Wavelength Dependence of Ultrahigh-Resolution Optical Coherence Tomography Using Supercontinuum for Biomedical Imaging

被引:41
|
作者
Nishizawa, Norihiko [1 ]
Kawagoe, Hiroyuki [1 ]
Yamanaka, Masahito [1 ]
Matsushima, Miyoko [2 ]
Mori, Kensaku [3 ]
Kawabe, Tsutomu [2 ]
机构
[1] Nagoya Univ, Dept Elect Engn & Comp Sci, Nagoya, Aichi 4648603, Japan
[2] Nagoya Univ, Grad Sch Med, Nagoya, Aichi 4668550, Japan
[3] Nagoya Univ, Grad Sch Informat, Nagoya, Aichi 4648601, Japan
基金
日本学术振兴会;
关键词
Optical coherence tomography; supercontinuum; optical coherence microscopy; fiber lasers; ultrashort pulse; 1.7; MU-M; ALL-FIBER SYSTEM; REAL-TIME; BRONCHIAL LESIONS; WATER-CONTENT; LIGHT-SOURCE; LOW-NOISE; EX-VIVO; GENERATION; MICROSCOPY;
D O I
10.1109/JSTQE.2018.2854595
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical coherence tomography (OCT) is a noninvasive cross-sectional imaging technique with micrometer resolution. The theoretical axial resolution is determined by the center wavelength and bandwidth of the light source, and the wider the bandwidth, the higher the axial resolution. The characteristics of OCT imaging depend on the optical wavelength used. In this paper, we investigated the wavelength dependence of ultrahigh-resolution (UHR) OCT using a supercontinuum for biomedical imaging. Wideband, high-power, low-noise supercontinua (SC) were generated at lambda = 0.8,1.1,1.3, and 1.7 mu m based on ultrashort pulses and nonlinear fibers. The wavelength dependence of OCT imaging was examined quantitatively using biological phantoms. Ultra high-resolution imaging of a rat lung was demonstrated with lambda = 0.8-1.0 mu m UHR-OCT. The variation of alveolar volume was estimated using three-dimensional image analysis. Finally, UHR-spectral domain-OCT and optical coherence microscopy at 1.7 mu m were developed, and high-resolution and high-penetration imaging of turbid tissue, especially mouse brain, was demonstrated.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Myocardial imaging using ultrahigh-resolution spectral domain optical coherence tomography
    Yao, Xinwen
    Gan, Yu
    Marboe, Charles C.
    Hendon, Christine P.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [12] In vivo ultrahigh-resolution optical coherence tomography
    Drexler, W
    Morgner, U
    Kärtner, FX
    Pitris, C
    Boppart, SA
    Li, XD
    Ippen, EP
    Fujimoto, JG
    OPTICS LETTERS, 1999, 24 (17) : 1221 - 1223
  • [13] Ultrahigh-resolution optical coherence tomography in glaucoma
    Wollstein, G
    Paunescu, LA
    Ko, TH
    Fujimoto, JG
    Kowalevicz, A
    Hartl, I
    Beaton, S
    Ishikawa, H
    Mattox, C
    Singh, O
    Duker, J
    Drexler, W
    Schuman, JS
    OPHTHALMOLOGY, 2005, 112 (02) : 229 - 237
  • [14] Ultrahigh-resolution ophthalmic optical coherence tomography
    Drexler, W
    Morgner, U
    Ghanta, RK
    Kärtner, FX
    Schuman, JS
    Fujimoto, JG
    NATURE MEDICINE, 2001, 7 (04) : 502 - 507
  • [15] Ultrahigh-resolution ophthalmic optical coherence tomography
    Wolfgang Drexler
    Uwe Morgner
    Ravi K. Ghanta
    Franz X. Kärtner
    Joel S. Schuman
    James G. Fujimoto
    Nature Medicine, 2001, 7 : 502 - 507
  • [16] Retinal oximetry using ultrahigh-resolution optical coherence tomography
    Ye, Yufeng
    Jiang, Hong
    Shen, Meixiao
    Lam, Byron L.
    DeBuc, Delia Cabrera
    Ge, Lili
    Sehi, Mitra
    Wang, Jianhua
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 2085 - 2092
  • [17] Supercontinuum generation for ultrahigh-resolution optical coherence tomography at wavelength of 0.8 μm using carbon nanotube fiber laser and similariton amplifier
    Nomura, Yoshitaka
    Kawagoe, Hiroyuki
    Hattori, Yuji
    Yamanaka, Masahito
    Omoda, Emiko
    Kataura, Hiromichi
    Sakakibara, Youichi
    Nishizawa, Norihiko
    APPLIED PHYSICS EXPRESS, 2014, 7 (12)
  • [18] Optical clearing for luminal organ imaging with ultrahigh-resolution optical coherence tomography
    Liang, Yanmei
    Yuan, Wu
    Mavadia-Shukla, Jessica
    Lia, Xingde
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (08)
  • [19] Ultrahigh-resolution optical coherence tomography at 1.3 μm central wavelength by using a supercontinuum source pumped by noise-like pulses
    You, Yi-Jing
    Wang, Chengming
    Lin, Yi-Lun
    Zaytsev, Alexey
    Xue, Ping
    Pan, Ci-Ling
    LASER PHYSICS LETTERS, 2016, 13 (02)
  • [20] Imaging Retinal Capillaries Using Ultrahigh-Resolution Optical Coherence Tomography and Adaptive Optics
    Wang, Qiang
    Kocaoglu, Omer P.
    Cense, Barry
    Bruestle, Jeremy
    Jonnal, Ravi S.
    Gao, Weihua
    Miller, Donald T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (09) : 6292 - 6299