Final results from the SRC plane grating monochromator

被引:0
|
作者
Severson, M [1 ]
Bissen, M [1 ]
Fisher, M [1 ]
Kubala, T [1 ]
Rogers, G [1 ]
Reininger, R [1 ]
机构
[1] Univ Wisconsin, Ctr Synchrotron Radiat, Stoughton, WI 53589 USA
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high resolution, high throughput plane grating monochromator (PGM) has been completed and is now in use by experimentalists at the Synchrotron Radiation Center (SRC). The initial characterization of the beamline was performed using a flawed grating. The original grating has been replaced with a new laminar profile 1200 l/mm grating. A resolving power of 36000 at 21.6 eV with no significant beamline aperturing was achieved. This agrees well with the expected value and surpasses the best measurements made with the first grating. Experimentalists are also enjoying high throughput levels due to a factor of nearly four increase in the first order grating efficiency. A permanent magnet undulator continues to provide a stable source for the beamline and users can now scan the beamline and undulator together from 21 to 245 eV at a ring energy of 800 MeV with no limitations.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 50 条
  • [21] Plane-grating monochromator at BESSY II using collimated light
    Follath, R
    Senf, F
    Gudat, W
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 769 - 771
  • [22] First results of SRC's new high-energy resolution variable line density grating monochromator beamline: HERMON
    Univ of Wisconsin-Madison, Stoughton, United States
    Rev Sci Instrum, 2 pt 2 (2072-2074):
  • [23] Control of spectral aberrations in a monochromator using a plane holographic chirped grating
    April, Alexandre
    McCarthy, Nathalie
    APPLIED OPTICS, 2008, 47 (15) : 2750 - 2759
  • [24] Adaptation of UVSOR-Type Plane-Grating Monochromator in Saga
    Sugiyama, H.
    Takahashi, K.
    Ogawa, K.
    Azuma, J.
    Kamada, M.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 685 - 688
  • [25] Plane-grating monochromator beamline for the PTB undulators at BESSY II
    Senf, F
    Flechsig, U
    Eggenstein, F
    Gudat, W
    Klein, R
    Rabus, H
    Ulm, G
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 780 - 782
  • [26] THERMAL EFFECTS OF UNDULATOR RADIATION ON SI OPTICS FOR A PLANE GRATING MONOCHROMATOR
    JENSEN, BN
    MANCINI, DC
    NYHOLM, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 2129 - 2131
  • [27] A plane-grating monochromator for circularly polarized undulator radiation at BESSY II
    Senf, F
    Sawhney, KJS
    Follath, R
    Scheer, M
    Schafers, F
    Bahrdt, J
    Gaupp, A
    Gudat, W
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 747 - 749
  • [28] A plane-grating monochromator for circularly polarized undulator radiation at BESSY II
    Senf, F.
    Sawhney, K.J.S.
    Follath, R.
    Scheer, M.
    Schafers, F.
    Bahrdt, J.
    Gaupp, A.
    Gudat, W.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 747 - 749
  • [29] NEW GRATING MONOCHROMATOR
    NAMIOKA, T
    SPECTROCHIMICA ACTA, 1956, 8 (4-5): : 308 - 309
  • [30] HIGHER-ORDER SUPPRESSION IN AN ON-BLAZE PLANE-GRATING MONOCHROMATOR
    HUNTER, WR
    RIFE, JC
    APPLIED OPTICS, 1984, 23 (02): : 293 - 299