Performance Evaluation of the New Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Test Version 2.0 for Quantification of Human Immunodeficiency Virus Type 1 RNA

被引:52
|
作者
Pas, Suzan [1 ]
Rossen, John W. A. [2 ]
Schoener, Daniel [3 ]
Thamke, Diana [3 ]
Pettersson, Annika [4 ]
Babiel, Reiner [3 ]
Schutten, Martin [1 ]
机构
[1] Erasmus MC, Dept Virol, NL-3015 CE Rotterdam, Netherlands
[2] St Elizabeth Hosp, Lab Med Microbiol & Immunol, Tilburg, Netherlands
[3] Roche Mol Diagnost, Rotkreuz, Switzerland
[4] Vrije Univ Amsterdam Med Ctr, Dept Med Microbiol & Infect Control, Amsterdam, Netherlands
关键词
ACID-BASED TECHNIQUES; QUANTITATIVE DETECTION; MONITOR VERSION-1.5; AMPLICOR MONITOR; HUMAN PLASMA; VIRAL LOAD; AMPLIFICATION; ASSAY; PCR; INFECTION;
D O I
10.1128/JCM.01832-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Despite FDA approval and CE marking of commercial tests, manufacturer-independent testing of the technical aspects of newly developed tests is important. To evaluate the analytical performance and explore the clinical applicability of the new Roche COBAS AmpliPrep COBAS TaqMan HIV-1 test, version 2.0 (CAP/CTM v2.0), platform comparison was performed with the Roche CAP/CTM test, version 2.0, the COBAS Amplicor HIV-1 Monitor Test, version 1.5 (CAP/CA v1.5), the COBAS AmpliPrep COBAS TaqMan HIV-1 Test (CAP/CTM v1.0), and the Abbott m2000 RealTime HIV-1 assay on panels and diagnostic samples. Specificity was tested for HIV-2 samples. Furthermore, samples from HIV-1-seropositive individuals with CAP/CA v1.5-measured viral loads below 50 HIV-1 RNA copies per ml (cp/ml) and replicates of HIV-1-seronegative plasma were tested in a checkerboard analysis. CAP/CTM v2.0 is HIV-1 specific, with broad genotype inclusivity and no serious underquantification of viral load relative to the other assays used. Low viral loads below the threshold of quantification for CAP/CA v1.5 are observed with CAP/CTM v2.0. A CAP/CTM v2.0-measured viral load of >50 copies/ml in these samples correlated with therapy failure. In conclusion, CAP/CTM v2.0 is an accurate and reliable test for HIV-1 viral load measurement relative to the other assays used with respect to specificity, sensitivity, and genotype inclusivity.
引用
收藏
页码:1195 / 1200
页数:6
相关论文
共 50 条
  • [21] Comparison of Abbott RealTime HIV-1 and Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Assays
    Abravaya, K.
    Hackett, J.
    Swanson, P.
    Huang, S.
    Tang, N.
    Robinson, J.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [22] Comparison of the QIAGEN artus HIV-1 QS-RGQ test with the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v2.0
    Wall, G. R.
    Perinpanathan, D.
    Clark, D. A.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2012, 55 (01) : 62 - 66
  • [23] Comparison of the Roche COBAS Amplicor™ monitor, Roche COBAS Ampliprep™/COBAS Taqman™ and Abbott RealTime™ test assays for quantification of hepatitis c virus and HIV RNA
    Wolff, Dietmar
    Gerritzen, Andreas
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (07) : 917 - 922
  • [24] Comparison of the Hologic Aptima HIV-1 Quant Dx assay to the Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Test v2.0 for the quantification of HIV-RNA in plasma samples
    Schonning, K.
    Johansen, K.
    Landt, B.
    Benfield, T.
    Westh, H.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S53 - S53
  • [25] Total HIV-1 DNA detection and quantification in peripheral blood by COBAS®AmpliPrep/COBAS® TaqMan® HIV-1 Test, v2.0
    Surdo, Matteo
    Bertoli, Ada
    Colucci, Giuseppe
    Sarmati, Loredana
    Andreoni, Massimo
    Perno, Carlo Federico
    Ceccherini-Silberstein, Francesca
    Ciotti, Marco
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (02) : E57 - E59
  • [26] Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
    Sloma, Cari R.
    Germer, Jeffrey J.
    Gerads, Tara M.
    Mandrekar, Jayawant N.
    Mitchell, P. Shawn
    Yao, Joseph D. C.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (04) : 889 - 895
  • [27] Improved Performance of COBAS AmpliPrep/COBAS TaqMan Version 2.0 Assay Over Amplicor Monitor Version 1.5 in the Quantification of HIV-1 RNA Viral Load in Abuja, Nigeria
    Abubakar, Ado
    Ndembi, Nicaise
    Ogbanufe, Obinna
    Inalegwu, Auchi
    Wilson, Simi
    Ebagua, Irene
    Peters, Sam
    Chime, Chris
    Dakum, Patrick
    Abimiku, Alash'le G.
    [J]. CURRENT HIV RESEARCH, 2015, 13 (04) : 262 - 267
  • [28] Cost Ramifications of Increased Reporting of Detectable Plasma HIV-1 RNA Levels by the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Version 1.0 Viral Load Test
    Willig, James H.
    Nevin, Christa R.
    Raper, James L.
    Saag, Michael S.
    Mugavero, Michael J.
    Willig, Amanda L.
    Burkhardt, Jeffrey H.
    Schumacher, Joseph E.
    Johnson, Victoria A.
    [J]. JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2010, 54 (04) : 442 - 444
  • [29] Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China
    Xu, Sihong
    Song, Aijing
    Nie, Jianhui
    Li, Xiuhua
    Meng, Shufang
    Zhang, Chuntao
    Wang, Youchun
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (01) : 33 - 37
  • [30] COMPARISON OF THE APTIMA HIV-1 QUANT ASSAY TO THE COBAS AMPLIPREP/COBAS TAQMAN HIV-1 TEST, V2.0
    Hatzakis, A.
    Papachristou, H.
    Kantzanou, M.
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 : A353 - A353