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1990, 63 (12): : 2579 - 2581