Influence of alcohol addition on gas hold-up in bubble columns: Development of a scale up model

被引:33
|
作者
Krishna, R [1 ]
Dreher, AJ [1 ]
Urseanu, MI [1 ]
机构
[1] Univ Amsterdam, Dept Chem Engn, NL-1018 WV Amsterdam, Netherlands
关键词
D O I
10.1016/S0735-1933(00)00129-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
Measurements were carried out in bubble columns with diameters of 0.1, 0.15 and 0.38 m with air - water system to which ethanol was added in concentrations ranging from 0.03 - 1 volume %. Alcohol addition results in a significant increase in the gas hold-up, epsilon. This increase in epsilon can be attributed to a delay in the point of transition from homogeneous to heterogeneous flow regime. The model of Krishna et al. (Chem. Eng. Sci., 54, 171 (1999)) was found applicable for the range of column diameters studied, after accounting for the influence of alcohol addition on the regime transition parameters. (C) 2000 Elsevier Science Ltd.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 50 条
  • [31] Gamma ray tomography - An experimental analysis of fractional gas hold-up in bubble columns
    Patel, Ashutosh K.
    Thorat, Bhaskar N.
    CHEMICAL ENGINEERING JOURNAL, 2008, 137 (02) : 376 - 385
  • [32] GAS HOLD-UP AND MASS-TRANSFER CHARACTERISTICS OF PACKED BUBBLE-COLUMNS
    SAWANT, SB
    PANGARKAR, VG
    JOSHI, JB
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1979, 18 (02): : 143 - 149
  • [33] Measurement of gas hold-up in bubble columns from low frequency acoustic emissions
    Boyd, JWR
    Varley, J
    CHEMICAL ENGINEERING JOURNAL, 2002, 88 (1-3) : 111 - 118
  • [34] MIXING CHARACTERISTICS AND GAS HOLD-UP OF A BUBBLE COLUMN
    GUY, C
    CARREAU, PJ
    PARIS, J
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1986, 64 (01): : 23 - 35
  • [35] VARIATION OF GAS HOLD-UP IN BUBBLE COLUMNS WITH PHYSICAL PROPERTIES OF LIQUIDS AND OPERATING PARAMETERS OF COLUMNS.
    Bach, Hans F.
    Pilhofer, Theo
    1978, 1 (05): : 270 - 275
  • [36] Gas hold-up and solids hold-up in flotation columns: On-line measurement based on electrical conductivity
    Tavera, F.J.
    Escudero, R.
    Transactions of the Institutions of Mining and Metallurgy, Section C: Mineral Processing and Extractive Metallurgy, 2002, 111 (MAY/AUG):
  • [37] Gas hold-up and solids hold-up in flotation columns: on-line measurement based on electrical conductivity
    Tavera, FJ
    Escudero, R
    TRANSACTIONS OF THE INSTITUTIONS OF MINING AND METALLURGY SECTION C-MINERAL PROCESSING AND EXTRACTIVE METALLURGY, 2002, 111 : C94 - C99
  • [38] Gas hold-up, liquid circulation and gas-liquid mass transfer in slurry bubble columns
    Gavroy, D.
    Joly-Vuillemin, C.
    Cordier, G.
    Delmas, H.
    Chemical Engineering Research and Design, 1995, 73 (A6) : 637 - 642
  • [39] Effect of sparger design and height to diameter ratio on fractional gas hold-up in bubble columns
    Thorat, BN
    Shevade, AV
    Bhilegaonkar, KN
    Aglawe, RH
    Veera, UP
    Thakre, SS
    Pandit, AB
    Sawant, SB
    Joshi, JB
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A7): : 823 - 834
  • [40] LIQUID CIRCULATION PATTERNS AND THEIR EFFECT ON GAS HOLD-UP AND AXIAL MIXING IN BUBBLE-COLUMNS
    WALTER, JF
    BLANCH, HW
    CHEMICAL ENGINEERING COMMUNICATIONS, 1983, 19 (4-6) : 243 - 262