共 50 条
Adsorptive stripping determination of trifluralin on a glassy carbon electrode
被引:9
|作者:
Radi, AE
[1
]
机构:
[1] Univ Mansoura, Fac Sci, Dept Chem, Demiatta 34517, Egypt
关键词:
trifluralin;
cyclic voltammetry;
adsorptive voltammetry;
D O I:
10.1080/03067310008034118
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The herbicide trifluralin was analysed by adsorptive stripping voltammetry on a glassy carbon electrode. The linear concentration range was 2.5 x 10(-7) M - 1.25 x 10(-6)M when using 5-min preconcentration at open circuit conditions in Britton-Robinson buffer of pH 7.0. The detection limit of trifluralin was 2.5 x 10(-8)M. The relative standard deviation was 3.3 % at a concentration of 1.0 x 10(-6)M (n=5), The method was applied to the determination of trifluralin in soil with good recovery.
引用
收藏
页码:61 / 68
页数:8
相关论文