Usability evaluation of a novel compact pneumatic compression device for the treatment of lymphoedema: Pilot study

被引:0
|
作者
Devitt, Martin [1 ]
Ramanan, Dinesh [2 ]
Armitstead, Jeff [3 ]
Zhu, Xueling [3 ]
Mackie, Helen [4 ,5 ]
机构
[1] Lifecycle Med, POB 500, Newport, NSW 2106, Australia
[2] Aria Hlth, San Diego, CA USA
[3] ResMed Sci Ctr, Sydney, NSW, Australia
[4] Alert Macquarie Univ, Sydney, NSW, Australia
[5] Mt Wilga Private Hosp, Hornsby, NSW, Australia
关键词
intermittent pneumatic compression; lymphoedema; lifestyle; patient satisfaction; sequential compression device; BREAST-CANCER; LIMB VOLUME; THERAPY; MANAGEMENT; SECONDARY; PRESSURE; BENEFITS; WOMEN;
D O I
10.1177/02683555221096298
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To perform a preliminary usability evaluation of a novel, compact pneumatic compression device in patients with lymphoedema. Methods: This open-label, single-arm trial had two phases: the first focused on the fitting of the pneumatic compression device (Aria Free (TM), Aria Health, San Diego CA, USA) and the second focused on evaluating the comfort of the entire system during a 45-min usage period. Both phases were conducted in a monitored clinical environment. Patients aged >= 18 years with a diagnosis of lower limb lymphoedema who had used a pneumatic compression device for >= 3 months were eligible. Patients rated subjective fit, comfort and usability on an 11-point Likert scale (where higher scores indicate better fit/comfort/usability). The truncated cone method was used to infer limb volume before and after therapy in phase 2. Results: Twenty-four patients were screened, and 15 were enrolled (80% female; mean age 62 years); all completed both study phases. Patients rated the garment as easy to set up and fit (median score 6.5), and all reported that the therapy was comfortable (median score 10; p < 0.001 vs. reference score of 6). There was a 1.85% reduction in limb volume after device use for 45 min (p = 0.018 vs. before therapy). No safety issues were identified. Conclusions: The new pneumatic compression device fitted well, was easy to use and reduced leg oedema.
引用
收藏
页码:564 / 571
页数:8
相关论文
共 50 条
  • [21] Results from a comparative study to evaluate the treatment effectiveness of a nonpneumatic compression device vs an advanced pneumatic compression device for lower extremity lymphedema swelling (TEAYS study)
    Barfield, Michael
    Winokur, Ron
    Berland, Todd
    Davis, Sandi
    Ralph, Vicky
    Chatham, Nancy
    Rockson, Stanley
    Maldonado, Thomas S.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2025, 13 (01)
  • [22] Final Analysis (NILE): A Randomized Control Cross-Over Clinical Study Comparing Dayspring: A Novel Wearable Compression Technology to Pneumatic Compression Device in the Treatment of Lymphedema
    Rockson, Stanley G.
    Skoracki, Roman
    Armer, Jane
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (04) : 45S - 45S
  • [23] Pilot Study: Pneumatic Compression Garment Therapy for Postradiotherapy Laryngopharyngeal Edema
    Tritter, Andrew G.
    Spiller, Patrick T.
    Brown, Melanie L.
    Weinberger, Paul M.
    Nathan, Cherie-Ann O.
    ENT-EAR NOSE & THROAT JOURNAL, 2022, 101 (01) : 54 - 58
  • [24] A novel radiofrequency device for the treatment of rhytides and lax skin: A pilot study
    Tay, Yong-Kwang
    Kwok, Colin
    JOURNAL OF COSMETIC AND LASER THERAPY, 2009, 11 (01) : 25 - 28
  • [25] Control of tracheal cuff pressure: a pilot study using a pneumatic device
    Duguet, Alexandre
    D'Amico, Leda
    Biondi, Giuseppina
    Prodanovic, Helene
    Gonzalez-Bermejo, Jesus
    Similowski, Thomas
    INTENSIVE CARE MEDICINE, 2007, 33 (01) : 128 - 132
  • [26] Control of tracheal cuff pressure: a pilot study using a pneumatic device
    Alexandre Duguet
    Leda D’Amico
    Giuseppina Biondi
    Hélène Prodanovic
    Jésus Gonzalez-Bermejo
    Thomas Similowski
    Intensive Care Medicine, 2007, 33 : 128 - 132
  • [27] Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites
    Michael K. O’Reilly
    David Ryan
    Gavin Sugrue
    Tony Geoghegan
    Leo P. Lawler
    Cormac T. Farrelly
    CardioVascular and Interventional Radiology, 2016, 39 : 1765 - 1769
  • [28] Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites
    O'Reilly, Michael K.
    Ryan, David
    Sugrue, Gavin
    Geoghegan, Tony
    Lawler, Leo P.
    Farrelly, Cormac T.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (12) : 1765 - 1769
  • [29] Evaluation of a pilot nurse-led, community-based treatment programme for lymphoedema
    Howell, Doris
    Watson, Marcia
    INTERNATIONAL JOURNAL OF PALLIATIVE NURSING, 2005, 11 (02) : 62 - 69
  • [30] Efficacious Lymphedema Treatment: Impact of an Advanced Pneumatic Compression Device on Health Outcomes and Costs
    Hirsch, Alan T.
    Hoy, Sunday
    Mandic, Pinar Karaca
    CIRCULATION, 2014, 130