Is low ejection fraction safe for off-pump coronary bypass operation?

被引:83
|
作者
Arom, KV [1 ]
Flavin, TF [1 ]
Emery, RW [1 ]
Kshettry, VR [1 ]
Petersen, RJ [1 ]
Janey, PA [1 ]
机构
[1] Cardiac Surg Associates PA, Minneapolis, MN 55407 USA
来源
ANNALS OF THORACIC SURGERY | 2000年 / 70卷 / 03期
关键词
D O I
10.1016/S0003-4975(00)01761-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Does the manipulation of the heart during off-pump coronary artery bypass (OPCAB) procedure further compromise the hemodynamic stability of a patient with depressed left ventricular function compared with the conventional coronary artery bypass (CCAB) approach? Does this manipulation induce a more dramatic hypoperfused state that may contribute to an increase in the incidence of related complications or mortality? This retrospective review of data attempted to answer the above concern. Methods. Between January 1, 1998, and June 30, 1999, 177 patients with ejection fractions of 30% or less underwent full sternotomy coronary artery bypass grafting at our institution. Of these patients, 45 underwent OPCAB procedures and 132 patients underwent CCAB. Pre-, intra-, and postoperative variables as identified by The Society of Thoracic Surgeons National Cardiac Surgery Database were compared using univariate and logistical regression analysis. Results. Despite recognized hemodynamic derangement during cardiac displacement, these groups of OPCAB patients appeared to tolerate the procedure well. Univariate analysis of cardiac enzyme leak and blood loss was statistically significant in the OPCAB patients. Utilizing regression analysis, cardiopulmonary bypass was the only predictor for all postoperative complications. Conclusions. Multivessel coronary artery bypass utilizing the OPCAB approach in patients with depressed left ventricular function of equal to or less than 30% is appropriate and applicable. Analysis of CCAB and OPCAB variables was nonsignificant except for operative and postoperative blood loss and peak cardiac enzyme leak. Attention to intraoperative detail and hemodynamic management could be credited for the success with OPCAB. (Ann Thorac Surg 2000;70:1021-5) (C) 2000 by The Society of Thoracic Surgeons.
引用
收藏
页码:1021 / 1025
页数:5
相关论文
共 50 条
  • [11] Off-pump coronary bypass surgery
    Healey, J
    Fenwick, E
    O'Brien, B
    NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (19): : 1929 - 1930
  • [12] Aspirin efficacy is reduced following off-pump coronary bypass operation
    Wurtz, M.
    Modrau, I. S.
    Kristensen, S. D.
    Hvas, A. M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 761 - 762
  • [13] ICU Stay in Patients with Low Ejection Fraction Undergoing Cardiac Revascularization: Comparison of On-Pump Versus Off-Pump Coronary Artery Bypass Grafting
    Bilal, Muhammad
    Fawad, Ahmad
    Shah, Syed Mumtaz Anwar
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (08): : 2494 - 2496
  • [14] On-pump and off-pump coronary bypass surgery
    Lytle, Bruce W.
    CIRCULATION, 2007, 116 (10) : 1108 - 1109
  • [15] Safe coronary artery occlusion with a new tourniquet in off-pump bypass grafting
    Arai, H
    Oi, K
    Tanaka, H
    Tabuchi, N
    Sunamori, M
    ANNALS OF THORACIC SURGERY, 2005, 80 (03): : 1137 - 1139
  • [16] Off-pump bypass grafting is safe in patients with left main coronary disease
    Dewey, TM
    Magee, MJ
    Edgerton, JR
    Mathison, M
    Tennison, D
    Mack, MJ
    ANNALS OF THORACIC SURGERY, 2001, 72 (03): : 788 - 791
  • [17] Myocardial injury after off-pump coronary artery bypass grafting operation
    Paparella, Domenico
    Cappabianca, Giangiuseppe
    Malvindi, Piergiorgio
    Paramythiotis, Andreas
    Galeone, Antonella
    Veneziani, Nicola
    Fondacone, Corrado
    Schinosa, Luigi de Luca Tupputi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 32 (03) : 481 - 487
  • [18] Antithrombotic Controversies in Off-Pump Coronary Bypass
    Karmanoukian, Hratch
    Attuwabi, Bashir
    Nader, Nader D.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2005, 17 (01) : 59 - 65
  • [19] Magnesium and off-pump coronary artery bypass
    Huss, MG
    Wasnick, JD
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (03) : 374 - 375
  • [20] Off-pump reoperative coronary artery bypass
    R Mehrotra
    P K Rath
    S Vanzara
    U Patil
    S Vaishnav
    N Garach
    R Panda
    Indian Journal of Thoracic and Cardiovascular Surgery, 2004, 20 (1) : 6 - 6