Hyperpolarized 3He MR for Sensitive Imaging of Ventilation Function and Treatment Efficiency in Young Cystic Fibrosis Patients with Normal Lung Function

被引:66
|
作者
Bannier, Elise [1 ]
Cieslar, Katarzyna [1 ]
Mosbah, Karim [1 ]
Aubert, Francoise [2 ]
Duboeuf, Francois [1 ]
Salhi, Zahir [3 ]
Gaillard, Sophie [1 ]
Berthezene, Yves [1 ]
Cremillieux, Yannick [1 ]
Reix, Philippe [4 ]
机构
[1] Univ Lyon, CNRS, INSERM, CREATIS,UMR 5220,U630,LRMN, F-69622 Villeurbanne, France
[2] Ctr Invest Clin, Lyon, France
[3] Johannes Gutenberg Univ Mainz, Mainz, Germany
[4] Hop Femme Mere Enfant, Serv Pediat, Lyon, France
关键词
COMPUTED-TOMOGRAPHY; AIR SPACES; CHILDREN; SPIROMETRY; DISEASE; GAS;
D O I
10.1148/radiol.09090039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the sensitivity of hyperpolarized helium 3 (He-3) magnetic resonance (MR) imaging for the detection of peripheral airway obstruction in younger cystic fibrosis (CF) patients showing normal spirometric results (mean forced expiratory volume in 1 second [FEV1], 112% +/- 14.5 [standard deviation]) and to observe the immediate effects of a single chest physical therapy (CPT) session, thereby comparing two image quantification techniques. Materials and Methods: Ten pediatric CF patients (age range, 8-16 years) with normal spirometric results were included in this study after approval from the local research ethics committee. Spirometry followed by proton and hyperpolarized 3 He three-dimensional lung imaging were performed with a 1.5-T MR unit before and after 20 minutes of CPT. The number of ventilation defects per image (VDI) and the ventilated lung fraction (VF), defined as the ratio of ventilated lung volume divided by total lung volume, were quantified. Results: Ventilation defects were found in all patients (mean VDI, 5.1 +/- 1.9; mean global VF, 78.5% +/- 12.3; and mean peripheral VF, 75.5% +/- 17.1) despite normal spirometric results. After CPT, disparate changes in the distribution of ventilation defects were observed but the average VDI and VF did not change significantly (mean VDI, 5.1 +/- 1.1; mean global VF, 83.5% +/- 12.2; and mean peripheral VF, 80.3% +/- 12.2). There was no correlation between FEV1 and VDI (rho = -0.041, P = .863) or global VF (rho = -0.196, P = .408) values but peripheral VF and VDI were correlated (rho = -0.563, P = .011). Conclusion: Although spirometric results indicate normal lung function, the mean VDI in patients (5.1) found in this study is well above the VDI in healthy subjects (1.6) reported in the literature. A single CPT session induces disparate changes in the distribution and extent of ventilation defects. (C) RSNA, 2010
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [41] Short- and Long-Term Lung Function Variability in COPDs Using Hyperpolarized 3He MRI
    Hamedani, H.
    Baron, R.
    Kadlecek, S.
    Ruppert, K.
    Siddiqui, S.
    Spencer, M.
    Xin, Y.
    Duncan, I.
    Cereda, M.
    Amzajerdian, F.
    Loza, L.
    Pourfathi, M.
    Diamond, J. M.
    Rossman, M. D.
    Rizi, R. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [42] Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan
    Miller, GW
    Altes, TA
    Brookeman, JR
    de Lange, EE
    Mugler, JP
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 16 (05) : 218 - 226
  • [43] Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan
    G. W. Miller
    T. A. Altes
    J. R. Brookeman
    E. E. de Lange
    J. P. Mugler III
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 16 : 218 - 226
  • [44] Reduced exercise ventilatory efficiency in adults with cystic fibrosis and normal to moderately impaired lung function
    Di Paolo, Marcello
    Teopompi, Elisabetta
    Savi, Daniela
    Crisafulli, Ernesto
    Longo, Chiara
    Tzani, Panagiota
    Longo, Francesco
    Ielpo, Antonella
    Pisi, Giovanna
    Cimino, Giuseppe
    Simmonds, Nicholas J.
    Neder, J. Alberto
    Chetta, Alfredo
    Palange, Paolo
    JOURNAL OF APPLIED PHYSIOLOGY, 2019, 127 (02) : 501 - 512
  • [45] Hyperpolarized 3He and 129Xe MR Imaging in Healthy Volunteers and Patients with Chronic Obstructive Pulmonary Disease
    Kirby, Miranda
    Svenningsen, Sarah
    Owrangi, Amir
    Wheatley, Andrew
    Farag, Adam
    Ouriadov, Alexei
    Santyr, Giles E.
    Etemad-Rezai, Roya
    Coxson, Harvey O.
    McCormack, David G.
    Parraga, Grace
    RADIOLOGY, 2012, 265 (02) : 600 - 610
  • [46] Risk factors for lung function decline in a large cohort of young cystic fibrosis patients
    Cogen, Jonathan
    Emerson, Julia
    Sanders, Don B.
    Ren, Clement
    Schechter, Michael S.
    Gibson, Ronald L.
    Morgan, Wayne
    Rosenfeld, Margaret
    PEDIATRIC PULMONOLOGY, 2015, 50 (08) : 763 - 770
  • [47] Hyperpolarized 3helium magnetic resonance ventilation imaging of the lung in cystic fibrosis:: comparison with high resolution CT and spirometry
    McMahon, Colm J.
    Dodd, Jonathan D.
    Hill, Catherine
    Woodhouse, Neil
    Wild, Jim M.
    Fichele, Stan
    Gallagher, Charles G.
    Skehan, Stephen J.
    van Beek, Edwin J. R.
    Masterson, James B.
    EUROPEAN RADIOLOGY, 2006, 16 (11) : 2483 - 2490
  • [48] Hyperpolarized 3helium magnetic resonance ventilation imaging of the lung in cystic fibrosis: comparison with high resolution CT and spirometry
    Colm J. McMahon
    Jonathan D. Dodd
    Catherine Hill
    Neil Woodhouse
    Jim M. Wild
    Stan Fichele
    Charles G. Gallagher
    Stephen J. Skehan
    Edwin J. R. van Beek
    James B. Masterson
    European Radiology, 2006, 16 : 2483 - 2490
  • [49] Progression of Emphysema Evaluated by MRI Using Hyperpolarized 3He (Hp 3He) Measurements in Patients with Alpha-1-Antitrypsin (A1AT) Deficiency Compared with CT and Lung Function Tests
    Stavngaard, T.
    Sogaard, L. Vejby
    Batz, M.
    Schreiber, L. M.
    Dirksen, A.
    ACTA RADIOLOGICA, 2009, 50 (09) : 1019 - 1026
  • [50] Three-dimensional Isotropic Functional Imaging of Cystic Fibrosis Using Oxygen-enhanced MRI: Comparison with Hyperpolarized 3He MRI
    Zha, Wei
    Nagle, Scott K.
    Cadman, Robert V.
    Schiebler, Mark L.
    Fain, Sean B.
    RADIOLOGY, 2019, 290 (01) : 229 - 237